Hub-10 Additional Info

Overview Guide
Contact Technical Support:
Telephone: +1.360.618.4363
Email: Support@outbackpower.com
Website: www.outbackpower.com
IMPORTANT:
Not intended for use with
life support equipment.
OutBack Power and the OutBack Power logo are trademarks owned and used by
OutBack Power Technologies, Inc. The ALPHA logo and the phrase “member of
the Alpha Group” are trademarks owned and used by Alpha Technologies.
These trademarks may be registered in the United States and other countries.
1.27"
(3.2 cm)
4.23"
(10.7 cm)
6.18"
(15.7 cm)
Figure 1 Dimensions
Figure 2 Mounting
#10 x ½” Screws x 2 Cable, CAT5e, 3' (1 m) x 2
Parts List
Cable, CAT5e, 10' (3 m) x 4
Shutter Bushing x 2
Snap Bushing x 2
Cable, CAT5e, 6' (2 m) x 3
Stacking (Series)
Figure 10 Series Stack (OutBack)
 Up to 10 inverters or other devices; requires balancing transformer
 Master inverter and half of the Slave inverters use common output AC bus (L1)
 The remaining Slave inverters use a separate common AC bus (L2)
 Master inverter is always active; regulates output based on load;
can power both L1 and L2 buses using balancing transformer
 Slave inverters remain in Power Save mode; Master activates
any Slave inverters for either L1 or L2 based on load
 Unused ports can host other devices (not shown here)
Figure 9 Series Stack (Classic)
 2 inverters; up to 8 other devices
 Master and single Slave inverter use separate output AC buses (L1 and L2)
 Both inverters always active (no Power Save mode); outputs are loaded
independently but output regulation is controlled by load on Master
 Ports 3 through 10 can host other devices
(3 and 4 shown here)
FX / VFX (includes
J, M, N Series)
GTFX
GVFX
GTFX (LA Series)
GVFX (LA Series)
Models
GFX
Ports 2 to 10 can be assigned to either
OB Slave L1 or OB Slave L2;
equal numbers of inverters should be
assigned to each side
Inverter Stacking
Port 1
Stack Mode Master or 1-2phase Master
Inverter Stacking
Port 2
Stack Mode OB Slave L1
or
OB Slave L2
FX / VFX (includes
J, M, N Series)
Models
Inverter Stacking
Port 1
Stack Mode Master
or
1-2phase Master
Master (port 1 only)
Slave (port 2)
Jumper
position
(see
Figure 3)
10 9 8 7 6 5 4 3 2 1
X
1
st
MATE
Master
(L1)
Jumper
position
(see
Figure 3)
Slave
(L2)
Inverter Stacking
Port 2
Stack Mode Classic Slave
or
or
Master (port 1 only)
Slave (port 2)
Single-phase
inverters:
Split-phase output
Output
Single-phase
inverters:
Split-phase output
Output
10 9 8 7 6 5 4 3 2 1
X
1
st
MATE
Slave
(L2)
Slave
(L2)
Slave
(L2)
Slave
(L2)
Slave
(L2)
Slave
(L1)
Slave
(L1)
Slave
(L1)
Slave
(L1)
Master (L1)
900-0154-01-00 REV E
©2013 OutBack Power Technologies. All Rights Reserved.
NOTE: See inverter literature for more
information on stacking modes and designations.
HUB10.3
Communications
Manager
HUB10.3 HUB Wiring Cover
3.
1" recommended
2.
1.
or
or
Date and Revision
July 2016, Revision E

Summary of content (4 pages)