SYSTEM FIREMASTER III "Millennium" RADIO-CONTROLLED SYSTEM FOR REMOTE SHOOTING OF PYROTECHNIC SHOWS CONTENTS Paragraph 1. 1.1 1.2 1.2.1 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2. 2.1 2.1.1 2.2 2.3 2.3.1 2.3.2 3. 3.1 3.2 3.3 3.3.1 3.3.2 3.3.3 3.3.4 3.3.5 3.3.6 3.3.7 4. 4.1 4.2 4.3 4.4 4.5 4.5.1 4.5.2 4.6 4.6.
FIREMASTER III "Millennium" radio shooting system 4.6.2 RS-485 4.6.3 RS-232 5. FM3K-BP Battery Pack 5.1 Front-panel description 5.2 General Description 5.3 Operation description 5.3.1 TEST 5.3.1.1 TEST (Unit connected to mains) 5.3.1.2 TEST (Unit stand-alone) 5.3.2 Test conditions 5.3.3 Battery test before charging 5.3.4 Charge 5.3.5 Battery test after charging 5.3.6 Error conditions listing 5.4 Batteries 5.5 Internal batteries replacement 5.6 Batteries installations inside the FM3K-BP Battery Pack 6.
FIREMASTER III "Millennium" radio shooting system 1. COMMAND UNIT MODEL TX 2000 - A BASE STATION MODEL TX2000 - A 1.
FIREMASTER III "Millennium" radio shooting system 1.2 User’s manual Front-panel commands description 1. FUNCTION Keys F7 - F11 - the specific function of these keys varies with the mask actually displayed on the screen and it is described by means of a specific graphic icon placed near the key. 2. FUNCTION Keys F1 - F6 - the specific function of these keys varies with the mask actually displayed on the screen and it is described by means of a specific graphic icon placed near the key. 3.
FIREMASTER III "Millennium" radio shooting system 4 User’s manual
FIREMASTER III "Millennium" radio shooting system User’s manual 1.2.1 Instrument and connectors description 1. RS-232 standard SERIAL Port. Male DB-9 connector. This port is used to connect the TX2000 module to a PC. For the connection DO NOT USE a COMMERCIAL RS-232 cable, but the ones supplied with the system. In detail: - For all the download and upload functions of pyrotechnic show data already generated on a PC with EXTERNAL SOFTWARE (e.g.: PyroMotion, FIREONE, etc.
FIREMASTER III "Millennium" radio shooting system - User’s manual Only to download eventual program updates, patches and custom-made releases supplied directly by Parente Fireworks, use the RED marked cable (for this function detailed instructions will be supplied for any specific case) 2. RS-485 standard SERIAL Port. Female DB-9 connector.
FIREMASTER III "Millennium" radio shooting system User’s manual 1.3 Operation 1.4 Base Station TX2000 usage procedure Turn the key selector on SAFE position: the display light will turn on and the graphic logo "FIREMASTER III PLUS" will appear. The logo will remain 10 seconds and the main menu mask will be automatically displayed. Pressing any key before the 10 seconds period is elapsed, the main menu mask will be immediately displayed.
FIREMASTER III "Millennium" radio shooting system User’s manual The selection of the proper icon is made with F1 and F2 keys: the six icons will be evidenced in sequence. The F6 "SEL" key "opens" the highlighted icon. Inside this mask, all other keys are INACTIVE. 1.5 "SHOW MANAGEMENT" Mask description "SHOW VERIFY" Icon. It can be used only if one is operating using a show created externally on a PC and already loaded on the TX2000 Base Unit memory.
FIREMASTER III "Millennium" radio shooting system User’s manual "TESTING" Icon. This icon allows access to the most important functions of the FIREMASTER III SYSTEM. By means of these functions the shooter can verify, modify and program all the remote units creating a complete show on the field or at the company.
FIREMASTER III "Millennium" radio shooting system - 1.6 User’s manual The lower data bar (always present in all masks) shows the following data: time, date, the internal system battery voltage and the user's code (user's #). The “user's #” is the system owner personal code number (4 digits). Every user has a different code, generated at the moment of the first purchase of the System. This code must match with the corresponding one on all Remote Units.
FIREMASTER III "Millennium" radio shooting system 1.7 User’s manual "SYSTEM SETUP" Icon Selecting this icon the following three functions can be accessed: - Real-time clock setup - Date setup - Transmission mode setup REAL-TIME CLOCK SETUP: with "UP" and "DOWN" keys (F1 and F2), select the "TIME" bar. Type on the keyboard the new value for TIME (format hh .mm) and press ENTER. The TIME will be immediately updated to the new value. Seconds will be put to 00 automatically.
FIREMASTER III "Millennium" radio shooting system User’s manual remaining units NOT connected by cable, will continue to operate using the RADIO link. "CABLE" MODE: only the data relative to the FIRE COMMANDS, will be sent to the remote units using THE CABLE CONNECTION ONLY (RS-485 port).
FIREMASTER III "Millennium" radio shooting system User’s manual "new generation" Units) by the "old" type Units, it will be necessary to insert in the "boxes" displayed in this mask, THE NUMBERS OF ALL REMOTE UNITS of "old generation" type. The System will be able to automatically recognize these units when the TEST or PROGRAMMING signals are issued. PRACTICALLY: the User will define once for all the "old generation" type Units and will type the corresponding numbers in the cells of this mask.
FIREMASTER III "Millennium" radio shooting system User’s manual Once the numbers of the "old generation" type Units, will be correctly entered, press the F6 "SAVE" key to confirm and leave the mask using F5 "BACK".
FIREMASTER III "Millennium" radio shooting system 1.9 User’s manual "TONE GENERATOR" Icon Selecting this icon, one will access the function for the GENERATION of a FIRE COMMAND coded as an audio tone (AFSK) available to the "SYNCHRO" connector. This signal is intended to be recorded on the musical base in order to obtain a synchronism with the accompanying music during the pyromusical shows. (For more details, see the relative chapter).
FIREMASTER III "Millennium" radio shooting system User’s manual time the time counter can be STOPPED ("STOP" F2), RESET TO ZERO ("RESET" F3) and RE-STARTED ("RUN" F1) using the relative function keys. As usual the "BACK" key allows to exit the function and to return to the previous mask. NOTE: the time counter values are given for INDICATION PURPOSE ONLY and can be used to help the operator to issue the synchronism tones at the exact moment.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 2 . "TESTING" ICON This mask allows to select the functions for SET, MODIFY and CHECK all parameters of the Remote Units active at the same moment. Using keys F1 and F2, one can select one of the two possible operating modes: "TEST LINE" and "TEST UNIT". With "SEL" F6 it will be open the mask relative to the selected icon. 2.1 "TEST LINE" ICON This icon selects the menu of SINGLE LINE TEST.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni equivalent data stored inside the base Unit (containing the "image" of the whole show). If, on the contrary, the show is managed "manually" using the functions of the mask "TEST LINE" or "TEST UNIT", all the programming operations must be performed inside these masks and the Base Unit TX2000 will NOT MAINTAIN ANY MEMORY OF THE SHOW (just as in the previous FIREMASTER II SYSTEM).
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 2) The Remote Unit selected "answers back" and the data will be printed on the LCD screen. In the example below: the selected line is NOT connected or the line resistance is greater than 99 ohm and the sequence of that line is of "no timed" type.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni NOTE: when the "WARNING" icon appears, the system can be still used as usually. One should anyway consider as the system is working near to the lower limit of its possibilities and thus some problems more or less severe could be encountered such as: firing failures, no response from the Remote Unit, errors reading data, etc.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni verify the firing line if the resistance value is too far from the expected value with reference to the number of connected squibs and the cable length. If otherwise THE PARAMETERS OF THAT LINE MUST BE MODIFIED (new programming), then the operation will be as described in the next chapter. 2.1.
Sistema FIREMASTER III "Millennium" - Manuale di istruzioni press F5 "TIME INCREMENT": on the middle of the LCD screen the mask below will appear. Type now the VALUE FOR THE CONSTANT TIME INCREMENT spacing the shots of the sequence (1.00 or 100 meaning ONE second) and press ENTER to confirm.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni Proceed now INCREASING the LINE value with F11 and press the "AUTO INCREMENT" key on the main keyboard: the time value will be automatically incremented by the selected quantity and the sequence, if not otherwise set, will be automatically timed. Continue the same way till the sequence end. REMOVE THE TIMING FROM A SEQUENCE ALREADY TIMED.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni When the "0" key on the numeric keypad will be pressed, a RESET command will be issued to the selected Remote Unit and all 24 lines will return to the "normal" mode (no timing). On the completion of this operation the message "OK, DONE!" will be issued as confirm. Pressing ANY OTHER KEY instead (ANY), the operation will be cancelled and the function terminated. 2.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 1) Keys 0 to 9 are used to enter numeric values for the parameters requiring so. Letters are used to insert literal strings for some functions requiring so (password, show description, etc.) 2) The "CE" key (Clear Entry) is used to cancel a numeric value just after it has been typed and before it is confirmed. 3) The "ENTER" key is used to confirm the numeric value just typed in or to send a command to the Remote Units. 4) The ".
Sistema FIREMASTER III "Millennium" 2.3 Manuale di istruzioni "TEST UNIT" ICON The high-resolution graphic display of the new FIREMASTER III SYSTEM, allows to display at the same time a lot more information than it was possible on the previous version. The "TEST UNIT" function in particular, uses this possibility to display, WITH A SINGLE COMMAND, the complete situation relative to all 24 lines of a selected Remote Unit.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni From inside the mask "TEST MENU" select the "TEST UNIT" icon: the mask "TESTING UNIT #…" will appear Because a specific Remote Unit has been not selected nor checked yet, by default, it will be shown the 12 first lines situation of Remote Unit #1. All parameters are still unassigned or set to ZERO. Press the key F9 "UNIT" to select, among the ACTIVE Remote Units, the one to be checked.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni If the Remote Unit shouldn't reply immediately, two more attempts of connection will be automatically made: after that an error message will be issued.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni In the example above, the Remote Unit #3 has been checked and it sent back all data contained in its memory : sequence (SEQ) and relative time (TIME) for all lines eventually defined as "timed sequence".
Sistema FIREMASTER III "Millennium" Manuale di istruzioni To REPEAT the call to the same Remote Unit, it will be sufficient to press F7 "QUERY". The operation can be repeated as many times as needed and can be used to control in real time an eventual variation of the working parameters of the Remote Unit (line resistance, battery voltage, radio signals intensity). To call a different Remote Unit, it will be necessary to use F9 "UNIT" as previously described. 2.3.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni CONNECTED, are regarded as OPEN CIRCUIT and the corresponding message "OPEN" will be displayed in the cell RES - VSYS: this is the value, measured in volt, of the SYSTEM battery (microcontroller, peripherals, radio) on the Remote Unit. The measurement is made EACH TIME the Unit or a specific line is called. If the voltage of this battery falls down a preset value, the error message "FAULT" will be displayed.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 2.3.2 HOW TO REMOVE ALL TIMED SEQUENCES FROM THE SAME REMOTE UNIT Press the F9 key "UNIT" followed immediately by the F8 key "NO TIME": the following mask will appear When the "0" key on the numeric keypad will be pressed, a RESET command will be issued to the selected Remote Unit and all 24 lines will return to the "normal" mode (no timing). On the completion of this operation the message "OK, DONE!" will be issued as confirm.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 3. "FIRE" FUNCTION 3.1 FOREWORD All functions just described have been used with the key switch selector of the Base Unit TX2000 in position "TEST-SAFE". In this operating mode it is TOTALLY INHIBITED the transmission of a particular code regarded by all Remote Units as a FIRE COMMAND. All Remote Units have thus the batteries powering the lines, PHYSICALLY DISCONNECTED.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 3.2 THE "FIRE"MASK At any moment and from inside any mask of the "SAFE-TEST" function, it is possible to switch to the "FIRE" mode simply placing the rotary keyswitch on this position. The following mask will be immediately displayed: By default the following operating modes will be selected: - SHOW TIME: set to ZERO, waiting for the first fire command. TIME TO NEXT: not active in MANUAL MODE.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni Pressing only one pushbutton (indifferently ARM or FIRE), the system will "arm" itself and the FIRE command will be immediately sent when the other button will be pressed. To proceed with the NEXT SHOT, it is necessary to release first BOTH BUTTONS.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 3.3 FIRING OPTIONS The SYSTEM FIREMASTER III can operate in different modes in order to match any show characteristics. The different firing modes can be selected by the operator inside the "FIRE" mask and immediately before the show begins.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 3.3.1 MANUAL MODE This mode has been described at the beginning of the chapter and quoted as an example. This operating mode is selected using key F3 "MAN". Should be also active the "SHOW" mode, the latter must be cancelled using the key F1 "SHOW" (used as toggle).
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 3.3.3 MANUAL "SHOW" MODE AVAILABLE AFTER JUNE 1st 2004 3.3.4 AUTOMATIC "SHOW" MODE AVAILABLE AFTER JUNE 1st 2004 3.3.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 3.3.6 OPTIONS IN "SHOW" MODE For the three "SHOW" modes, a further option is available: this option is shown in the "FIRE MODE!" mask. This is the possibility of EXCLUSION of one or more "groups" of fireworks previously defined.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 3.3.7 OPERATION NOTES WHEN IN "FIRE MODE!" When the keyswitch is turned on the "FIRE" position, the transmitter of the Base Unit TX2000, immediately starts to send automatically a special code ("watch dog"). This code is sent at regular intervals of about 5 seconds: the "TX R.F." green LED will flash shortly each time.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 4. REMOTE UNITS RX24-B (RECEIVERS) 4.
Sistema FIREMASTER III "Millennium" 4.2 Manuale di istruzioni COMMANDS DESCRIPTION 1. BINDING POSTS with quick-connection feature. Nickel-plated metal. Used to connect the squibs lines. 2. INDIVIDUAL numbering for each line. The RX24B Remote Units are numbered in PROGRESSION and the same for the outputs of every single line. E.g.: the Unit N°1 has the outputs numbered 1 to 24, Unit N°2 has its outputs numbered 25 to 48 and so on. 3.
Sistema FIREMASTER III "Millennium" • Manuale di istruzioni The VARIATION between the OPEN-VOLTAGE and the measurement UNDER LOAD of the LINE battery is more than 10% In the cases above the SYSTEM can be used normally but one must take into account as the batteries are NOT FULLY EFFICIENT and they must be checked and re-charged as soon as possible. Connecting the RS-232 port of the Remote Unit to a PC with any communication program running (Telix, Hyperterminal, etc.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni microcontroller system for the controlled charging management and the mains power supply. NOTE: the Battery Packs are all IDENTICAL each other and can be interchanged without limitations both among the the various RX-24B Units and the TX-2000 base Unit. (See the specific chapter for details). 15. RX24-B Remote Unit.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni All Remote Units are individually marked with a progressive number on the front-panel Each Unit has 24 lines individually marked: Unit number ONE has lines 1 to 24, Unit TWO from 25 to 48 and so on for all existing Units. The batteries can be charged removing the Battery Pack from the Unit itself and connecting it to a mains receptacle (230V 50Hz or 115V 60Hz optionally).
Sistema FIREMASTER III "Millennium" 4.4 Manuale di istruzioni Power ON procedure Main switch to “ON” The green LED flashes quickly (all lines are tested in sequence) The green LED pauses (the fire battery is now controlled) If all test are passed, the green LED remains lit permanently: the Unit is READY TO OPERATE Should a test fail, the yellow LED “FAULT” will turn ON.
Sistema FIREMASTER III "Millennium" 4.5 4.5.1 Manuale di istruzioni Units Field Usage Protection 1) The Remote Units on field are subject to burning fallout with consistent risk of permanent damage of the plastic front-panel.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 4.5.2 Antennas 1) The antenna supplied with the FIREMASTER III "Millennium", is INTEGRAL WITH THE INSTRUMENT and it is used the same type both for the Base Unit TX2000 and the Remote Units RX24-B. These antennas are whip type in λ/4 resonating at 40,700MHz. The antenna is realized completely in fiberglass, and it is very flexible and fire resistant. The connection to the Unit is pivot-type one with wing nut.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 1) Connection with wing nut 2) Fiberglass whip antenna 49
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 4.6 Connections 4.6.1 Firing lines The RX24-B Remote Units are provided with 24 couples of binding posts to connect 24 independent firing lines. Each line is powered by the internal batteries of the Unit itself.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 27 −2=7 3 From the above calculations, it will be possible to connect IN SERIES up to 7 igniters of this type with a 100% warranty of ignitions. These calculations are very prudential and theoretical: in practice it would be possible to connect in series a lot more igniters (giving up some safety margin).
Sistema FIREMASTER III "Millennium" Manuale di istruzioni When the connection by serial RS-485 line is used, all the Units (TX2000 and RX24B) must be connected each other with a TWO-WIRE cable (available upon request). It can be used indifferently a "STAR" connection or a "CHAIN" connection".
Sistema FIREMASTER III "Millennium" Manuale di istruzioni The connectors wiring must be realized following the diagram below: 4.6.3 RS-232 The RS-232 interface, installed both on the Remote Units RX24B and the Base Unit TX2000, can be used for three different purposes: A) Download of data concerning a pyrotechnic show created with specific software (supplied by the User).
Sistema FIREMASTER III "Millennium" Manuale di istruzioni The (A) case is the most common one and it is used to "load" in the internal memory of the Base Unit TX2000 the data concerning a pyrotechnic show created externally on a PC using a dedicated software commonly available on the market (PyroMotion, FireOne, etc.).
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 5.0 FM3K-BP BATTERY PACK 5.1 FRONT- PANEL DIAGRAM 1) Batteries placement inside the container. 2) "CHARGE" GREEN LED it turns ON when the charger is connected to the mains. 3) "TEST OK - FAULT" bi-color LED (RED-GREEN): it indicates a condition of "battery test running" (GREEN), or an "ERROR" condition (RED).
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 7) "TEST" key: if it is pressed for at least one second, the automatic check of the status for all batteries of the System, is activated. If the battery Pack is NOT connected to the mains, the status test can be carried-out anyway, but the "TEST" key must be held down as long as the test takes place.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 5.2 GENERAL DESCRIPTION The Battery Pack FM3K-BP is an autonomous Unit containing the following elements: - Batteries for the fire lines: TWO (FOUR optionally) 12V 1,2Ah batteries. Leadacid type, sealed with gel-immobilized electrolyte. - Battery for the System supply: ONE 12V 5,7Ah battery. Lead-acid type, sealed with gel-immobilized electrolyte. - Line power supply (230Va.c 50Hz or 117Va.c. 60Hz) for the re-charge system.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 5.3.1.1 TEST (UNIT CONNECTED TO MAINS) The mains cord must be connected to a line receptacle with the correct characteristics (check for the voltage), the "CHARGE" LED must be ON. A charging process must be NOT already running (the LED indicators of the three batteries must be OFF).
Sistema FIREMASTER III "Millennium" Manuale di istruzioni the charge level sufficient: this situation is indicated turning ON (steady) the corresponding green LED. When a battery fails to pass the test above, two cases are possible: - the battery is still efficient but requires charging - the battery is failed and must be DISCARDED During the successive charging process, the proper condition will be discriminated. 5.3.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni When the charging is done, a TEST cycle will be automatically executed to verify the good result of the process: the measured parameters must fall within the limits of the table. A battery passing the test BEFORE CHARGING but failing the test AFTER THE CHARGE, is probably FAULTY or near to be. Before discarding definitely these batteries, it is suggested to REPEAT AT LEAST TWICE THE CHARGING CYCLE. 5.3.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 1) Avoid exposing the battery to extreme temperatures (below 0°C or OVER 45°C) for long periods. 2) When the SYSTEM is NOT IN USE, provide to charge regularly the batteries: the lead-acid batteries have a much longer life if maintained ALWAYS FULLY CHARGED. It is suggested a charge cycle of 12 hours every 30 days. The internal microprocessor system will take care to maintain the optimum charge level in any condition.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni ,We recall here the RECYCLING RULES concerning the battery disposal: it must absolutely avoided to dispose the failed batteries with the common garbage, call instead a specialized collecting center enabled for the recycling of this polluting waste! 5.5 INTERNAL BATTERIES REPLACEMENT When it is necessary to access the internal batteries for a check or replacement, proceed as follows: 1) If not already done, SWITCH OFF the Unit (Remote or Base).
Sistema FIREMASTER III "Millennium" Manuale di istruzioni The charging voltage of the Sonnenschein dryfit batteries (limited current) is 13,9V/14,2V at 20°C: the internal charging circuits are set to this value. Batteries of different manufacturers, could require different charging values up to 14,9V. The dryfit Sonnenschein batteries are SOLID GEL IMMOBILIZED and can be used without restrictions IN ANY POSITION.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 5.6 BATTERIES INSTALLATION INSIDE THE FM3KBP BATTERY PACK 1) Securing screws for the front-panel and steel points 2) Battery Pack FM3K-BP with the panel closed 3) Battery Pack FM3K-BP with the top panel REMOVED. Take care of the connections between the panel components and the printed circuit! 4) Printed Circuit of the battery-charger and the microprocessor supervisor system. 5) Rubber containers for the batteries 6) SYSTEM BATTERY 12V 5.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 6. GENERAL SAFETY RULES AND WARNINGS The following rules and suggestions should be accurately followed in order to be compliant with most obvious safety rules, to avoid serious and permanent damage to the FIREMASTER system and to obtain always the best performance: 1) Avoid any water spillage or spray on the front-panel of the Remote Units RX24B (also on the TX2000 of course!). The Units are NOT COMPLETELY WATERPROOF.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 14) When possible try to raise the Unit as much as possible from the ground: the propagation of the radio signals increases considerably if the antenna is placed far from the ground. 15) Avoid to operate with large natural or artificial obstacles (houses, hills, wire mesh) between the TX2000 and the Remote Units. Always try to operate with all the field Units in "line of sight" with the TX2000 transmitter.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 28) Carefully insulate all the wire joints and avoid any electric leakage (wires or joints wet!) between the wires of different lines or between the wires and the ground or metal surfaces. 29) Imperatively never use the FIREMASTER SYSTEM other than for control and firing of PYROTECHNIC SHOWS.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 7.0 TECHNICAL SPECIFICATIONS 7.1 TX2000 BASE UNIT - TECHNICAL SPECIFICATIONS CODE TRANSMISSION SYSTEM: bi-directional RADIO link RECEIVER: single-conversion super heterodyne, quartz-controlled, FM RECEIVING SENSITIVITY: 0.15µV/m at 20db S/N RECEIVING FREQUENCY: 40.665MHz TRANSMITTER: 4-stage, FM, quartz-controlled. TRANSMISSION FREQUENCY: 40.685MHz ±12kHz TRANSMISSION POWER: in conformity with FCC Cfr. 47 part.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 7.3 FM3K-BP BATTERY PACK TECHNICAL SPECIFICATIONS SYSTEM BATTERY: sealed accumulator, lead-acid type with solid gel electrolyte - 12V 5.7Ah FIRING LINES BATTERIES: 2 sealed accumulators lead-acid type with solid gel electrolyte - 12V 1.2Ah (up to 4 devices can be installed for a total capacity of 48V - 1.
Sistema FIREMASTER III "Millennium" 8 Manuale di istruzioni CERTIFICATIONS The FIREMASTER III "Millennium" SYSTEM is provided with the mandatory CE marking and fulfills all the rules and product specifications as required by the Law. In particular the FIREMASTER System has been tested by a qualified TEST CENTER recognized at European level as "Certified Body" : the following certifications have been obtained: - ELECTROMAGNETIC COMPATIBILITY: EN 301 489-03 V1.3.1 (2001) Rif.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 8.1 WARRANTY PARENTE FIREWORKS s.r.l Via Oberdan, 105 45037 MELARA (RO) -ITALY Tel. ++39-(0)425-89035 Fax ++39-(0)425-89640 www.parente.it info@parente.it Manufacturer of the FIREMASTER III "Millennium" SYSTEM and its accessories, grants all Units free from manufacturing defects for a period of 12 months from the purchasing date.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni 8.2 WARNINGS - DECLARATION 8.2.1 DECLARATION Hereby PARENTE FIREWORKS s.r.l Via Oberdan, 105 45037 MELARA (RO) -ITALY declares that this "SYSTEM FIREMASTER III "Millennium" composed by the following sub-assemblies: BASE UNIT Model TX2000-A REMOTE UNIT Model RX-24B BATTERY PACK Model FM3K-BP Is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC 8.2.
Sistema FIREMASTER III "Millennium" Manuale di istruzioni -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.