Users’ Manual Product: Mifare USB Reader Model: MD-150M
Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
MD-150M/MK-1500M User Manual ─ Table of contaens ─ I. MD-150M Specification ----------------------------- 3 II. Communication protocol -------------------------- 5 III. MD-150M command list ------------------------------ 6 IV. MD-150M command description ----------------- 7 NOTE This document is written by SUNION Electronic Corp. SUNION Electronic Corp. reserves the right to change devices or specifications detailed herein at any time without notice.
MD-150M User Manual I. MD-150 M Reader Specification 1 . Reader Specification MD-150M Part Number RF Transmit Frequency 13.
MD-150M/MK-1500M User Manual 3. Dimension 0 70mm 0 26.975mm 孔2mm 30mm 2.575mm 4.275mm 孔2mm 66.
MD-150M/MK-1500M User Manual II.
MD-150M User Manual III.
MD-150M/MK-1500M User Manual IV. USB Reader command description 1. “A0” (Switch to Stand-Alone Operation) Controller send: SOH ID1 “S” ID2 USB Reader responds: SOH ID1 ID2 “s” “A” “A” “0” “0” STX STX ETX data BCC ETX BCC Function description: (1) This function code is able to switch the reader to the “Stand-Alone Operation”. (2) Data response value is "Y" means successful, "N" means failure, duplicate, or no data.
MD-150M User Manual 2. “A1” (Read card and acquire card ID) Controller send: SOH ID1 “S” ID2 USB Reader responds: SOH ID1 ID2 “s” “A” “A” “1” “1” STX STX ETX data BCC ETX BCC Data description: (1) The format of “data” will be: Card type (1 byte) + Card ID (16 byte). (2) Card number is “0” ~ “9” , “A” ~ “F” 。 ex. "00000000003EA88F"。 Function description: (1) Use this function to acquire card ID number through reader.
MD-150M User Manual 3. “E1” (Acquire model name and firmware version) Controller send: SOH ID1 “S” USB Reader responds: SOH ID1 “s” ID2 “E” ID2 “E” “1” “1” STX STX ETX date BCC ETX BCC Data description: (1) The value of “data” will include current firmware version and model name. Function description: (1) Use this function to get model name and firmware version for current reader. Example: Controller send: SOH + "S07E1" + STX + ETX + BCC USB Reader responds: SOH + "s07E1" + STX + "V1.
MD-150M User Manual 4. “E2” ( Reset reader) Controller send: SOH ID1 “S” USB Reader responds: SOH ID1 “s” ID2 “E” ID2 “E” “2” “2” STX STX ETX data BCC ETX BCC Function description: 1. Use this function to reset USB Reader. 2. If “data” value responded is “Y” means the set up is successful, “N” means failed, repeated or no data. 3. CF Card will respond “Y” first then commence reset.
MD-150M User Manual 5. “K0”( Read data in specified page/block) Controller send: SOH ID1 “S” ID2 “K” “0” STX DATA ETX BCC USB Reader responds: SOH ID1 “s” ID2 “K” “0” STX data ETX BCC Data description: 1. “DATA” should be entered as: Card type (1 bytes) + Page/Block number (2 bytes). 2. When Read Mifare Card, Card type is “M ” + Page/Block number;The page/block number is fixed to 2 bytes.
MD-150M User Manual 6. “K1” (Write data into specified page/block) Controller send: SOH ID1 “S” ID2 “K” “1” STX DATA ETX BCC USB Reader responds: SOH ID1 “s” ID2 “K” “1” STX data ETX BCC Data description: 1. DATA should be entered as cars type, page/block number and the information you want to input, just as follow: Card type (1 byte) + Page/block number (2 bytes) + Information (16 bytes). 2.
MD-150M User Manual 7. “K2” (Choose want to use Key) Controller send: SOH ID1 “S” ID2 “K” “2” STX DATA ETX BCC USB Reader responds: SOH ID1 “s” ID2 “K” “2” STX data ETX BCC Data description: 1. “DATA” should be compare with A,B Key, sector number you want to lock, just as follow: Card type (1 byte) + Page/block number (2 bytes) 2. Card type should be entered as: “M” for Multi-Page. 3. The range of page/block number is different in different card type. 4.
MD-150M User Manual 8. “K3” (Set A,B Key value of 32 Sector groups ) Controller send: SOH ID1 “S” ID2 “K” “3” STX DATA ETX BCC USB Reader responds: SOH ID1 “s” ID2 “K” “3” STX data ETX BCC Data description: 1. DATA should be entered as cars type, Sector group and the information you want to input, just as follow:Card type (1 byte) +[Sector group(2 bytes)]+ Information (12 bytes). 2. The range of Sector group of Reader is "01"- "20"(HEX ) 32 groups altogether.