Installation Manual HP15 HP24 HP48 HC24 HA24 HH24 15” SIGNATURE SERIES 24” SIGNATURE SERIES 48” SIGNATURE SERIES C-SERIES ADA-COMPLIANT SERIES 18” SHALLOW-DEPTH SERIES Form No. Z2348 Rev. 04.01.
PERLICK RESIDENTIAL INSTALLATION MANUAL TABLE OF CONTENTS Warranty Information ..................................................................2 Door Information.............................................................................8 Safety Information..........................................................................4 Changing the Door Swing Direction..................................8 Plumbing, Electrical and General Information..............4 Handle Installation......................
PERLICK RESIDENTIAL INSTALLATION MANUAL REMEDY: Perlick will provide the parts and labor necessary to repair or replace (at Perlick’s option) any parts proven to be defective in material or workmanship during the Basic Warranty Period. Perlick will provide the replacement parts, but not the labor, for any parts of the hermetically sealed refrigeration system proven to be defective in materials or workmanship during the Extended Warranty Period.
PERLICK RESIDENTIAL INSTALLATION MANUAL SAFETY PLEASE READ all instructions completely before attempting to install or operate the unit. Take particular note of the DANGER, WARNING and CAUTION information in the manual. The information is important for the safe and efficient installation, operation and care of your Perlick unit. DANGER Indicates a hazard that WILL result in serious injury or death if precautions are not followed.
PERLICK RESIDENTIAL INSTALLATION MANUAL INSTALLATION Unit may tip forward if loaded racks/shelves are all pulled out at the same time. To prevent tipping, and to provide stable installation, the unit must be secured in place with the anti-tip brackets supplied with the unit. The anti-tip brackets, when properly installed, should secure the rear legs/glides to the mounting surface and prevent the unit from tipping forward.
PERLICK RESIDENTIAL INSTALLATION MANUAL PREPARING THE SPACE CAUTION If the unit is to be installed under a countertop, it is recommended that the countertop be supported by a structure other than the unit itself to prevent damage to the unit. 2).
PERLICK RESIDENTIAL INSTALLATION MANUAL TOE PLATE INSTALLATION Once the unit is secured in place, install the louvered toe plate. Secure the plate by snapping the latch into the latch catch on the unit (Figure 5). CAUTION The toe plate must be removed to service the unit. The floor cannot interfere with removal, and the louvered sections must not be covered or obstructed. Obstructions could prevent proper air circulation, which may damage the unit.
PERLICK RESIDENTIAL INSTALLATION MANUAL SHELVING/DRAWER ADJUSTMENTS CAUTION Completely empty shelf or drawer before removing. 1. Pull the shelf/drawer out to its furthest position. Locate the tabs in the middle of both extenders. Lift one tab up while pushing the opposite tab down, and pull shelf/ drawer out (Figure 6). 2. Position each bracket separately. Grasp the middle of the bracket, pull the front end up and out, then forward to remove it. 3. Place bracket at desired location.
PERLICK RESIDENTIAL INSTALLATION MANUAL 5). Using the screws removed in step 3, install the top and bottom hinge brackets from the kit (Fig. 9). Hinge brackets and mounting screws SUPPORT Pull door to the side then lower door Remove hinge pin Figure 7. Door Removal Hinge brackets and mounting screws Figure 9. Hinge Installation Hole plugs Hinge brackets and mounting screws 6). Remove the top and bottom door hinge brackets and the push plunger brackets (Fig. 10). Retain the screws for later use.
PERLICK RESIDENTIAL INSTALLATION MANUAL 7). Remove the front panel from the door assembly by removing the inner mounting screws, 4 per side, from the perimeter of the door assembly (Fig. 11). Rotate the front panel 180°. The top becomes the bottom. Reattach using the same screws and mounting holes. 9). Insert the bearing into the door hinge bracket (Fig. 13). 10). Insert the V-block into the door bottom hinge bracket and attach with the e-clip (Fig. 13). Note the orientation of the V-block.
PERLICK RESIDENTIAL INSTALLATION MANUAL 12). Place the lower V-block into the lower cabinet hinge with the notch parallel to the cabinet (Fig. 15). HANDLE INSTALLATION The handle mounting on the wood CAUTION overlay should be mounted on the overlay only (not the actual door) to avoid damage to the factory door. 1. Handle must be attached to the overlay before mounting the overlay onto the door. Mark the rear of the wood overlay panel with handle fastening locations. 2.
PERLICK RESIDENTIAL INSTALLATION MANUAL WOOD OVERLAY INSTALLATION (FOR -2 AND -4 MODELS) Before beginning installation, check all components for proper fit and finish. WINE RACK TRIM (OPTIONAL) All wine reserve racks come with sleek stainless steel fronts. Unfinished solid hardwood fronts are optional and can be removed and replaced with other wood to match your cabinetry. See Figure 18 and 19 for wine rack face details.
Use and Care Guides, Specification Sheets, Wood Overlay Templates for Doors, Drawers and Grilles, and Corresponding Compliance and Energy Guides are available for download at www.perlick.com/residential-products/service-support. Contact Perlick Customer or Technical Service at 800.558.5592. Customer Service and Technical Service are available business days Monday through Friday from 8 a.m. to 4:30 p.m. CST. 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • info@perlick.com • www.perlick.
Installation Manual for Beer Dispensing Equipment HP15TS/TO HP24TS/TO HC24TB/TO 15” SIGNATURE SERIES 24” SIGNATURE SERIES 24” C-SERIES Form No. Z2349 Rev.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT TABLE OF CONTENTS Dispensing Equipment Installation......................................3 Connecting the CO2 Cylinder.................................................8 CO2 Leak Test.....................................................................................8 Mounting Hole Template...........................................................
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT INSTALLATION OF DISPENSING EQUIPMENT Open the tapping kit box and become familiar with its components. If the dispensing head is going to be mounted on a counter top directly above the refrigerated cabinet, have the counter top pre-drilled using the supplied template on page 9. Make sure that the access hole in the refrigerated cabinet is in line with the counter top holes.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT NOTE: Wash tapping devices thoroughly. Flush beer and faucet lines, as well as the tapping device (keg coupler) with fresh water. 1. Locate the dispensing head , black beer line(s), and hose clamp(s). Slide one end of each beer line onto the stainless steel tubes which protrude out the bottom of the dispensing head and clamp tight. 2. Insert the beer line(s) through the hole in the counter top.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT 4. If installing a two or three faucet system, a CO2 manifold will need to be installed. Locate the red CO2 lines, CO2 manifold and a #10 x 1/2” sheet metal screw. Slide one end of each hose onto the barbed fittings on the manifold and clamp. On the left rear side wall of the beer compartment there is a double row of screws which run vertically. Remove one of the two top screws and discard.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT 7. On the right rear sidewall there is a double column of screws. Remove the center screw. Locate the safety chain and a #10 x 1/2” sheet metal screw from the parts bag. Insert the screw through the closed end link of the chain and tighten in the vacant screw hole. The chain can now be used to secure the tank, preventing damage to the regulator. 8. CO2 tanks are shipped empty and must be filled prior to use.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT 10. Before tapping, make sure the beer faucet is closed. To tap a keg, insert the coupler into the fitting on top of the barrel. Turn the coupler clockwise until it stops (about an 1/8 turn), then push down on the top of the coupler and again turn clockwise until it stops. Your barrel is now open. Open the CO2 valve on the regulator as well as the valve on the manifold if used.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT CONNECTING THE REGULATOR TO THE CO2 CYLINDER 1. Remove the blue plug from the regulator fitting, but do not remove the carbonic washer. 2. Screw regulator onto gas cylinder valve. Tighten with wrench until vertically straight. Be sure that the shut-off valve on the regulator is in the OFF (horizontal) position. 3. Place screw clamp over the end of red line and push onto regulator tail piece. Tighten clamp with a screwdriver. 4.
PERLICK RESIDENTIAL INSTALLATION MANUAL FOR BEER DISPENSING EQUIPMENT perlick.
Use and Care Guides, Specification Sheets, Wood Overlay Templates for Doors, Drawers and Grilles, and Corresponding Compliance and Energy Guides are available for download at www.perlick.com/residential-products/service-support. Contact Perlick Customer or Technical Service at 800.558.5592. Customer Service and Technical Service are available business days Monday through Friday from 8 a.m. to 4:30 p.m. CST. 8300 W. Good Hope Road, Milwaukee, WI 53223 • 800.558.5592 • info@perlick.com • www.perlick.
ATTENTION INSTALLERS THIS IS A FULL SIZE TEMPLATE. PLEASE CONFIRM THAT PRINT DIMENSIONS ARE TO SCALE PRIOR TO INSTALLATION.