CAUTION Read all instructions carefully prior to installation. The Power Monitoring Module should only be connected to the type of power source indicated on the label. Adhere to voltage and amperage guidelines and utilize a proper branch circuit protector. No field-serviceable parts. Do not attempt to disassemble the product as potentially severe electrical shock may result. Installation and maintenance must be performed by qualified personnel.
Regulatory Information [this will need to be updated following certification] This product has been tested to the following requirements: UL / ANSI standards 61010-1,Second Edition, Dated July 12, 2004 with revisions through and including October 28, 2008 CAN/CSA-C22.2 No. 61010-1, second edition, including Amendment 1, or a later version of the same standard incorporating the same level of testing requirements.
Packet Power™ Monitoring Module Users Manual Safety summary and specifications This general safety information is to be used by both the Power Monitoring Module (PMM) operator and servicing personnel. Packet Power LLC assumes no liability for user’s failure to comply with these safety guidelines. Please read this manual carefully before proceeding. This symbol is used throughout this manual to indicate critical safety information.
Packet Power™ Monitoring Module Users Manual Contents Safety summary and specifications ........................................................................................ i Contents................................................................................................................................ ii Introduction .......................................................................................................................... 1 Using this Manual ....................................
Packet Power™ Monitoring Module Users Manual Installing the current transformer connections .............................................................22 Installing the voltage circuit connections ......................................................................22 Verifying PMM connections .........................................................................................22 Mounting the PMM ......................................................................................................
Packet Power™ Monitoring Module Users Manual Introduction Using this Manual This manual contains information about the Packet Power™ Power Monitoring Module (“PMM”) and associated software. This manual is divided into two parts. The first part is relevant to products using the P5T3 models of the PMM. The second part is relevant to the P2T3 models of the PMM. The PMM model number and associated information is noted on the product label.
Packet Power™ Monitoring Module Users Manual P5T3 Models The P5T3 provides the following enhancements over the original models: Capable of supporting 60 to 270 volts Support for 2.4GHz and 860-920MHz radio spectrum Local LED display Compatibility with a broader range of current transformers Installation Safety prerequisites The PMM should be installed only by qualified technicians with a solid understanding of electrical wiring and devices.
Packet Power™ Monitoring Module Users Manual L-L L-L 3Ø Delta 208V 3Ø Delta 380+V P5T3 X Y Z CTX Not supported CTY Figure LINE X Y Z N G IA+ IAIB+ IBIC+ ICN VA VB VC CTX PMM X LOAD 100 – 240 V N Figure 1. 1Ø L-N Wiring, L1 LINE X Y Z N G IA+ IAIB+ IBIC+ ICN VA VB VC CTX LOAD PMM X 100 – 240 V N Figure 2. 1Ø L-N Wiring diagram with ground, L1 Copyright 2009-2013 Packet Power, LLC.
Packet Power™ Monitoring Module Users Manual LINE X Y Z N G IA+ IAIB+ IBIC+ ICN VA VB VC CTY PMM Y LOAD 100 – 240 V N Figure 3. 1Ø L-N Wiring diagram, L2 LINE X Y Z N G IA+ IAIB+ IBIC+ ICN VA VB VC CTZ LOAD PMM Z 120V N Figure 4. 1Ø L-N Wiring diagram, L3 Copyright 2009-2013 Packet Power, LLC.
Packet Power™ Monitoring Module Users Manual LINE X Y Z N G IA+ IAIB+ IBIC+ ICN VA VB VC CTX CTY CTZ PMM X LOAD 120V 208V N 120V Z Y Figure 5. 1Ø 208V L-L wiring diagram, L1-L2 load LINE X Y Z N G IA+ IAIB+ IBIC+ ICN VA VB VC CTY PMM X LOAD 120V Z N 208V 120V Y Figure 6. 1Ø 208V L-L wiring diagram, L2-L3 load Copyright 2009-2013 Packet Power, LLC.
Packet Power™ Monitoring Module Users Manual LINE X Y Z N G IA+ IAIB+ IBIC+ ICN VA VB VC CTZ PMM X LOAD 120V 208V N 120V Z Y Figure 7. 1Ø 208V L-L wiring diagram, L1-L3 load LINE X Y Z N G IA+ IAIB+ IBIC+ ICN VA VB VC CTX CTY CTZ PMM X LOAD 208V 208V N 120V Z 208V Y Figure 8. 3Ø Wye 120/208V L-N wiring diagram Copyright 2009-2013 Packet Power, LLC.
Packet Power™ Monitoring Module Users Manual LINE X Y Z N G IA+ IAIB+ IBIC+ ICN VA VB VC CTX CTY CTZ PMM X LOAD <250V <250V N Z <250V Y Figure 9. 3Ø Wye 240/415V L-N wiring diagram LINE X Y Z G IA+ IAIB+ IBIC+ ICN VA VB VC CTX CTY PMM X LOAD <250V <250V Z Y <250V Figure 10. 3Ø Delta L-L wiring diagram Choosing the correct current transformers The PMM can operate with a variety of standard current transformers (C/Ts).
Packet Power™ Monitoring Module Users Manual 1. The C/T must be approved by Packet Power for use with the PMM. 2. The C/T must be sized correctly for the maximum current of the circuit being measured. 3. The C/T must meet all local and national safety requirements relevant to the installation, including but not limited to maximum voltage and any other relevant mechanical requirements. 4. The output of the C/T must be compatible with the PMM.
Packet Power™ Monitoring Module Users Manual 1. You are using the correct voltage version of the PMM for your configuration. 2. All current transformers have been correctly located over the load-carrying lines (please consult C/T documentation if necessary) 3. All current transformers have been correctly and securely connected to the PMM terminals 4. All voltage connections have been correctly and securely connected to the PMM terminals.
Packet Power™ Monitoring Module Users Manual 3 Note: If the current transformer(s) are located in the same enclosure as the PMM, you must ensure that any electrical code fill rate requirements are being met. LED readings and indicator lights The PMM has 3 large alpha-numeric LEDs that provide for local display of monitoring data and 3 small lights adjacent to the LEDs that provide operating status information. The PMM can be configured to display all or some of the following data via the numeric LEDs.
Packet Power™ Monitoring Module Users Manual 2.4 GHz radio activity o off: disabled o solid on: active, not connected o slow flashing: active, connected to the mesh network o rapid flashing: connected in near communication mode o very rapid flashing: test/configuration mode Lower small light (green) Power monitoring activity o off: power monitor disabled or not functional o slow flashing: active, monitoring power o very rapid flashing: test/configuration mode Copyright 2009-2013 Packet Power, LLC.
Packet Power™ Monitoring Module Users Manual Maintenance and Repair Maintenance The PMM has no user-serviceable parts and requires no maintenance. If necessary, clean the outside of the PMM using a clean, dry cloth. Repair The PMM contains no field-serviceable components. Failed products should be returned to Packet Power for replacement. For any service or repair information please contact Packet Power at support@packetpower.com. Please be sure to enclose the 16-character serial number.
Packet Power™ Monitoring Module Users Manual Mechanical Enclosure Enclosure material Weight (w/out CTs) Dimensions (core) Dimensions (including mounting tabs and connectors) All versions High-impact resistant Lexan, V0 flammability rating 3.6 oz / 105 g 2.8 in x 1.6 in x 1.4 in 71 mm x 40 mm x 36 mm 4.2 in x 1.6 in x 1.8 in 106 mm x 40 mm x 45 mm Environmental Operating conditions Operating temperature Humidity Max.
Packet Power™ Monitoring Module Users Manual Product Safety Label The product safety label can be found on the side of the PMM. Copyright 2009-2013 Packet Power, LLC.
Packet Power™ Monitoring Module Users Manual P2T3P 125V and 250V Models Installation Safety prerequisites The PMM should be installed only by qualified technicians with a solid understanding of electrical wiring and devices. Familiarity with and understanding of all terms used in this section is assumed. The user is responsible for ensuring that all electrical connections are safely performed in accordance with all applicable codes and regulations using appropriate tools and materials.
Packet Power™ Monitoring Module Users Manual 3P4W 3P5WG 3P3W 3P4WG 2P2W 2P2WG 3P4W 3P5WG 3P3W 3P4WG 3Ø Wye 120V/208V 3Ø Wye 120V/208V 3Ø Delta 208V 3Ø Delta 208V 1Ø 220V 1Ø 220V 3Ø Wye 220V/380V 3Ø Wye 220V/380V 3Ø Delta 380V 3Ø Delta 380V PMM 120V PMM 120V PMM 240V PMM 240V PMM 240V PMM 240V PMM 240V PMM 240V X X X X X X X X Y Y Y Y Y Z Z N CTX N CTX Z CTX Z CTX N CTX N CTX N CTX Z N CTX Not supported Not supported CTY CTY CTY CTY CTZ CTZ CTY CTZ Figure Figure Figure Figure Figure Figure Figur
Packet Power™ Monitoring Module Users Manual LINE X Y Z N G IA+ IAIB+ PMM IBIC+ IC- 120V N Version VA VB VC CTX X LOAD 120V N Figure 9. 1Ø 120V Wiring diagram, X-N load (2P3WG) LINE X Y Z N G IA+ IAIB+ PMM IBIC+ IC- 120V N Version VA VB VC CTY LOAD Y 120V N Figure 10. 1Ø 120V Wiring diagram, Y-N load (2P3WG) Copyright 2009-2013 Packet Power, LLC.
Packet Power™ Monitoring Module Users Manual LINE X Y Z N G IA+ IAIB+ PMM IBIC+ IC- 120V N Version VA VB VC CTZ Z LOAD 120V N Figure 11. 1Ø 120V Wiring diagram, Z-N load (2P3WG) LINE X Y Z N G IA+ IAIB+ PMM IBIC+ IC- 240V N Version VA VB VC CTX CTY CTZ X LOAD 120V 208V N 120V Z Y Figure 12. 1Ø 208V wiring diagram (2P3WG), X-Y load Copyright 2009-2013 Packet Power, LLC.
Packet Power™ Monitoring Module Users Manual LINE X Y Z N G IA+ IAIB+ PMM IBIC+ IC- 240V N Version VA VB VC CTY X LOAD 120V Z N 208V 120V Y Figure 13. 1Ø 208V wiring diagram (2P3WG), Y-Z load LINE X Y Z N G IA+ IAIB+ PMM IBIC+ IC- 240V N Version VA VB VC CTZ X LOAD 120V 208V N Z 120V Y Figure 14. 1Ø 208V wiring diagram (2P3WG), Z-X load Copyright 2009-2013 Packet Power, LLC.
Packet Power™ Monitoring Module Users Manual LINE X Y Z N G IA+ IAIB+ PMM IBIC+ IC- 120V N Version VA VB VC CTX CTY CTZ X LOAD 208V 120V 208V N 120V Z 120V 208V Y Figure 8. 3Ø Wye 120V/208V wiring diagram (3P4W, 3P5WG) LINE X Y Z G IA+ IAIB+ PMM IBIC+ IC- 240V N Version VA VB VC CTX CTY X LOAD 208V 208V Z Y 208V Figure 9. 3Ø Delta 208V wiring diagram (3P3W, 3P4WG) Copyright 2009-2013 Packet Power, LLC.
Packet Power™ Monitoring Module Users Manual LINE X Y Z N G IA+ IAIB+ PMM IBIC+ IC- 240V N Version VA VB VC CTX X LOAD 220V N Figure 10. 1Ø 230V wiring diagram (2P2W, 2P3WG) Note: X-N load shown. See Figures 2 & 3 for guidance on how to wire Y-N and Z-N loads. LINE X Y Z N G IA+ IAIB+ PMM IBIC+ IC- 240V N Version VA VB VC CTX CTY CTZ X LOAD 380V 220V 380V N 220V 220V Z Y 380V Figure 11.
Packet Power™ Monitoring Module Users Manual 1. The C/T must be approved by Packet Power for use with the PMM. 2. The C/T must be sized correctly for the maximum current of the circuit being measured. 3. The C/T must meet all local and national safety requirements relevant to the installation, including but not limited to maximum voltage and any other relevant mechanical requirements. 4. The output of the C/T must be compatible with the PMM. Each C/T input is fuseprotected with a 250mA safety fuse.
Packet Power™ Monitoring Module Users Manual 6. All current transformers have been correctly located over the load-carrying lines (please consult C/T documentation if necessary) 7. All current transformers have been correctly and securely connected to the PMM terminals 8. All voltage connections have been correctly and securely connected to the PMM terminals.
Packet Power™ Monitoring Module Users Manual 3 Note: If the current transformer(s) are located in the same enclosure as the PMM, you must ensure that any electrical code fill rate requirements are being met. Maintenance and Repair Maintenance The PMM has no user-serviceable parts and requires no maintenance. If necessary, clean the outside of the PMM using a clean, dry cloth. Repair The PMM contains no field-serviceable components in the PMM.
Packet Power™ Monitoring Module Users Manual Technical Specifications Electrical Service types 1Ø 120V 3Ø Wye 120V/208V 120V Version 2P2W, 2P3WG 3P4W, 3P5WG Service types 1Ø 208V 1Ø 230V 3Ø Wye 230V/400V 3Ø Delta 220V 240V Version 2P3WG 2P2W, 2P2WG 3P4W, 3P5WG 3P3W, 3P4WG Voltage inputs Voltage rating Current rating Frequency range Category 120V version 100-120V 10mA (max.
Packet Power™ Monitoring Module Users Manual Environmental Operating conditions Operating temperature Humidity Max. operating altitude Pollution degree All versions -7 to +45 C (+20 to +113F) 5% to 95% non-condensing 2000m (6561ft) 2 Communication Information gathered by the PMM is transmitted via a Packet Power radio network operating in a subset of the range between 860 and 930MHz (the exact frequencies vary with region – please contact Packet Power for details).
Packet Power™ Monitoring Module Users Manual Copyright 2009-2013 Packet Power, LLC.