V2 CLESS M User Manual V2 CLESS M – USER MANUAL 1
FOREWORD INSTALLATION. We recommend you to read these instructions very carefully. They are included with your V2 Cless Reader in order to explain its installation. USE. Once it is installed and equipped with the application you case use your V2 Cless reader. GUARANTEE AND SAFETY. In order to benefit from the guarantee on this equipment and in order to follow the safety instructions, only authorized person shall entrust assembly or disassembly procedures and installed the reader. CONTENTS 1.
1.SAFETY INSTRUCTIONS A- In order to power down your V2 CLess : Disconnect the V2 Cless power supply block from the electric power supply network B- Electrical power supply a. Only use Parkeon Contacless reader cable b. Only use Parkeon antenna cable with it’s Ferrite for EMI protection c.
2.UNPACKING. PRODUCT CONTENTS Carefully preserve the packaging of the V2 Cless and the antenna. It must be re-used whenever the reader is shipped.
3.
Diagram of connection cess Only 4 different antennas can be integrated ( ref ELM_404304686/ ELM_1000004108 / CAR_10000000081 / CAR_1000006460) Contactless reader cable Power supply and communication of contactless reader with the card connector is made via a cable labeled "CLESS" and "PC" - "POWER CLESS".
Antenna cable The antenna is connected to the contactless reader by means of a cable with an angled MCX coaxial connector and an angled SMB coaxial connector.
4.INSTALLING THE V2 CLESS 4.1 Module Tools required: Philips head screwdriver Time required for the intervention: 2 min Other components to remove/Preliminaries: switch off the power to the devices in EMS mode or with the button on the front of the CPU. Disconnect the antenna cable and the contactless reader cable. Slightly unscrew the two fastening screws with a Philips head screwdriver. Unscrew the two bolts holding the drive module.
4.2 Antenna Connect the antenna cable. Put it on the four screws.
5.INSTALLING AND REMOVING SECURITY ACCESS MODULES Tools required: key 8 Time required for the intervention: 8 + 3 min Unscrew the screw that locks the access trap SAMs. Rotate the trap to access locations of SAMs. Locking Screw SAMs slot Contactless reader Access trap SAMs Remove the SAMs their modules. Set new in empty slot positions. Replace the contactless reader. Connect the cables on the previous contactless reader. Press the power button device of the CPU.
6. DAILY USE No specific care shall be done.
7. V2 CLESS CHARACTERISTICS Physical Characteristics Mass : approximately 400g without cable Dimensions : approximately 166x79x35 mm (LxWxH) Standards See “EC standard compliance marking” in appendix Operating conditions Class II equipement Electric supply network Max. consumption : 12VDC +/- 10% : 0.5 A Ambiant temperature Max.
8.
© Copyright 2010 Parkeon. All rights reserved. Parkeon reserves all proprietary rights relating to the contents of this document.Parkeon Reserves all rights over usage, reproduction, representation, marketing, translation, adaptation Or modification, and generally all rights over present and future utilisation by any means, for any Purpose and in any territory, throughout the period of protection. All use of the contents of this Document requires the prior written permission of Parkeon.