No.59-1501-0 INSTALLATION INSTRUCTIONS High Mount Outdoor Detector N219 HX -40/40AM CONTENTS (1) INSTALLATION HINTS (2) PARTS IDENTIFICATION (3) KNOCKOUTS (4) DETECTION AREA SETTING (5) INSTALLATION (6) BRACKET INSTALLATION AND ADJUSTMENT (7) WIRING (8) FUNCTION SETTING (9) OPERATION TEST (10) LED FUNCTIONS (11) SPECIFICATIONS By utilising the OPTEX’s unique pyro-element, HX series achieves high reliable detection performance against false and missed alarms.
PARTS IDENTIFICATION Bracket base Base Screw (3×10 mm) Terminals Main unit Hood PIR sensor (Don not touch) Anti-masking infrared LED (HX-40AM only) Bracket Shaft cover Screw (4×20 mm) Lock screw (M4×35 mm) 䎃 Lens Cover 䎃 䎃 䎃 䎃 䎃 LED indicator Lock screw 䎃 3 Area masking seal KNOCKOUTS 3-B Bracket 3-A Main unit Wiring Hole (Off-the-shelf) magnet switch installation position For hood fastening Wiring Hole Wiring knockout Wiring sponge pad Don’t touch For bracket up-down lock screw
4 DETECTION AREA SETTING 4-A Detection Area Side view of detection area (Installation height 3.0 m (1 ft.) ) Top view of detection area 12 m (40 ft.) 10° 20° 30° 40° 3.0 m (10 ft.) 8m (26.7ft.) 90° (Installation height 2.5 m) 0 2.5 m (8.3 ft.) 12 m (40 ft.) 8m (26.7ft.) 12 m (40 ft.) 4-B Detection Length Adjustment To limit the detection distance, apply the appropriate masking seal. Note that there are three different types of seal.
6 BRACKET INSTALLATION AND ADJUSTMENT Using the bracket makes it possible to adjust the unit through 180° degree. In cases where the ground is uneven and therefore not parallel with the base of the unit, it is possible to adjust the unit vertically by +/- 20 degree (see section 6-B) Caution>> Do not change the detection distance with bracket. Use the masking seal to adjust the detection distance. 90° 90° 20° 20° 6-A Bracket installation 1 Push the shaft cover clip outwards to remove the cover.
Tighten the adjustment screw. 8 Using 6-B as reference, adjust the updown orientation, then tighten the lock screw. 9 Fit the shaft cover into place. Adjustment screw 6 Wire to the terminal and install the Main unit and lens on the base. 7 On the Main unit, make the settings and check operation. Caution>> Once the operation checks are complete, fit the shaft cover into place. When the Main unit is fastened to the bracket, you can not remove the shaft cover.
TAMPER (NC) AUX INPUT (NC) TROUBLE SP OUTPUT T.O.(NC) SP POWER INPUT (+) (9.5 - 18VDC) POWER INPUT (–) (9.5 - 18VDC) ALARM OUTPUT (N.C.) HX-40AM ALARM OUTPUT (COM) ALARM OUTPUT (N.O.) SPARE (Non short) TROUBLE OUTPUT (N.C.) AUX INPUT (N.C.) WIRING TAMPER OUTPUT (N.C.) *1 7 NO COM NC – + ALARM POWER 9.5-18VDC HX-40 TAMPER (NC) AUX INPUT (NC) SP SP NO COM NC – + ALARM POWER 9.5-18VDC *1: TAMPER terminals to be connected to a 24 hour supervisory loop.
8 FUNCTION SETTING Dip SW 1 LED ON/OFF SELECTOR 2 PULSE COUNT SELECTOR 3 EXTERNAL SENSOR INPUT SELECTOR 4 TROUBLE OUTPUT SELECTOR (8-A) (8-B) (8-C) (8-D) ANTI-MASKING SENSITIVITY SELECTOR (8-F) PIR SENSITIVITY SELECTOR (8-E) Do not touch 8-A LED ON/OFF Dip switch ON HX-40 HX-40AM FUNCTION POSITION OFF 1 ON (factory default) The LED lights when someone is detected. The LED does not light even if someone is OFF detected NOTE: For the walk test, move more than 1 m (0.3 ft.
-D TROUBLE OUTPUT OFF ON Dip switch 4 HX-40 HX-40AM Trouble output is used for anti-masking signal. When an object is placed close to the lens surface, for a period of more than 180 seconds, the IR Anti-Masking circuit will activate and generate a trouble signal. OUTPUT TERMINAL POSITION ON (factory default) TROUBLE OFF TROUBLE and ALARM Use this when not wiring a dedicated trouble input terminal on the control panel.
OPERATION TEST 9-A Example of adjustment for false alarms If there is a road where people or vehicles can pass in front of the detection area, and can trigger false alarms, adjust the area as follows. 1 Delete the unneccesory detection area (a) using the appropriate masking seal(s) 1 2 or 3. b (Reduce the distance fromo 12m, 9m, 5.5m ,4m (40ft., 30ft., 18.3ft., 13.3ft.) as determined by the walk testing.
9-B Area Masking To limit the detection range, apply the area masking seal to the section you want to hide on the lens inside. Configure the area in such a way as to avoid having anything cut across the area. Pasting on example for masking No. 5 and No.
SPECIFICATIONS Model HX-40 Detection method PIR Coverange Distance limit HX-40 AM Passive infrared 12 m (40 ft.) 85° wide / 94 zones 4 m, 5.5 m, 9 m, 12 m (13 ft, 18 ft, 30 ft, 40 ft.) Detectable speed 0.3 – 1.5 m/s (1 – 5 ft/s) Sensitivity 2.0°C (3.6°F) at 0.6 m/s 9.5 – 18VDC Power input Current draw 35 mA (max) at 12VDC Approx. 60 sec(LED blinks) Warm-up period Form C 28VDC 0.2A max Alarm output N.C. 28V DC, 0.1A max Tamper output Trouble output N.C. 28V DC, 0.1A max – N.C.
DIMENSIONS Using bracket and hood Without bracket and hood 148(5.8) 266(10.5) 92(3.6) 205(8.1) 197.5(7.8) 99(3.9) Unit:mm (inch) Unit:mm (inch) WARRANTY 5 year replacement warranty The HX-40 series is designed to detect movement of an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept complete responsibility for any damages or other consequences resulting from an intrusion.