Instructions / Assembly

F3502
Installation & Operating Instructions for the
Owner’s Installation ,Manual
WARNING:SHUT POWER OFF AT FUSE OR CIRCUIT BREAKE
R
THANK YOU FOR YOUR PURCHASE
SAFETY RULES
SKU Rated Voltage Light CCT.Rated power(motor)
110-120V AC
E12 3x40W(MAX)EXCLUDE
34W
Thank you for purchasing this quality product. To ensure correct function and safety, please read and save all
instructions before using the product
1. Mounting Bracket x1
2. Canopy screws x 2
3. Canopy x 1
4. Downrod&hanger ball x 1
5.
Bolt x 1
6. Coupling cover x 1
7.
8.Lock pin x 1 
9.Top housing x 1 
Blades x 3
10.
11.Fan motor assembly x 1
12.Base plate x 1
13.Lamp shade x 1
14.Light pan x 1
17.
18.Wood screws x 4
19.Expansion screw x 2
20.Plastic anchor x 4
21.Balance tapes x 2
Crystal chain x 37
22.Remote control x 1set
Crystal bead x 37
BEFORE INSTALLATION
Unpack your fan and check the contents.You should have followings:
CAUTION
READ INSTRUCTIONS CAREFULLY FOR SAFE
INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT
A QUALIFIED ELECTRICIAN
1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box
2. All wiring must be in accordance with the National Electrical Code and local electrical codes. Electrical
installation should be performed by a qualified licensed electrician.
3. WARNING: To reduce the risk of electrical shock and fire, do not use this fan with any solid-state fan speed
4. WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked "Accep-
table for Fan Support of 45kg (99.12 lbs.) Or Less" and use mounting screws provided with the outlet box.
Most outlet boxes commonly used for the support of light fixtures are not acceptable for fan support and may
need to be replaced. Due to the complexity of the installation of this fan, a qualified licensed electrician is
The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum
of 45KGS. Use only UL Listed outlet boxes marked FOR FAN SUPPORT.
The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor.
Avoid placing objects in the path of the blades.
To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning
9. Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened
cloth will be suitable for most cleaning.
10. After making electrical connections, spliced conductors should be turned upward and pushed carefully up
into the outlet box. The wires should be spread apart with the grounded conductor and the equipment-
11. Electrical diagrams are for reference only.
12.
The fan is suitable for indoor use only.
13. Please do not use the fan in a specific environment like high temperature environment,
high radistion environment,lampblack or other abnormal use environments.
TECHNICAL INFORMATION
INSTALLING THE FAN
Tools Required: Phillips screwdriver, Pair of pliers, straight slot screwdriver, adjustable wrench, step ladder, and wire cutters.
INSTALLLING THE MOUNTING BRACKET
The ceiling fan must be installed in a location so that the blades are 12”( 300mm) spacing from the tip of the blade to the nearest objects or walls. When hanging the Fan REMEMBER to
turn off the power. Follow the instruction below to hang your fan properly:
NOTE:Hanger after the installation must be able to withstand the weight of 45kg or more
1. For concrete ceiling, drill two holes in
the ceiling and secure the mounting
bracket to the ceiling with two
Φ0.32”(8mm)distance between the
two holes should be appropriate
expansion screws, flat washers,nuts
provided and tighten with a spanner.
2. For wood ceiling, Secure the
mounting bracket to the ceiling is
capable of carrying a load of at least
100lbs(45kgs) with two long mounting
screws and washers provided. Be sure
at least 0.12”(30mm) of the screw is
threaded into the support.
3. For installing to outlet box, secure the outlet box
directly to the building structure. Use appropriate
fasterners and building materials. The outlet box and its
support must be able to fully support the moving weight
of the fan(at least 100lbs). Use a UL listed metal outlet
box. Do not use a plastic outlet box. Figure 1& 2
examples to mount the outlet box.
4. Refer to the Fig. in right for mounting
when the ceiling is angled max. 15
degree angle.
grounding conductor on one side of theoutlet box.
before beginning.
control device.
strongly recommended.
the fan.
F3502
15.
16. Garnish nuts x3  
Canopy cover x 1
1
10
11
7
9
2
3
4
6
5
8
12
13
16
14
15
17
2
4
8
hr
1
2
3
22
18
19 20
21
BEFORE INSTALLATION
Unpack your fan and check the contents.You should have followings:
1. Mounting Bracket x 1
2. Canopy screws x 2
3. Canopy x 1
4. Downrod&hanger ball x 1
5.
Bolt x 1
6. Coupling cover x 1
7.
Lock pin x 18.
Top housing x 19.
Blades x 310.
Fan motor assembly x 111.
Base plate x 112.
Lamp shade x 113.
Light pan x 114.
Wood screws x 4
15.
Expansion screw x 2
16.
Plastic anchor x 4
17.
Balance tapes x 2
18.
Remote control x 1set
19.
Crystal chain x 37
20.
Crystal bead x 37
1
10
11
7
9
2
3
4
6
5
8
12
13
16
14
15
17
2
4
8
hr
1
2
3
22
18
19 20
21
F3502
Installation & Operating Instructions for the
Owner’s Installation ,Manual
WARNING : SHUT POWER OFF AT FUSE OR CIRCUI T BREAKER
Canopy cover x 1
21.
22.
Garnish nuts x 3
All rights reserved. Made in China All rights reserved. Made in China