2018/11/15 Particle Datasheets | Xenon datasheet DOWNLOAD PDF Functional description Overview The Xenon is a low cost mesh-enabled development board that can act as either an endpoint or repeater within a Particle Mesh network. The Xenon is mesh only and designed to function as the endpoint of your IoT network. It is based on the Nordic nRF52840 and has built-in battery charging circuitry so it’s easy to https://docs.particle.
018/11/15 Particle Datasheets | Xenon datasheet connect a Li-Po and deploy your local network in minutes. The Xenon is best for connecting sensors, motors, pumps, valves, and points of datainterest. Pair it with an Argon or Boron gateway to get all that great data into the Device Cloud. Features Nordic Semiconductor nRF52840 SoC ARM Cortex-M4F 32-bit processor @ 64MHz 1MB flash, 256KB RAM IEEE 802.15.
2018/11/15 Particle Datasheets | Xenon datasheet Power USB PORT The USB port is the easiest way to power up the Xenon. Please make sure that the USB port is able to provided at least 500mA. Power from the USB is regulated down to 3.3V by the on board Torex XC9258A step-down regulator. VUSB PIN The pin is internally connected to the VBUS of the USB port. The typical output should be around 4.5 to 5 VDC when the device is plugged into the USB port and 0 when not connected to a USB source.
2018/11/15 Particle Datasheets | Xenon datasheet If you want to make your projects truly wireless, you can power the device with a single cell LiPo/Lithium Ion (3.7V). The Xenon has an on board LiPo charger that will charge and power the device when USB source is plugged in, or power the device from the LiPo alone in the absence of the USB. NOTE: Please pay attention to the polarity of the LiPo connector.
2018/11/15 Particle Datasheets | Xenon datasheet powering over this pin, please connect the ENABLE pin to GND so that the on board regulator is disabled. Antenna There are two options for the Mesh antenna on the Xenon. It comes with an on-board PCB antenna which is selected by default in the device OS and a u.FL connector if you wish to connect an external antenna. If you wish to use the external antenna, you'll need to issue an appropriate command in the firmware.
2018/11/15 Particle Datasheets | Xenon datasheet bootloader, device OS, or the user firmware using any standard SWD tools including our Mesh Debugger.
2018/11/15 Particle Datasheets | Xenon datasheet Pin markings https://docs.particle.
2018/11/15 Particle Datasheets | Xenon datasheet Pinout diagram https://docs.particle.
2018/11/15 Particle Datasheets | Xenon datasheet You can download a high resolution PDF version of the pin out here. Pin description Pin Description Li+ This pin is internally connected to the positive terminal of the LiPo battery connector. VUSB This pin is internally connected to the USB (+ve) supply. 3V3 This pin is the output of the on-board 3.3V regulator. GND System ground pin. EN Device enable pin is internally pulled-up. To disable the device, connect this pin to GND.
2018/11/15 Particle Datasheets | Xenon datasheet Pin Description D2-D8 These are generic GPIO pins. D2-D8 are PWM-able. A0-A5 These are analog input pins that can also act as standard digital GPIO. A0-A5 are PWM-able. LED status System RGB LED For a detailed explanation of different color codes of the RGB system LED, please take a look here.
2018/11/15 Particle Datasheets | Xenon datasheet conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. Recommended operating conditions Parameter Symbol Min Typ LiPo Battery Voltage VLiPo +3.3 +4.4 V Supply Input Voltage V3V3 +3.0 +3.3 +3.6 V Supply Output Voltage V3V3 +3.
2018/11/15 Particle Datasheets | Xenon datasheet Parameter Symbol Input high voltage Conditions Min Typ Max Unit VIH 0.7*3.3 -- 3.3 V Input low voltage VIL 0 0.3*3.3 V Current at GND+0.4 V, output set low, high drive IOL,HDL V3V3 >= 2.7V 6 10 15 mA Current at V3V3-0.4 V, output set high, high drive IOH,HDH V3V3 >= 2.
2018/11/15 Particle Datasheets | Xenon datasheet Mating connectors The Xenon uses two single row 0.1" pitch male header pins. One of them is 16 pin while the other is 12 pin. It can be mounted with matching 0.1" pitch female headers with a typical height of 0.335" (8.5mm). When you search for parts like these it can be difficult to navigate the thousands of parts available online so here are a few good choices for the Xenon: Description MFG MFG Part Number 16-pin 0.1" (2.
2018/11/15 Particle Datasheets | Xenon datasheet Schematic The complete schematic and board files are open source and available on Particle's GitHub repository here. Power https://docs.particle.
2018/11/15 Particle Datasheets | Xenon datasheet nRF52840 SPI FLASH Interfaces https://docs.particle.
2018/11/15 Particle Datasheets | Xenon datasheet Ordering information Xenons are available from store.particle.io in single quantities. Qualification and approvals Model Number: XENN RoHS CE FCC ID: 2AEMI-XENN IC: 20127-XENN Product Handling ESD Precautions https://docs.particle.
2018/11/15 Particle Datasheets | Xenon datasheet The Xenon contains highly sensitive electronic circuitry and is an Electrostatic Sensitive Device (ESD). Handling Xenon without proper ESD protection may destroy or damage it permanently. Proper ESD handling and packaging procedures must be applied throughout the processing, handling and operation of any application that incorporates Xenon. ESD precautions should be implemented on the application board where the Xenon is mounted.
2018/11/15 Particle Datasheets | Xenon datasheet The u.FL antenna connector is a very fragile piece of hardware ( and is fancy too with all the gold plating). The connector was not designed to be constantly plugged and unplugged. Care must be taken not to put stress on it at any time (yes, swinging the Xenon by the antenna is a very bad idea, this is not your cat). The antenna pin is also the most static sensitive and you can destroy the radio with improper handling.
2018/11/15 Particle Datasheets | Xenon datasheet very easily toggle digital pins, take analog and digital readings and drive variable PWM outputs. The bootloader allows you to easily update the user application via several different methods, USB, OTA, Serial Y-Modem, and also internally via the Factory Reset procedure. All of these methods have multiple tools associated with them as well.
18/11/15 Particle Datasheets | Xenon datasheet End equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product.
2018/11/15 Particle Datasheets | Xenon datasheet Canada certification number of the module, preceded by the words “Contains transmitter module”, or the word “Contains”, or similar wording expressing the same meaning, as follows: Contains transmitter module IC: 20127-XENN This End equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.
2018/11/15 https://docs.particle.