Portable 2D Data Collector PX-20 The PX-20 is a portable data collector with a 2D barcode scanner. Scanned and stored data can be transmitted to the host via the USB interface, or via Bluetooth.
Opticon PX-20 Specifications Manual Preliminary. All information subject to change without notice. Document History Model Number: PX-20 Edition: 1.3 Date: 2013-05-30 Copyright 2013 Opticon. All rights reserved. This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon.
Opticon PX-20 Specifications Manual Contents 1. Abstract .....................................................................................................................................5 2. Overview ................................................................................................................................... 5 3. Physical Features ..................................................................................................................... 6 3.1. Dimensions ................
Opticon PX-20 Specifications Manual 12. Packaging Specifications....................................................................................................... 21 12.1. Individual Packaging Specification................................................................................... 21 12.2. Collective Packaging Specification .................................................................................. 22 13. Durability .......................................................................
Opticon PX-20 Specifications Manual 1. Abstract This manual provides specifications for the PX-20 portable 2D barcode data collector. 2. Overview The PX-20 is a very compact data collector with a built-in 2D barcode scanner. Due to its compact size and its Bluetooth capabilities, the PX-20 is the ideal companion scanner for mobile devices like the iPhone/iPad and Android telephones and tablets.
Opticon PX-20 Specifications Manual 3. Physical Features 3.1.
Opticon PX-20 Specifications Manual 3.2. Weight 40 g (estimated) 3.3. Color Black 4. Environmental Specifications 4.1. Operating Temperature and Humidity Temperature: -10 to 50° C (Charging temperature range 0 to 45° C) Humidity: 20% to 90% RH 4.2. Storage Temperature and Humidity Temperature: -20 to 60° C Humidity: 20% to 85% RH 4.3.
Opticon PX-20 Specifications Manual 5. Component Specification Item Specifications Notes 2D Engine MDI-3100 Opticon’s 2D imager with integrated high speed decoder Application processor: Renesas RX62N 96 MHz Clock speed 1 MByte serial flash Barcode storage + >50,000 barcodes + time stamp. Might be used for other purpose as well, depending on the users application. 512Kbyte program flash 128Kbyte available for user applications 32Kbyte config flash For configuration storage (e.g.
Opticon PX-20 Specifications Manual 6.3. Electrical Characteristics Parameter Operating current Symbol Typ Max Unit While Scanning IOP 350 400 mA While in Standby IPRE 45 50 mA While Charging ICHG1 350 400 mA Ioff 100 150 μA 2.75 3.7 4.2 V 350 355 - mAh When OFF Voltage VBAT Rated capacity Battery specifications Min Charging current ICHG2 Charging time Tchg - - 2.
Opticon PX-20 Specifications Manual 7. Optical Specifications Item Characteristics Scan method CMOS area sensor (black and white) Nr of effective pixels 752 (H) x 480 (V) Dots Image capture speed (*1) 60 fps Frames per second Focal distance 130 mm Horizontal 40.6° Vertical 26.
Opticon PX-20 Specifications Manual 8. Barcode reader Technical Specifications Scanning is done by pointing the PX-20’s aiming light to the center of a bar code for scanning. The conditions for technical specifications are as follows, unless otherwise specified in each section.
Opticon PX-20 Specifications Manual 8.1. Bar Code Test Sample 1 D Bar Codes Resolution 0.127 mm (5mil) 0.20 mm (7.9mil) 0.254 mm (10mil) 0.508 mm (20mil) Symbology PCS Code 39 0.9 Resolution 0.20 mm (7.9mil) Symbology Code 128 Resolution 0.330 mm (13mil) Resolution 0.15 mm (6mil) Size (mm) 32 × 10 100 × 10 32.5 × 10 36 × 25 No. of Digits 15 31 7 4 PCS 0.9 Size (mm) 42 × 10 No. of Digits 16 Symbology 12-digit UPC PCS 0.9/0.3 Size (mm) 31.5 × 25.0 No.
Opticon PX-20 Specifications Manual 8.2. Scan Area and Depth of Field The scan area is measured from the front edge of the camera module. 100 50 250 200 150 300 0.127(5mil) 90 Code 39 130 210 0.508(20mil) * 65 Code 128 [ Unit : mm ] 0.254(10mil) 70 0.20(7.9mil) 80 300 190 0.33(13mil) UPC 100% 225 55 0.169(6.7mil) 85 145 PDF417 0.254(10mil) 65 200 0.212(8.4mil) 95 QR Code 0.381(15mil) 60 Data Matrix 120 80 0.
Opticon PX-20 Specifications Manual Figure 3: Scan Area and Depth of Field 8.3. Print Contrast Signal PSC 0.3 or higher MRD Distance Bar Code Sample : 32% and higher (70% or higher reflectivity of space and quiet zone) : 130 mm from the front edge of the camera module : UPC specified in Chapter 8. (Resolution: 0.33 mm, PCS: 0.3) MRD = Minimum reflectance of white bar - Maximum reflectance of black bar PCS = Error! 8.4. Minimum Resolution 1D Code GS1-Databar Stacked Code 2D Code : 0.
Opticon PX-20 Specifications Manual 8.6. Motion Tolerance UPC bar code 100% can be read when it is moving at 2m/s. Ambient Temperature and Humidity Ambient Light Distance Angles Skew Tilt Curvature Power Supply Voltage PCS (1D and 2D) Bar Code Sample : Room temperature and Room humidity : 500 lux to 1000 lux (on the surface of a bar code) : 130 mm from the front edge of the camera module : α= 0° : β = 15° : γ = 0° :R=∞ : 3.3 and 5.0 V : 0.9 or higher : UPC with 0.
Opticon PX-20 Specifications Manual 8.7. Pitch, Skew, and Tilt Pitch Skew Tilt : α = ±50° : β = ±50° : γ = ±180° Bar Code Sample : 0.33 mm UPC specified in Chapter 8 Distance : 130 mm from the front edge of the camera module Curvature :R=∞ For the pitch angle and tilt angle measurement, set the skew angle β = +15° α β - + - + γ + - Figure 6: Pitch, Skew, and Tilt 8.8. Curvature 0.33 mm 12-digit UPC 0.
Opticon PX-20 Specifications Manual Interface Specifications 9. External interfaces 9.1. USB-HID and USB-VCP Interface Specifications Complies with USB Version 2.0. The supported profiles are USB-COM (also referred to as USB-VCP that stands for Virtual Communication Port). This port is used for charging and data communication. 9.2. Wireless Interface PX-20 has a BT connection with the following features: Feature Description Version 1) 2.
Opticon PX-20 Specifications Manual 10. Cable and Connector 10.1. USB Cable A dedicated USB cable is provided. This cable has a USB-A connector on one end and a micro-USB B connector on the other end. 10.2. Connector Contact Number Signal Name 1 VCC 2 -DATA 3 +DATA 4 Ext trig 5 GND Figure 2: USB Micro-B connector 10.3. External trigger It is possible to trigger the PX-20’s barcode reader externally via a pin in the USB connector.
Opticon PX-20 Specifications Manual 11. Labeling 11.1. Product label The product label shown below is affixed to the scanner. Figure 3: Product label The serial number consists out of 6 numeric digits. It starts with 000001 and is incremented with 1 for each scanner. The serial number is also stored in the scanners non-volatile memory and API functions are available to retrieve the serial number for use in user applications. Material: Base + laminate protection against wear.
Opticon PX-20 Specifications Manual Figure 4: White box label 20
Opticon PX-20 Specifications Manual 12. Packaging Specifications 12.1. Individual Packaging Specification Put the scanner in a protective foam bag and place it in an individual packing box.
12.2.Collective Packaging Specification Size of the shipping box is: 500 0JV) x 560 (D) x 200 (H) mm Carton Box Pack 100 sets into the carton box A:Barcode seriallabelfor packing box Stick the labels on both front and back side of the box C/No • B:Missing serialnumber label Attach this label when more than two serialnumbers are out of sequence.
Opticon PX-20 Specifications Manual 13. Durability 13.1. Drop Test No malfunction occurred after the following drop test. Drop Test: Drop the data collector from a height of 180 cm onto a concrete floor (three times in each of 6 angles).
Opticon PX-20 Specifications Manual 14. Regulatory Compliance 14.1. Product Safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011 Lamp classification: IEC62471:2006 Exempt Group 14.2. EMC EN55022 EN55024 FCC Part 15 Subpart B Class B and Part 15 Subpart C: This device complies with part 15 of the FCC Rules.
Opticon PX-20 Specifications Manual 14.5. R&TTE This scanner conforms to the following standards of the Radio and Telecommunications Terminal Equipment (R&TTE) directive from the EU.
Opticon PX-20 Specifications Manual 15. Handling Handle this product carefully. Do not deliberately subject it to any of the following. 15.1. Shock Do not throw or drop the scanner. Do not drop or put heavy items on this product or its cable. 15.2. Temperature Conditions Do not use the scanner at temperatures outside the specified range. Do not use near heat sources such as radiators, heat registers, stoves, or other types of devices that produce heat.
Opticon PX-20 Specifications Manual 16. Revision History Revision Date Issued By 0.1 20120928 NiLe 0.2 20121010 NiLe 0.3 20121012 NiLe 0.4 20121015 NiLe 0.5 20121030 NiLe 0.6 20121123 NiLe 0.7 20121130 NiLe 1.0 20121221 NiLe 1.1 20130109 NiLe 1.2 20130125 Kees 1.