TIRE PRESSURE MONITORING SYSTEM All copyright reserved by PDW International © 2019
Notice * Do not watch the device when driving. * This product is for passenger cars only. * Ensure to read through the user manual completely and fully understand the contents before use. * It is recommended that a tyre professional install this product. * This product is an effective to tool to continuously monitor the tyre inflation point; this unit may not be effective during sudden deflation or accidents. * Do not use in conjunction with tyre foam filling products.
Content 1. Display Installation---------------------------------------------------------------1 2. Sensor Installation---------------------------------------------------------------1 2.1 External Sensor Installation----------------------------------------------- 1 2.2 Internal Sensor Installation-------------------------------------------------2 3. Pressure, Temperature, Battery Display----------------------------------- 3 4.
1.Display Installation 1. The unit may be affixed to the dashboard of the car, using the 3M adhesive tape supplied. Ensure that the display does not impair driving vision. 2. First time system boot, hold down the “OK” and “ ” button simultaneously for 3 seconds, until the LCD display comes to life. It is not required to shut down the unit in daily use.The unit will be in sleep mode in 15 minutes if there isn't any vibration detected. 3.
External Sensor Battery Replacement Step 1. Remove the outside cover. 2. Remove the old battery. 3. Install the new battery using battery type CR1632. 4. Replace the outside cover 2.2 Internal Sensor Install (This step should only be done by a tyre professional) a e c b f g a. Remove the tyre from the wheel. b. Remove the old valve from the wheel. c. Ensure the valve hole area is clean. d. Install the internal sensor e. Lock the screw of the sensor on the outside of the wheel. f.
Remarks: 1. Ensure the sensor calibration position when positioning sensor on the car. 2. After installation, ensure to check for leakage from the valve area. 3. Once installed as above, you are now ready to enjoy the added safety of your TPMS unit. 4. This product is a plug-and-play device. Everything has been preset already. Only when it is necessary, can you move to the contents below. 3.
5. Setting The Unit Setting the unit of pressure display 1. Long press “SET” button under the main interface as shown in the below interface. P1 2. Click “SET” button again into the below interface. P2 3. Click “SET” button again into the below interface. P3 4. Click “SET” button again into the unit of pressure interface, as below. P4 Press “OK” button during this interface, either Bar or Psi will flash. Click “SET” button again to switch from the Bar or Psi pressure unit.
6. Pairing *Only required if choosing to change sensor position or singular replacement. 6.1Automatic Lightning Pairing For Internal Sensors (Quick Pairing) The Internal Sensor has automatic lightning pairing function. Each sensor is free to be installed in any tyre. Tyre position will be automatically defined on the display within 2-5 minutes (speed >20km/h). After 5 times of automatic pairing, the wheel position is locked & the automatic pairing function is inactivated for saving battery power.
c. In the pressure display interface (pictured), hold the “SET” button for 3 seconds and release when a “beep” is heard, the LCD will display the flashing left front wheel. d. Click the “OK” button to enter the learning mode (In the example below, we select left front tyre). e. Setup the sensors:Inflate or deflate corresponding tyre (left front in the above example) f. When the display receives a learning signal from the tyre sensor, it will prompt a beep and will show the latest sensor ID number.
The system will automatically jump to the next sensor position. The order of sensor set up is FL—FR—RR—RL g. When all tyres are set up, the display will stop at the rear left position and show its ID. Click “ ” button to exit the setup procedure. Note: During every step you can click the button to cancel the current operation. 6.3 External Sensor Pairing For an external sensor, follow the 6.2 steps to select the wheel on the monitor.
3. Click “SET” button again, to enter the threshold adjustment. (Figure 3) P3 Figure 3 4. Click “OK” button to enter the high-pressure alarm threshold setting. Click “OK”, the value flashes. Click “SET” to change the value. Click “OK” to save the change.(Figure 4) Figure 4 5. Click the “SET” button to set your personal low-pressure alarm threshold. Click “OK”, the value flashes. Click “SET” to change the value. Click “OK” to save the change.(Figure 5) Figure 5 6.
8. Technology Parameters External Sensor Technology Parameters 1. Working voltage: 2.1V-3.6V 2. Working frequency: 433.92MHz 3. Pressure measurement range:0-116Psi 4. Temperature measurement range:-30℃/85℃ 5. Working temperature:-30℃/60℃ Adjustable Metalic Internal Sensor (Not OE) Technology Parameters 1. Working voltage: 2.1V-3.6V 2. Working frequency: 433.92MHz 3. Pressure measurement range:0-116Psi 4. Temperature measurement range:-40℃/105℃ 5.
4. Working frequency: 433.92MHz 5. Display type: LCD 6. Alarm: Symbol, sound, light alarm 7. Working temperature:-30℃/85℃ 9.
10. Guarantee One year of the guarantee period is provided with the conditions as following: a. In addition to the claims under the law and/or contract of sale which arise from material defects, the rights arising from this guarantee are granted by the seller to the customer. b. The product is guaranteed to be free of any defects. Parts that are subject to wear and tear such as batteries, or battery cells are not included in this guarantee.
e. Any defects that occur during the guarantee period should be submitted to the authorized point of service within 2 weeks since they happened. The defect will be remedied by delivery a product identical in construction. Further claims of the customer arising from this guarantee, particularly claims for reimbursement of expenses, reduction, compensation of damages or the right of withdrawal, shall be excluded. f.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.