Installation Manual LKM-A111-BC / LKM-A121-BC LKM-A111-BD / LKM-A121-BD S-AIT Tape Drive Unit S-AIT is an abbreviation of Super Advanced Intelligent Tape LMQT00623 Rev.
Table of Contents LKM-A111-BC / LKM-A111-BD IMPORTANT SAFETY NOTICE ................................................................ 2 WICHTIGE SICHERHEITSHINWEISE – German – ..................................... 4 Introduction ....................................................................................................... 6 About LKM-A111-B Tape Drive ..................................................................... 6 Product Features .............................................................
LKM-A121-BC / LKM-A121-BD IMPORTANT SAFETY NOTICE ............................................................... 14 WICHTIGE SICHERHEITSHINWEISE – German – .................................... 16 Introduction ...................................................................................................... 18 About LKM-A121-B Tape Drive .................................................................... 18 Product Features ...............................................................................
Operation ( for Model LKM-A111-BC / LKM-A111-BD / LKM-A121-BC / LKM-A121-BD ) .......... 27 LED Indication for Drive Status .................................................................... 27 Drive Operation .............................................................................................. 28 Interface Implementation ( for Model LKM-A111-BC / LKM-A111-BD / LKM-A121-BC / LKM-A121-BD ) .......... 29 Supported SCSI Messages .....................................................................
Installation Manual LKM-A111-BC / LKM-A111-BD
IMPORTANT SAFETY NOTICE NOTICE (1) You may not reproduce or transcribe any part of this publication without permission. (2) We reserve the right to revise this document at any time without notice. (3) If you have any questions about this document, contact your sales representative. SAFETY NOTICE (1) To prevent fire or electric shock, do not expose this appliance to rain or moisture. (2) To avoid electric shock, do not attempt to disassemble the cabinet.
IMPORTANT SAFETY INSTRUCTIONS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Read all of these instructions. Save these instructions for later use. Follow all warnings and instructions marked on the product. Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. Do not use this product near water. Do not place this product on an unstable rack, cart, stand, or table.
– German – WICHTIGE SICHERHEITSHINWEISE HINWEISE (1) Ohne Genehmigung dürfen keine Auszüge dieser Veröffentlichung reproduziert oder übertragen werden. (2) Wir behalten uns das Recht vor, dieses Dokument jederzeit ohne Vorankündigung zu überarbeiten. (3) Wenn Sie Fragen zu diesem Dokument haben, wenden Sie sich an Ihren Verkaufsrepräsentanten. SICHERHEITSHINWEISE (1) Setzen Sie dieses Gerät zur Vermeidung eines Brandes oder elektrischen Schlages weder Regen noch Feuchtigkeit aus.
– German – WICHTIGE SICHERHEITSANWEISUNGEN 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Lesen Sie sich alle hier aufgeführten Anweisungen durch. Bewahren Sie diese Anweisungen für eine spätere Verwendung auf. Befolgen Sie alle auf dem Produkt gekennzeichneten Warnungen und Anweisungen. Trennen Sie dieses Produkt vor der Reinigung von der Wandsteckdose ab. Verwenden Sie keine Flüssigreiniger oder Aerosolreiniger. Reinigen Sie das Gerät mit einem feuchten Tuch.
Introduction About LKM-A111-B Tape Drive The LKM-A111-B drive is a high capacity data storage device using Super Advanced Intelligent tape (S-AIT) technology. The LKM-A111-B drive achieves high data reliability through Read-After-Write, an additional level of Error Correction Code, and other features. The LKM-A111-B drive stores data on tape using a standard format called S-AIT (Super Advanced Intelligent Tape) and ALDC (Adaptive Lossless Data Compression) formats.
System Requirements • SCSI Interface Card (Recommended) ' SCSI Card 29160 ' series (by Adaptec) Note: This product is NOT supported with other SCSI Interface or PCMCIA card than the above Card.
Precautions Installation Avoid placing the drive in a location subject to: - high humidity - high temperature - mechanical shock and vibration - direct sunlight Operation • Do not move the drive while it is operating. It may cause malfunction. • Avoid exposing the drive to sudden changes from a low to high in temperature. This may cause water condensation to collect inside the drive. If the ambient temperature changes suddenly in transit, wait for more than four hours before turning on the drive.
Parts and Functions Front View ➁ ➀ ➈ ➆➇ Front Door Closing Front Door Opening ➂➃➄➅ ➉ 11 ➂➃➄ ➅ 12 ➀ Front-Door ➁ Front-Door Button Push the button to open the Front-Door ➂ Tape Motion LED *1 Indicates the cartridge-tape operating status ➃ Drive Error LED *1 Indicates the drive error status ➄ Tape Error LED *1 Indicates the cartridge-tape error status ➅ Cleaning Request LED Indicates the cleaning request status ➆ Power ON/OFF Switch ➇ Power LED Lights up "Green" when the Tape Drive Unit is ON
Rear View ➀ ➂ ➃ ➁ ➄ ➀ Connector for maintenance Not use generally ➁ Fan / Air Flow Hole ( for release ) Not be blocked or covered to protect this Library from overheating ➂ SCSI Interface Connector Connect the SCSI interface cable ( 68-pin half pitch type ) ➃ SCSI ID Switch Set up SCSI ID number (other number(0~15) than ones that have already used on your SCSI bus) Default ID number = " 0 " ➄ Power Connector Connect the power cord 10 LKM-A111-BC / LKM-A111-BD
Installation Option Switches ( DIP Switch ) The dip switches locate on the bottom of this drive. ( Not operate these switches generally.
Memo 12
Installation Manual LKM-A121-BC / LKM-A121-BD
IMPORTANT SAFETY NOTICE NOTICE (1) You may not reproduce or transcribe any part of this publication without permission. (2) We reserve the right to revise this document at any time without notice. (3) If you have any questions about this document, contact your sales representative. SAFETY NOTICE (1) To prevent fire or electric shock, do not expose this appliance to rain or moisture. (2) To avoid electric shock, do not attempt to disassemble the cabinet.
LASER SAFETY INFORMATION This drive unit is classified as a Class 1 Laser Product mounted the drive that is certified to conform to the requirements of the International Electrotechnical Commission (IEC) 60825-1 and CENELEC EN60825-1 for Class 1 laser products. CAUTION : (1) The use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
– German – WICHTIGE SICHERHEITSHINWEISE HINWEISE (1) Ohne Genehmigung dürfen keine Auszüge dieser Veröffentlichung reproduziert oder übertragen werden. (2) Wir behalten uns das Recht vor, dieses Dokument jederzeit ohne Vorankündigung zu überarbeiten. (3) Wenn Sie Fragen zu diesem Dokument haben, wenden Sie sich an Ihren Verkaufsrepräsentanten. SICHERHEITSHINWEISE (1) Setzen Sie dieses Gerät zur Vermeidung eines Brandes oder elektrischen Schlages weder Regen noch Feuchtigkeit aus.
– German – WICHTIGE SICHERHEITSANWEISUNGEN 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Lesen Sie sich alle hier aufgeführten Anweisungen durch. Bewahren Sie diese Anweisungen für eine spätere Verwendung auf. Befolgen Sie alle auf dem Produkt gekennzeichneten Warnungen und Anweisungen. Trennen Sie dieses Produkt vor der Reinigung von der Wandsteckdose ab. Verwenden Sie keine Flüssigreiniger oder Aerosolreiniger. Reinigen Sie das Gerät mit einem feuchten Tuch.
Introduction About LKM-A121-B Tape Drive The LKM-A121-B drive is a high capacity data storage device using Super Advanced Intelligent tape (S-AIT) technology. The LKM-A121-B drive achieves high data reliability through Read-After-Write, an additional level of Error Correction Code, and other features. The LKM-A121-B drive stores data on tape using a standard format called S-AIT (Super Advanced Intelligent Tape) and ALDC (Adaptive Lossless Data Compression) formats.
Introduction Product Features LKM-A121-B Data Capacity 500 GByte uncompressed (with SAIT-1 600 m tape) 1300 GByte compressed * (with SAIT-1 600 m tape) Transfer Rate 30 MByte/s uncompressed (sustained) 78 MByte/s compressed * * This is assuming 2.6 : 1 compression ratio.
System Requirements • FC Cable Requirements Transfer rate : 1 Gbit/s or 2 Gbit/s , Connector type : LC Transfer media : Optical-Multi mode, Short wave-length laser Cable length (Maximum) : 500 m (1 Gbit/s), 300 m (2 Gbit/s) Connecting Cable (Recommended) : ' FCLLM-xxx ' series (by Cybernetech) Note : FC = Fiber Channel • FC Interface HBA Board (Recommended) ' LSI40919 ' series (by LSI Logic) • Cartridge-tape (Recommended) LKM-SA1-500 ( Panasonic ) • Cleaning Tape (Recommended) LKM-SA1-CL ( Panasonic ) • Bac
Precautions Installation Avoid placing the drive in a location subject to: - high humidity - high temperature - mechanical shock and vibration - direct sunlight Operation • Do not move the drive while it is operating. It may cause malfunction. • Avoid exposing the drive to sudden changes from a low to high in temperature. This may cause water condensation to collect inside the drive. If the ambient temperature changes suddenly in transit, wait for more than four hours before turning on the drive.
Parts and Functions Front View ➁ ➀ ➈ ➆➇ Front Door Closing ➂➃➄➅ Front Door Opening ➉ 11 ➂➃➄ ➅ 12 ➀ Front-Door ➁ Front-Door Button Push the button to open the Front-Door ➂ Tape Motion LED *1 Indicates the cartridge-tape operating status ➃ Drive Error LED *1 Indicates the drive error status ➄ Tape Error LED *1 Indicates the cartridge-tape error status ➅ Cleaning Request LED Indicates the cleaning request status ➆ Power ON/OFF Switch ➇ Power LED Lights up "Green" when the Tape Drive Unit is ON
Rear View ➀ ➂➃ ➁ ➄ ➀ Connector for maintenance Not use generally ➁ Fan / Air Flow Hole ( for release ) Not be blocked or covered to protect this Library from overheating ➂ Fibre Channel Connector Connect the Fibre Channel interface cable. Note: In advance, put the SFP Fibre Channel Module (attached) into the drive unit. ➃ Jumper Sets LOOP ID, parity-check, etc. For details of each jumper setting, refer to 'FC Connection/Setting the LOOP ID' in next page.
Installation FC Connection/Setting the LOOP ID LOOP ID 6 5 4 3 2 1 0 LOOP ID 0 1 2 3 FC Connector Power Connector 4 Jumpers 5 122 123 LOOP ID 124 Enable 125 Disable LOOP ID 0 LOOP ID 1 LOOP ID 2 LOOP ID 3 LOOP ID 4 LOOP ID 5 LOOP ID 6 ... ... 121 LOOP ID Enable 6 Reserved Note : Reserved = CLOSED/Jumper = OPEN/Jumper not installed Loop ID Jumper This jumper is functional when the topology is arbitrated loop.
Arbitrated Loop Physical Addresses (AL_PA) and Loop IDs (Decimal) 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 EF E8 E4 E2 E1 E0 DC DA D9 D6 D5 D4 D3 D2 D1 CE CD CC CB CA C9 C7 C6 C5 C3 BC BA B9 B6 B5 B4 B3 B2 B1 AE AD AC AB AA A9 A7 A6 A5 lowest priority (Decimal) 8-bit AL_PA (Hex) (Hex) (Decimal)
Option Switches ( DIP Switch ) The dip switches locate on the bottom of this drive. ( Not operate these switches generally.
Operation ( for Model LKM-A111-BC / LKM-A111-BD / LKM-A121-BC / LKM-A121-BD ) LED Indication for Drive Status The LED indicators are defined as follows LED TAPE MOTION GREEN, ALL lit (0.5 sec.) then YELLOW blinks from left LED to right LED repeatedly. (during Diag for 2 to 3 sec.
Drive Operation About the Cartridge Tapes To avoid condensation onto the cartridge, the Library and cartridge must be kept away from quick fluctuation (15 deg/ hr) in temperature. If the ambient temperature changes suddenly, leave around 12 hours in suitable environment before you use it again. Life extension period of cartridge tape depends on environmental condition, usage and cleaning cartridge tape.
Interface Implementation ( for Model LKM-A111-BC / LKM-A111-BD / LKM-A121-BC / LKM-A121-BD ) Supported SCSI Messages Abort Bus Device Reset Command Complete Disconnect Extended Message - Synchronous Data Transfer Request - Wide Data Transfer Request Identify ( w/&w/o Disconnect ) Ignore Wide Residue Message Parity Error Message Reject No Operation Restore Pointers Save Data Pointer Supported SCSI Commands Erase Inquiry Load/Unload Locate Log Sense Log Select Mode Select Mode Sense Prevent Allow Medium Re
Maintenance ( for Model LKM-A111-BC / LKM-A111-BD / LKM-A121-BC / LKM-A121-BD ) We recommend to maintain periodically the drive and the cartridge-tape to use safely and comfortably. When maintaining, please take care the below contents. ■ Keep the cartridge-tape away from direct sunlight, high temperature, and high humidity place. If it is not, it may result in the data destroy. ■ Do not touch on the tape surface. If touch it, it may result in the data destroy.
Filter Exchanging The Filter is attached on the Air Flow Hole in bottom of the drive unit. We recommend to exchange the Filter about one time in a year as following steps. Tub Filter Removing 1) Push the tub in left end of the Filter attached to the Air Flow Hole to unlock. 2) Slide the Filter to left(arrow) direction to unlock the Center Lock. 3) Remove the Filter from the drive unit. When the Center Lock is unlocked, the Right End Lock is unlocked at the same time, and then the all Filter is removed.
Specification ( for Model LKM-A111-BC / LKM-A111-BD / LKM-A121-BC / LKM-A121-BD ) Cartridge Tape Performance Data Capacity (S-AIT1 / 600 m) *1 500 GByte ( compression mode : 1300 GByte ) Transfer Rate (S-AIT1) *2 30 MByte/s ( compression mode : 78 GByte/s ) Note : *1 ) Compression Rate = 2.6 x ( Compression Rate is changed with data type.) *2 ) Transfer Rate may be different with system(host PC) performance.
Appendix ( for Model LKM-A111-BC / LKM-A111-BD / LKM-A121-BC / LKM-A121-BD ) Mounting the Drive Unit to Rack 1) If you need the Rail (Rail-Bracket) or Angle for mounting to your rack, attach the suitable ones for the Rack / Drive unit to them. – For details of installing the Rail (Rail-Bracket) or Angle, refer to each manual for them. 2) Gently slide the Drive unit into the vacant rack part, and secure it with the mounting screws as below figure.
– German – Anhang ( für den Typ LKM-A111-BC / LKM-A111-BD / LKM-A121-BC / LKM-A121-BD ) Montage 1) Wenn Sie für die Montage in Ihr Rack die Schiene (Schienenträger) oder den Winkel benötigen, befestigen Sie bitte das für das Rack / die Antriebseinheit passende Teil. – Einzelheiten zur Installation der Schiene oder des Winkels finden Sie im entsprechenden Handbuch.
Memo 35
Specifications are subject to change without notice. LMQT00623 Printed in Japan Rev.