MG5000 MG5050 SP5500 SP6000 SP7000 User Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your comments.
User Settings For security reasons, write only the user’s name and not his or her access code.
Master Quick Menus User Step Action Details 1 [ The [ ] key will flash. LED/key on = programmed user. [PARTITION MASTER CODE] may also be used. 2 [USER NUMBER] 3 [CODE] Enter 4- or 6-digit code. 4 [CONFIRM CODE] Re-enter 4- or 6-digit code. 5 [LEARN REMOTE] / [ENTER] Press a button on the designated remote or [ENTER] to skip. Goes to the next available user, or if partitioned, go to step 6. 6 [1] and/or [2] + [ENTER] Assign the user to one or both partitions and press [ENTER].
Communicator Step Action Details 1 [ The [ ] key will flash. [PARTITION MASTER CODE] may also be used. 2 [MEM] 3 [3] = Personal Phone #1 [4] = Personal Phone #2 [5] = Personal Phone #3 [6] = Personal Phone #4 [7] = Personal Phone #5 [8] = Pager # 4 [PHONE #] + [ENTER] Enter phone # (up to 32 digits) and press [ENTER]. Goes to next phone#, or go to step 5 if [8] = Pager # was selected. 5 [MESSAGE] + [ENTER] Step 5 for Pager # only. Enter pager message and press [ENTER].
Table of Contents User Settings ..................................................... 0 System Features.................................................. 12 Master Quick Menus.......................................... 1 Display Mode................................................... 12 Overview................................................................. 4 Basic Operations ............................................... 4 Alarm Display ..................................................
Overview Thank you for selecting a security system from Paradox Security Systems Ltd. This advanced technology security system provides you with reliable security protection and powerful features that anyone can use without memorizing complex and confusing codes. The system consists of the control panel, one or more keypad modules, various input devices (e.g. motion detectors, door contacts, etc.) and various output devices (e.g. bells, sirens, lights, etc.).
Figure 2: MG32LED (32-zone LED Keypad Module) Zone Display: The numbers [1] to [32] correspond to zones 1 to 32 respectively. Open or entry delay zones are illuminated, and flash in alarm. Partition 1 Status Partition 2 Status Arm (red), Sleep (yel), Stay (grn): On = Partition armed Off = Partition disarmed Flash = Exit Delay Fast Flash*= Exit Delay (final 10 sec.
Figure 4: MG32LCD (32-zone Wireless LCD Keypad Module) Indicator Lights Power light (yel) On = Power on Off = Power off StayD light (grn) On = StayD mode enabled Keys = Press once + [MASTER CODE] for Quick Menu programming = Press & hold for keypad settings = Press & hold for chime programming [TBL] = Trouble display [MEM] = Alarm memory display [BYP] = Bypass programming Partitioning Your system is equipped with a partitioning feature that can divide your alarm system into two distinct areas identified a
StayD Mode To Turn On/Off StayD Mode To turn on StayD mode: [STAY] + [CODE] + [STAY] StayD light on Press the [STAY] key followed by a valid code, then press the [STAY] key again within ten seconds. The StayD light will light up to confirm StayD activation, and the system will be in Stay mode. To turn off StayD mode: [OFF] + [CODE] + [OFF] Off light on Press the [OFF] key followed by a valid code, then press the [OFF] key again within ten seconds.
Access Codes Programming Access Codes Access codes are personal identification numbers that allow you to enter certain programming modes, arm or disarm your system as well as activate or deactivate PGMs. The system supports the following: • 1 System Master Code • 2 Master Codes • 29 User Access Codes For information on how each access code can arm or disarm the system refer to the System Checklist on page 16.
Arming & Disarming Take full advantage of your system by familiarizing yourself with all the arming methods. If your system is not partitioned (see Partitioning on page 6), everything is considered as belonging to Partition 1. If you cannot arm because a zone is open, the system will enter in Bypass Programming. Enter the two digit zone you wish to bypass and press [ENTER], or press [ENTER] to bypass all open zones. Regular Arming This method will arm all the zones in the selected partition.
One-Touch Arming One-Touch arming allows you to arm the system without using an access code. This feature must be enabled by your installer. If One-Touch Arming is programmed, you can increase the security level of your system (from Disarm without a code. See Figure 4 on page 10. Stay Arm Sleep Arm Full Arm) One-Touch Regular Arming Press and hold the [ARM] key to arm all zones in the partition. If partitioned, keys [1] & [2] will flash.
How do I temporarily disable the Auto-Arm Timer? 1 Press the [ ] key. 2 Enter [MASTER CODE]. 3 Press the [BYP] key. The [BYP] key will flash to indicate you are in the System Options menu. 4 Press key [1] to set partition 1, or press key [2] to set partition 2. 5 Press and hold [SLEEP] to temporarily disable the Auto-Arm Timer. No Movement Auto Arming The alarm system can be programmed to arm the system and/or send a report if no zone activity occurs for a pre-programmed amount of time.
System Features Display Mode (MG32LRF only) The MG32LRF has two display modes. By default, the keypad will show all events (e.g. zones in alarm, bypassed zones, etc.) live as they occur. Alternatively, the system can be programmed by your installer to only display zones that cause an alarm or entry delay. If you want to see the status of all zones, press the [ ] key. Zones that are open but have not triggered an alarm will only be displayed after pressing the [ ] key.
Programming Chime Zones A Chime-enabled zone will advise you every time it is opened by causing your keypad to beep. Each keypad must be chimed separately. How do I chime zones? MG32LED / MG32LRF (32-zone hardwired & wireless LED keypad modules only) 1 Press & hold the [ ] key. The Arm1, Arm2, Stay1, and Stay2 LEDs will flash. Select the numbers corresponding to the zones you want to Chime by entering the two-digit zone number. For example, to 2 chime zone 2 enter [0] then [2].
Power Save Mode (MG32LRF only) If there is power loss on the wireless keypad, the module’s display will shut off and go into power save mode after one minute. Press the [INFO] key to activate the display. Trouble Display Your alarm system continuously monitors several trouble conditions that can be reported directly to your monitoring station. When a trouble condition occurs, the [TBL] key will illuminate.
Advanced Features Quick Function Keys Upon request of your installer or monitoring station you may have to perform one of the following. To enter Menu Programming, press [ ] and then enter your [MASTER CODE]. In Menu programming, press: Test Report [MEM] + [2] If your system is monitored by a monitoring station, this feature will send a test report code to the monitoring station. Call PC [MEM] + [1] Will initiate a call to the monitoring station that is using the WinLoad software.
System Checklist Zone # and Description Partition 1 or 2 01:___________________________________ Byp Stay Sleep Force 24Hr Entry Delay ______ N N N N N N 02:___________________________________ ______ N N N N N N 03:___________________________________ ______ N N N N N N 04:___________________________________ ______ N N N N N N 05:___________________________________ ______ N N N N N N 06:___________________________________ ______ N N N N N N 07:__________
Zone Description Special Keys and Features Is this system partitioned? Yes N No N Partition 1 = _____________________________________ Partition 2 = _____________________________________ N [ARM] One-Touch Regular arming is activated N [STAY] One-Touch Stay arming is activated N [SLEEP] One-Touch Sleep arming is activated N [BYP] One-Touch Manual Bypass Programming is Panic Alarms activated [1] & [3] Police or __________N Silent N Audible N Off [4] & [6] Aux.