SAFE BOX USER MANUAL
1. HOW TO USE SAFE BOX SEQ. 1 Function Initial setting 2 LOCK 3 UNLOCK 4 RELOCK Operation Safe box is unlocked entering password "1234" and * with password Press "RESET" button Enter 4 digit password and press “LOCK” button.. Press “RESET” to cancel entering password. * with card Press "RESET" button Place Guest Card on the “LOCK” of the safe box. * With password Safebox is unlocked entering 4 digit password Press ‘RESET” button to cancel entering password..
2. HOW TO SET UP SAFE BOX 2.1 . General functions - 2.2 Safe box operates with card or password. Systems cards for Safe box operation consist of Key Card, System Card, Guest Card and starts with pressing "RESET" button on the safe box. Initial password is set as "1234" and new password is set with 4 digit. Set necessary operational functions on the Setup Card before operating Safe box.
5) Warning signal sounds and “Err2” display on the 7 Segment if the safe box is not locked successfully. 3.1.2 Unlock 1) Enter password and unlocked confirmation sounds and displays ‘OPEN” on the 7 segment. , 2) Unlock the safe box by entering password only, without pressing "RESET".. 3) More than 5 seconds entry time lapse cancels the password input. 4) Pressing “RESET” during password entry cancels the input and have to retry..
4. DISPLAY MESSAGE No 7 Segment Display Function 1 CLOS Lock the safe box 2 OPEN Unlock the safe box 3 bAtt Low battery 4 SEr Operation failure or no settings 5 rtc RTC(Real Time Clock) failure 6 Err1 Wrong password 7 Err2 Wrong operation or hardware failure 8 2910 Disabled Time Count down , e.g.
5. EMGERGENCY MEASURES No. Message 1 Low battery warning sound 2 No power 3 No password entered 4 CLOSE failure 5 OPEN failure 6 Err1 display 7 Ser display 8 7 Segment Display smash 9 Operation disabled Checklist Action Check "bAtt" display on Check battery power Replace batteries Check battery power Check the connection between main and Front panels Check Front Keypad status Confirm Keypad operation buzzer Check connection between Main and Front panels.
6. Safebox SPECIFICATION Part Component MCU Main CPU 8-bit Microcontroller Flash 32KBytes program memory RAM 2KByte SRAM EEPROM 1Kbytes UART 1 programmable Serial Port 32 programmable I/O Lines EEPROM 4kBytes, save 200 history records RF Controller 13.56MHz, ISO 14443A / Mifare RTC(Read Clock) MCU Front Power Spec.
FCC Part 15 Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the ni structions, may cause harmful interference to radio communications.