OTIS ONE DATA SOLUTION NAA Dwg : GAA25QZ_FIM_NAA Date : 2019-09-19 Page : 1/13 Installation steps Otis One Data Solution Authorization Date: Door Sensor: GAA817A6 CSA Gateway (GW): GAA512J1/J3 GAA512K1/K5 4G / CSA 2G / CSA Metal sheet GAA21305AES1 Document Revision: Date Author 2019-09-13 2019-09-19 M. TOUTAOUI M.
OTIS ONE DATA SOLUTION NAA Dwg : GAA25QZ_FIM_NAA Date : 2019-09-19 Page : 2/13 Installation steps CONTENTS 1 OPERATION DESCRIPTION/THEORY OF OPERATION ...................................................................................... 3 2 COMPONENTS FOR THE INSTALLATION .............................................................................................................. 4 2.1 2.2 2.3 3 DOOR SENSOR ..........................................................................................
OTIS ONE DATA SOLUTION NAA Dwg : GAA25QZ_FIM_NAA Date : 2019-09-19 Page : 3/13 Installation steps 1 Operation Description/Theory of Operation The Otis One data solution consists of a gateway (GW) and a door sensor: The door sensor communicates in "beacon (not connected) mode" with the gateway via BLE (Bluetooth Low Energy). The GW transmits data received OTIS One data solution sensors from as well as data received from OTIS controls system via RS422 interface to a cell network: e.g.
OTIS ONE DATA SOLUTION NAA Installation steps 2 Components for the installation 2.1 Door Sensor 2.
OTIS ONE DATA SOLUTION NAA 2.
OTIS ONE DATA SOLUTION NAA Installation steps 3 Gateway installation 3.1 General notes 3.1.1 Mounting close to the sensor 3.1.
OTIS ONE DATA SOLUTION NAA Dwg : GAA25QZ_FIM_NAA Date : 2019-09-19 Page : 7/13 Installation steps 3.1.3 LEDs and Battery status LED Status Description RED No No Power BLUE OK Bluetooth Door sensor connection GREEN OK Controller (SVT) connection WHITE OK Cloud connection (incl. cell connection) All OK LED light blinks every sec + no red light Note: In case of LED red illumination the battery has to be loaded.
OTIS ONE DATA SOLUTION NAA 3.
OTIS ONE DATA SOLUTION NAA 3.
OTIS ONE DATA SOLUTION NAA Installation steps 4 Sensor installation on car door Otis Elevator Company Proprietary Information © 2019, Otis Elevator Company Dwg : GAA25QZ_FIM_NAA Date : 2019-09-19 Page : 10/13
OTIS ONE DATA SOLUTION NAA Installation steps 5 Battery installation Otis Elevator Company Proprietary Information © 2019, Otis Elevator Company Dwg : GAA25QZ_FIM_NAA Date : 2019-09-19 Page : 11/13
OTIS ONE DATA SOLUTION NAA Installation steps Battery installation (continued) Otis Elevator Company Proprietary Information © 2019, Otis Elevator Company Dwg : GAA25QZ_FIM_NAA Date : 2019-09-19 Page : 12/13
OTIS ONE DATA SOLUTION NAA 5.1 Dwg : GAA25QZ_FIM_NAA Date : 2019-09-19 Page : 13/13 Installation steps Battery Data Sheet Description Mercury Free Alkaline Manganese Battery, AAA Size Chemical System Alkaline Manganese Nominal Voltage 1.5 Volts Nominal Dimensions Ø10.5 mm x 44.5 mm Terminals Protruded positive (+) and flat negative (-) contacts Warranty Period 36 months Average Weight 11.