5J0xxx / DM-070xxxx OPI-4012 Wireless 1D/2D Imager Instruction Manual (Tentative) OPTOELECTRONICS Co., Ltd.
Overview Thank you for purchasing the OPI-4012 wireless imager scanner. Please read this instruction manual carefully before handling this product. This instruction manual provides safety and operating instructions for the OPI-4012. Specifications and additional detailed settings are available in the OPI-4012 Master Specifications and the Universal Menu Book.
Table of Contents 1. Precautions for Your Safety......................................................................................................... 3 2. Handling Precautions ................................................................................................................... 6 3. Package Contents ........................................................................................................................ 8 4. Detailed View......................................................
1. Precautions for Your Safety For your own safety, read these procedures carefully before using this product. After reading this document, keep it accessible for future reference. This instruction manual includes the following symbols and markings to help you use this product properly and safely. The meanings of those symbols are described below. Be sure to remember their meanings.
■About the Scanner DANGER Do not use this device near flammable substances (such as gas and explosives). Prohibited WARNING Do not throw this device into a fire. Doing so may cause the battery case to burst, Prohibited resulting in injury or possibly acting as an accelerant for the fire. Do not insert foreign substances into the device. Doing so may short-circuit or overheat Prohibited the battery, resulting in fire or electric shock. Do not use this device while walking or driving.
CAUTION Do not drop this device or set it on an unstable surface from which it could fall. Prohibited Do not open the battery case lid in the area where battery is likely to contact with water. Prohibited Do not expose the battery pack to liquids or allow the battery contacts to get wet. ■About the Rechargeable Battery WARNING Do not attempt to modify or alter the battery. Doing so may cause the battery pack to Prohibited generate heat, or lead to burst, leakage, explosion or ignite.
2. Handling Precautions 2.1 Please follow the following instructions for proper usage. ・Do not leave this device in highly humid or dusty areas. ・When condensation occurs, such as when moving this device from a cold to a warm environment, dry the scanner before using it. ・Do not leave this device in areas where static electricity is easily generated (such as the carpeted area) or near equipment which generate magnetism (such as a TV or a radio). ・This device is a precision apparatus.
2.4 Frequency Band This device uses the 2.4 gHz frequency band. Read the following information carefully before using this device. In the frequency band of this scanner, scientific, medical and industrial devices, including microwaves, are used.
3. Package Contents The package contents are listed as below. Please confirm that you have the following items before getting started. - 1 scanner (OPI-4012) with an embedded battery pack 1 hand strap 1 copy of Instruction manual 1 dedicated AC adapter 9 The number of accessories may differ depending on the product specification. 9 Please contact the nearest dealer if accessories are damaged or missing.
4. Detailed View 4.1 OPI-4012 (Scanner) Part 1. Serial Label 2. Certification Label 3. Trigger Switch 4. Optical Window 5. Battery Cover 6. Hand Strap Hook 7. Buzzer Hole 8. Status LED 9. DC Jack Cover 10. Electrical Terminal (+) 11. Electrical Terminal (-) Function A certification label for wireless communication technology To scan and decode a barcode, you need to press the trigger switch. The scanner emits a laser beam through the optical window while scanning a barcode.
4.2 CHG-4001 (Dedicated cradle for the OPI-4012, optionally sold) Name 1. Serial Label 2. Electrical Terminal (+) 3. Electrical Terminal (―) 4. DC Jack 5. AC Adapter Cable Guide Functions Charging terminals are used to supply power to the scanner from a dedicated cradle (CHG-4001). Connect a dedicated AC adapter. Install a dedicated AC adapter cable along the guide.
5.Getting Started About the OPI-4012 The OPI-4012 scanner is set to low power mode by default. Please press and hold down the trigger switch for a while to activate the scanner. The scanner will not operate if the main battery is empty. Please charge the main battery using a dedicated AC adapter before getting started. It is also possible to charge the main battery using a dedicated cradle (CHG-4001).
Charging the scanner (its main battery) on the CHG-4001 cradle Scanner on the cradle Concave (凹) Switch for terminal detection Electrical contacts Replacing battery 12
6.Scanning Barcodes During a scan, the green LED patterns shown below will be visible. These patterns assist you in aiming the scanner; they are superimposed on the illuminated scan field. The aiming patterns are only a guide. They do not indicate exact scannable width or distance between a scanner and a barcode.
7.Wireless Communication 7.1 Wireless Specifications ・The OPI-4012 communicates using Bluetooth (Ver 2.0) wireless communication technology. The OPI-4012 supports SPP (serial port profile) and communicates with other Bluetooth devices which support the same profile.
7.2 Menu Barcode for the Configuration ・Use menu barcodes to configure the following settings of the scanner: 9 Please carry out the configuration before making a Bluetooth connection. 9 Please refer to the Universal Menu Book for details.
■ Handshaking Settings ・You can set the handshaking for the communication between the host and the scanner. ・When it is set to “No handshaking”, the reliability of the transmitted data will be lower. It is recommended to enable ACK/NAK. 9 ACK/NAK No Response 9 ACK/NAK ■ ACK/NAK Timeout Settings ・You can set the timeout for the ACK/NAK sent from the host.
9 The scanner will not carry out the scanning operation if the data memorizing setting is disabled. 9 Auto reconnect feature will operate in every 20 seconds. ■ Trigger Connection ・You can set the scanner to connect or disconnect by pressing down the trigger key for the set duration. ■ Press trigger switch time to connect ・This is the time the trigger switch needs to be pressed where after the scanner tries to establish a connection.
8.How to Configure the Wireless Communication Settings 8.1 Connect without Authentication 1. Use the universal menu book to set the scanning options and read options of the scanner. ・This operation will not be necessary if you would like to use the scanner with the default settings. 2. Use this instruction manual to set the communication settings. ・Scan the menu barcode “Connect to PC”. (The trigger connect option will be enabled.) ・Scan the numbers and characters of the 12-digit Bluetooth device address.
8.2 Connect with Authentication 1. Use the universal menu book to set the scanning options and read options of the scanner. ・This operation will not be necessary if you would like to use the scanner with the default settings. 2. Use this instruction manual to set the communication settings. ・Scan the menu barcode “Connect to PC”. (The trigger connect option will be enabled.) ・Scan the numbers and characters of the 12-digit Bluetooth device address using the attached list of menu barcodes.
■Notes ・The scanner does not scan any barcodes other than menu barcodes before it is connected to the Bluetooth device. (If the [BM1] settings are configured, the scanner will scan other barcodes.) ・If you scan a 12-digit barcode label before connecting the scanner to the Bluetooth device, the scanner will acknowledge the 12-digit barcode as a Bluetooth device address.
9.Default Settings * Refer to the Product Specification Manual and the Universal Menu Book for the readable codes. 9.
9.
9.2 Default Settings 2: Read Options, Trigger, Buzzer, LED settings Parameter Default Settings Setting the number of characters Read mode Inter-character gap check (NM-7) Fixed length OFF all codes Multiple read Character *1 > Inter-character gap Multiple columns read (barcode only) Trigger switch Read time Buzzer durations Buzzer tone Buzzer loudness LED indicator duration Disabled Enabled 2 seconds 200 msec 3kHz+2.5kHz Loud 200 msec 9.
CODE39 labels SET ZZ CNPC Connect to PC CNCR Connect to Cradle Connect to END ZZ _Z7_ _CNPC_ _CNCR_ _ZZ_ CODE39 labels SET Bluetooth address setting END ZZ BDAS Set Bluetooth address BDAE End Bluetooth address ZZ QR code label _ZZ_ _BDAS_ _BDAE_ _ZZ_ 25 QR code label
Barcode for Bluetooth address setting 0 1 2 3 4 5 6 _Q0_ 9 _Q9_ A _0A_ B _0B_ C _0C_ D _0D_ E _0E_ F _0F_ _Q1_ _Q2_ _Q3_ _Q4_ _Q5_ _Q6_ 7 _Q7_ 8 _Q8_ Flow : [ZZ]⇒[BDAS]⇒[12Digit Bluetooth address]⇒[BDAE]⇒[ZZ] In case reading wrong address, restart from reading [BDAS] 26
CODE39 labels SET ZZ AUTE Enable AUTD Disable Authentication END ZZ _ZZ_ _AUTE_ _AUTD_ _ZZ_ CODE39 labels SET ZZ ENCE Enable ENCD Disable Encryption END ZZ QR code label _ZZ_ _ENCE_ _ENCD_ _ZZ_ 27 QR code label
CODE39 labels SET ZZ PINS 0 1 2 3 4 PIN code 5 6 7 8 9 PINE END ZZ _ZZ_ _PINS_ _Q0_ _Q1_ _Q2_ _Q3_ _Q4_ _Q5_ _Q6_ _Q7_ _Q8_ _Q9_ _PINE_ _ZZ_ Set PIN code setting End PIN code setting 28 QR code label
CODE39 labels SET ZZ ENAU Enable DIAU Disable Auto connect END ZZ QR code label _ZZ_ _enau_ _diau_ _ZZ_ Manually connect +-CONN-+ Manually disconnect +-DISC-+ _+-CONN-+_ _+-DISC-+_ CODE39 labels SET ZZ Default SO END ZZ _ZZ_ _SO_ _ZZ_ ] ] OPTOELECTRONICS Co., Ltd.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.