USE OF THE BATTERY CARTRIDGE AND CHARGING UNIT
The charging unit is run with a nominal voltage of 120 V (CT-2500/LCHR), or (230 V for
CT-2500/LECHR) and a frequency of 50-60 Hz. New batteries must be charged prior to use. To remove the
battery, actuate the battery lock and pull it out of the tool. To charge the battery, connect the power plug of
the charging unit with the power supply and slide the battery into the charging unit. The charging time is 40
minutes. The charging level of the battery cartridge can be checked by the right LED (multi-color) of the
charging unit.
Left LED (Red)
Right LED (Multi-color)
Red Charging unit ready to operate Battery defective
Red Flashing
Charging unit out of order.
New or unused batteries whose
nominal capacity is not sufficient.
Battery too hot or too cold.
Remove battery.
Safety components possibly defective.
Green Charging cycle starts
Green Flashing
Battery fully charged.
Charging unit switches automatically into a
maintaining mode. Battery can stay in charger
for indefinite time w/o being damaged.
If the nominal capacity of the battery is not achieved, e.g. at first charge, the battery is not necessarily
faulty. Full capacity can be achieved after (3) charging/discharging cycles.
When the speed of the tool decreases noticeably, the battery must be recharged.
ATTENTION:
Do Not recharge a partially discharged battery as a precaution.
Charge the battery at room temperature between 50°F and 104°F (10°C and 40°C).
Charging batteries at low temperatures, under 41°F (5°C) is not possible. Increase battery
temperature before starting the charging cycle.
Do Not expose the charging unit to rain or snow.
Do Not charge a battery in the vicinity of explosive materials and gases.
No other batteries (e.g. dry batteries or car batteries, etc.) are to be used in the tool or in the charging
unit.
Do Not use the cord to transport the charging unit, or to pull the plug out of a wall socket with force.
Do Not insert foreign objects into the ducts of the charging unit. Pull the plug of the charging unit after
charging. Do Not disassemble the charging unit or battery.
ATTENTION:
Do Not place the battery in your pocket or in your toolbox if there are any conductive
materials in it such as coins, keys, tools or other metallic parts.
TERMINATIONS PER BATTERY CHARGE
The estimated number of terminations before the battery will need to be recharged is dependent on variables
such as the connector size and type being terminated, ambient temperature, and time lapsed between
termination cycles as well as other variables.