RED4 User’s Manuals
RED4 User’s Manuals - Preliminary Version Contents 1 1.1 2 2.1 2.2 2.3 2.4 3 Pin Description .................................................................................................................................. 3 RED4 Pin Description.......................................................................................................................... 3 Operation Method...........................................................................................................................
RED4 User’s Manuals - Preliminary Version Pin Description P17 P12_SCL P11_SDA GND 10 11 12 13 14 15 16 GND GND 8 9 19 P16 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 GND ISP_MODEb CSE NC P15 1 2 3 4 5 6 7 RFIO VCC36 GND P04_SPI_TXD P05_SPI_RXD P06_SPI_CLK P07_SPI_CS 17 18 1 P00_RXD0 P01_TXD0 NC NC NC RESETb SWCLK SWDIO GND GND GND GND GND GND VCC36P VCC36P Figure 1 Pin Description 1.1 RED4 Pin Description No.
RED4 User’s Manuals - Preliminary Version 11 12 P16 P17 13 P12_SCL 14 P11_SDA 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 GND GND GND RF IO GND VCC36P VCC36P GND GND GND GND GND GND SWDIO SWCLK RESETb NC NC NC P01_TXD0 P00_RXD0 31 March 2017 Quasi-bi directional I/O port or External Interrupt 4 Quasi-bi directional I/O port or External Interrupt 5 Quasi-bi directional I/O port I2C Clock The pull-up resistor is always switched on.
RED4 User’s Manuals - Preliminary Version 2 Operation Method Figure 2 Application Circuit 2.1 Power Supply DC power to operate RED4 is separated by 2 kinds. VCC36 is to supply for PR9200 which power range is 3.3 to 3.6 volts, VCC36P is to supply for power amp which power range is 3.3 to 4.2 volts. Total current consumption of RED4 is typically 450mA at 25dBm output power. 2.2 UART The serial interface is assigned with two wires.
RED4 User’s Manuals - Preliminary Version 2.4 GUI Control The RED Utility helps the user to start working with RED DK RFID reader quickly. Follow below steps to run GUI. Windows Start button Program Menu RED Utility_vX.X.X Figure 5 RED Utility_vX.X.
RED4 User’s Manuals - Preliminary Version 2.4.1 Mode Change RED Utility provides two view modes. User can select view mode depending on purpose of use between Basic View Mode and Extended View Mode. Figure 6 Basic View Mode To change View Mode, click the extension button marked red in Figure 6 above.
RED4 User’s Manuals - Preliminary Version Figure 7 Extended View Mode Always use Extended View Mode for measurement. 2.4.2 RED4 Connection If hardware connection is valid, RED utility connect module REDx automatically. If utility cannot connect hardware, please follow below step Click “Connection->Connect” to connect to REDx-DK through USB-to-UART at main window GUI will find the Device and synchronize parameters with REDx module automatically.
RED4 User’s Manuals - Preliminary Version 2.4.3 Hardware Control Click ‘H/W Control Tab.’ To control hardware. 2.4.3.1 Band(Region) Setting To select operating band, band setting should be required. Select band in combo box and click Set button to set operating band in group box ‘Frequency Control.’ 2.4.3.2 Power Class Setting Some countries classify channel number by power class. Click Get button and choose required power class. And then click Set button to set finally. . 2.4.3.
RED4 User’s Manuals - Preliminary Version 2.4.4 Tag Inventory Procedure Click Start button in Tag Information Tab to read UHF RFID tag with RED Utility. Click Start button and Tag’s EPC information is displayed.
RED4 User’s Manuals - Preliminary Version 3 Specification Item Unit 1 2 3 4 Frequency Range Tx Power Spurious Impedance VCC36P DC Power VCC36 Operating Temperature Operating Humidity Power Down Current Idle Active MHz dBm dBm Ω 9 Size mm 24.0 * 24.0 * 3.0 10 Weight g 3 5 6 7 8 Test Condition Specification min Typ. max No. 917.1 mA 926.9 25 US (FCC 15C) 3.3 3.3 -20 0 V °C % uA Remark Active current is measured at 25dBm with 50ohm load 50 3.6 RF I/O 4.2 3.
RED4 User’s Manuals - Preliminary Version FCC Information to User This equipment has been tested and found to comply with the limits for a digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
RED4 User’s Manuals - Preliminary Version In the event that these conditions cannot be met, then the FCC authorizations are no longer considered valid and the FCC ID cannot be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product including this module and obtaining separate FCC authorizations. - This device is intended only for OEM integrators - For OEM integration only – device cannot be sold to general public.