User's Manual

FIREMASTER IV "
MillenniumThree
" radio shooting system User’s manual
2 . "TESTING" ICON
This mask allows to select the functions for SET, MODIFY and CHECK all
parameters of the Remote Units active at the same moment.
Using keys F1 and F2, one can select one of the two possible operating modes:
"TEST LINE" and "TEST UNIT". With "SEL" F6 it will be open the mask
relative to the selected icon.
2.1
"TEST LINE" ICON
This icon selects the menu of SINGLE LINE TEST. This operating mode is the
same used in the previous version FIREMASTER II and FIREMASTER III: it is
possible to "call" one line at the time and the following parameters will be returned:
the number of the Remote Unit containing this line, the sequence of that line, the
ohmic resistance of the line, the batteries voltages, the level of the radio signals both
received and transmitted and, if the sequence is of "timed" type, also the time value.
The sequence and time parameters can be modified at any time and the
variations will take place immediately being stored in the memory of the remote
unit.
NOTE: any modification made with this function, WILL BE NOT COPYED in
the memory of the Base Unit and thus the "SHOW" data eventually downloaded
from a PC with the serial line, will REMAIN UNCHANGED. The user must have
well clear in mind as, if the show has been created on a PC using a commercial
program of show management and then loaded in memory, it will be mandatory to
verify, test and modify it using exclusively the functions of "SHOW EDITING",
"SHOW VERIFY", "IMPORT/EXPORT" and "UNITS PROGRAM" providing
21