Data Collector with GPS & Bluetooth OPL-9813 The OPL-9813 is a laser data collector featuring GPS (Global Positioning System) feature, Bluetooth 2.1 communication and time stamp functionality.
Opticon OPL-9813 Specifications Manual All information subject to change without notice. Document History Model Number: OPL9813 Rev: 4 Date: 7-11-2014 Created: 19-9-2011 Changes: Changed battery and labeling Copyright 2014 Opticon. All rights reserved. This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon.
Opticon OPL-9813 Specifications Manual Contents 1. Abstract ..................................................................................................................................... 6 2. Overview ................................................................................................................................... 6 3. Physical Features ..................................................................................................................... 7 3.1. Dimensions ............
Opticon OPL-9813 Specifications Manual 9.3. GPS ................................................................................................................................ 16 9.3.1. Module ..................................................................................................................................... 16 9.3.2. Receiving Frequency ............................................................................................................... 16 9.3.3. Receiving Channel ........
Opticon OPL-9813 Specifications Manual Table of Figures Figure 1: Ambient Light Immunity................................................................................................ 8 Figure 2: Depth of field ............................................................................................................. 11 Figure 3: Pitch .......................................................................................................................... 12 Figure 4: Skew and dead zone ...............
Opticon OPL-9813 Specifications Manual 1. Abstract This manual provides specifications for the OPL-9813 barcode data collector. 2. Overview The OPL-9813 is a barcode data collector that contains a compact laser module. This data collector offers efficient scanning performance that is suitable for various business environments and is able to store scanned data and data configured via keyboard input. Infra-red radiation communication is one of communication functions of the OPL-9813.
Opticon OPL-9813 Specifications Manual The OPL-9813 can use a variety of cradles: • CRD 9723 single bay cradle (1 x charging, 1 x communication) • CRD 9723 multi bay cradle (5 x charging, 1 x communication) • CRD 9723 multi bay cradle (5 x charging, 5 x communication) • CRD 9722 single bay cradle (1 x charging, no communication) • CRD 9726 single bay cradle with build-in telephone modem. • CRD 9727 single bay cradle with build-in GSM modem.
Opticon OPL-9813 Specifications Manual 4.5. Ambient Light Immunity Decoding performance is guaranteed when the range of illumination on a barcode surface is between zero and the following values: Incandescent light 3,000 lx Fluorescent light 3,000 lx Sunlight 50,000 lx Figure 1: Ambient Light Immunity Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS: 0.9 Resolution: 0.25 mm Symbology: 8-digit Code 39 Quiet Zone: 10 mm N/W Ratio: 1:2.
Opticon OPL-9813 Specifications Manual 5. Controls Item Specifications Controls External memory Remarks MPU 32-bit microprocessor Built-in ROM 512 KB Built-in RAM 64 KB Flash ROM 512 KB (Option: Max. 4 MB) SRAM 512 KB (Option: Max.
Opticon OPL-9813 Specifications Manual 7. Optical Specifications 7.1. Laser Scan Specifications Parameter Specification Unit Light-emitting element Red laser diode — Emission wavelength 650 ±10 (25° C) nm Light output 1.0 or less mW Scanning method Bi-directional vibration mirror — Scanning speed 100 ±20 scans/s Scan angle Scan angle: 54 ±5 ° Read angle: 44 (Min) ° 0.
Opticon OPL-9813 Specifications Manual 8.3. Scan Area and Resolution 8.3.1. Depth of Field The depth of field is measured from the edge of the data collector. The scanning range is within the circular arc centered on the scan origin. Figure 2: Depth of field Symbology Resolution (mm) Decode Depth (mm) PCS Code 39 1.0 60–300 0.9 Code 39 0.5 35–210 0.9 Code 39 0.25 35–120 0.9 Code 39 0.15 35–70 0.9 Conditions Barcode Sample: OPTOELECTRONICS Test Sample N/W ratio: 1:2.
Opticon OPL-9813 Specifications Manual Resolution Symbology PCS Quiet Zone Digit 1.0 mm Code 39 0.9 25 mm 1 0.5 mm Code 39 0.9 18 mm 3 0.25 mm Code 39 0.9 10 mm 8 0.15 mm Code 39 0.9 7 mm 10 Note: dirt or scratches on the mask will degrade scanning performance. Always handle the data collector carefully. 8.4. Pitch, Skew, and Tilt 8.4.1.
Opticon OPL-9813 Specifications Manual 8.4.2. Skew Angle and Dead Zone Skew angle: β = ±50° (Excluding dead zone) Dead zone: β = ±8° (There are some areas in which decoding fails due to specular reflection) Figure 4: Skew and dead zone Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance: 90 mm from the edge of the data collector Label: Pitch, Skew Angle PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2.5 Dead Zone, Tilt Angle PCS = 0.
Opticon OPL-9813 Specifications Manual γ γ=20° =20° 8.4.3. Tilt Angle γ = ±20° Figure 5: Tilt angle Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance: 90 mm from the edge of the data collector Label: Pitch, Skew Angle PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39, Quiet Zone = 10 mm, N/W Ratio = 1:2.5 Dead Zone, Tilt Angle PCS = 0.9, Resolution = 0.
Opticon OPL-9813 Specifications Manual 8.5. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R ≥ 20 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R ≥ 25 mm. Figure 6: Curvature Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm Distance: 90 mm from the edge of the data collector Angle: Skew Angle β = +15° The scanning range will vary according to the depth of field. 9.
Opticon OPL-9813 Specifications Manual 9.2.2. Transmission Speed Default transmission speed is set at 115.2 kbps. Other supported baud rates are 57.6 kbps, 38.4 kbps, 19.2 kbps, 9600 bps, 4800 bps, and 2400 bps. 9.3. GPS 9.3.1. Module The OPL-9813 is equipped with a GPS (Global Positioning System) module plus a compact patch antenna (15 mm X 15 mm) 9.3.2. Receiving Frequency 1575.42MHz (L1 C/A Code) 9.3.3. Receiving Channel 66 channels (max) 9.3.4. Sensitivity Acquisition -148 dBm Tracking -165 dBm 9.3.5.
Opticon OPL-9813 Specifications Manual 10. Serial Number 10.1. Dimensions and location. Below is the product label with serial number.
Opticon OPL-9813 Specifications Manual 10.2. Detailed drawing Figure 8: Name plate and serial number details 10.3. Serial number Bar code: Standard Code 39 plus human readable text printed below the bar code. Bar code height: 4mm Bar code data: The serial number. This should match that of the OPL-9813 in the box. The serial number consists out of 6 digits, starts with 000001 and is incremented with one every unit that is produced.
Opticon OPL-9813 Specifications Manual 11. Packaging Specifications 11.1. Individual Packaging Specification Put the data collector in a protective foam bag and place it in an individual packing box, then place the accessories into the box. Close the box and affix a label to the side of the box.
Opticon OPL-9813 Specifications Manual 11.2. Accessory Specification These accessories are enclosed in an individual package: • 1 hand strap 11.3. Collective Packaging Specification Put 150 individually packaged data collectors in a collective packing box. Dimensions (after assembly): 615 mm (W) by 520 mm (D) by 277 mm (H).
Opticon OPL-9813 Specifications Manual 12. Durability 12.1. Drop Test (without packaging) No malfunction occurred after the following drop test. Drop Test: Drop the data collector from a height of 150 cm onto a concrete floor. Each side of the data collector impacted the floor three times. Figure 11: Drop test 12.2.
Opticon OPL-9813 Specifications Manual 13. Reliability MTBF (Mean Time Between Failures) of this product is 10,000 hours. 14. Regulatory Compliance 14.1. Laser Safety The data collector emits laser beams. JIS C6802: 2005: Laser class 2 IEC 825-1/EN 60825-1: Laser class 2 FDA CDRH Laser class II. Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice No. 50 dated June 24, 2007. Class II laser devices are not considered to be hazardous when used for their intended purpose.
Opticon OPL-9813 Specifications Manual 14.3. RoHS RoHS: The restriction of the use of certain hazardous substances in electrical and electronic equipment, 2002/95 EC. 14.4. State of California: Perchlorate Best Management Practices The batteries on some Opticon products may contain Perchlorate.
Opticon OPL-9813 Specifications Manual 15. Safety Handle this product carefully. Do not deliberately subject it to any of the following. 15.1. Shock Do not throw or drop the data collector. Do not drop or put heavy items on this product. 15.2. Temperature Conditions Do not use the data collector at temperatures outside the specified range. Do not use near heat sources such as radiators, heat registers, stoves, or other types of devices that produce heat.
Opticon OPL-9813 Specifications Manual 16.