J801X Technical Specs

Ultra-low emissions: 65% less NOx than standard
furnaces.
100% fired and tested: All units and each component
are tested on the manufacturing line.
Low Boy Height: Easy to apply in low ceiling applications,
works well with taller high SEER coils, easier to handle
and install.
Tubular primary heat exchanger: Heavy gauge
aluminized steel heat exchanger assures a long life.
30 second blower delay at start-up: Assures a warm
duct temperature at furnace start-up. Adjustable blower
off settings (60, 90, 120 and 180 seconds).
30 second post purge: Increases life of heat exchanger.
Hot surface igniter: Innovative application of a silicon
nitride igniter.
Color coded wire harness: Designed to fit the
components, all with quick-connect fittings for ease of
service and replacement.
High static blowers: All models equipped with high static
blowers.
60 second cooling cycle blower-off delay (TDR):
increases cooling performance.
Flexible category I venting system: May be vented with
dedicated venting system or common vented with other
category one appliances.
High efficiency blower kits: Maximize efficiencies and
provide better temperature control, humidity control and
air distribution.
Multi-speed direct drive blower: Energy-efficient,
brushless DC (ECM). Designed to give a wide range of
cooling capacities. Switches on PCB, provide ultra easy
motor speed selection.
Diagnostic lights for easy troubleshooting without
counting flashes: Dedicated light for flame signal strength
and 2 lights in combination to indicate all other fault codes
with easy to recognize states without counting flashes.
Integrated control board: Incorporates connections
for electronic air cleaner and humidifier. Ergonomically
located for ease of service.
Two piece door design: Enhances furnace appearance
and uses captured screws to prevent loosing door screws.
Furnace Air Leakage: These furnaces comply with
Energy Star cabinet air leakage requirement of less than
or equal to 2%. Keep the conditioned air flowing to where
it's needed.
Induced Draft - 80+ AFUE, Ultra-Low NOx
Input 55,000 - 100,000 Btuh
J801X(*)L Series
Single Stage Upflow/Horizontal
Gas Furnaces
The gas furnace may be installed free standing in a utility
room, basement, or enclosed in an alcove or closet. The
rounded corner jacket provides a pleasing “appliance
appearance. Design certified by CSA for application in
the United States.
FEATURES and BENEFITS
TECHNICAL
SPECIFICATIONS
This furnace series is approved and certified by the
SCAQMD and the SJVAPC Districts in the state of
California with NOx levels below 14 ng/J when operating
on natural gas.