M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 ONYX-MD116 11.6” LCD with LED Backlight Intel® Apollo Lake processor Dual smart card readers for multiple-care workflow Instant vehicle docking system Mobile Medical Assistant ONYX-MD116 Manual 1st Ed June.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 Copyright Notice This document is copyrighted, 2017. All rights are reserved. The original manufacturer reserves the right to make improvements to the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of the original manufacturer.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 Acknowledgments Intel® PentiumTM is registered trademarks of Intel® Corporation. Microsoft® Windows is a registered trademark of Microsoft® Corporation. All other product names or trademarks are properties of their respective owners.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 Packing List Before you begin installing your Mobile Medical Assistant, please make sure that the following items have been shipped: ONYX-MD116 Mobile Medical Assistant ONYX-MD116 Docking Station Four VESA Screws(M:4mm x P:0.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 If any of these items are missing or damaged, you should contact your distributor or sales representative immediately. Headquarters Onyx Healthcare Inc. 2F, No.135, Lane 235, Pao-Chiao Rd., Hsin-Tien City, Taipei 231, Taiwan, R.O.C. TEL: +886-2-8919-2188 FAX: +886-2-8919-1699 E-mail: sales@onyx-healthcare.com http://www.onyx-healthcare.com Worldwide Offices: Onyx Healthcare Inc. 2F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 Email: usasales@onyx-healthcare.com Onyx Healthcare EUROPE B.V. Primulalaan 42, 5582 GL Waalre, Netherlands Tel : +31-(0)499-745600 Email: eusales@onyx-healthcare.com Onyx Healthcare (Shanghai) INC. 20F, unit D, GEM Building, No. 487 Tianlin Road, Shanghai, China Tel: +86-021-64956588 Fax: +86-021-64956889 Email: cnsales@onyx-healthcare.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 Safety & Warranty 1. Read these safety instructions carefully. 2. Keep this user's manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Do not use liquid or spray detergents for cleaning. Use a damp cloth. 4. For pluggable equipment, the power outlet must be installed near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 12. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient over-voltage. 13. Never pour any liquid into an opening. This could cause fire or electrical shock. 14. Never open the equipment. For safety reasons, only qualified service personnel should open the equipment. 15. Warning: Do not modify this equipment without authorization of the manufacturer.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 16. If any of the following situations arises, get the equipment checked by service personnel: a. The power cord or plug is damaged. b. Liquid has penetrated into the equipment. c. The equipment has been exposed to moisture. d. The equipment does not work well, or you cannot get it to work according to the users manual. e. The equipment has been dropped and damaged. f. The equipment has obvious signs of breakage. 17.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 Classification 1. Degree of production against electric shock: not classified 2. Degree of protection against the ingress of water: IPX0 3. Mode of operation: Continuous 4. Type of protection against electric shock: Class I equipment 5.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 FCC This device complies with Part 18 FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 UL Module Description ONYX-MD116 module is developed to suitable for the Classification Mark requirement
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 Safety Symbol Description The following safety symbols are the further explanations for your reference. MEDICAL – GENERAL MEDICAL EQUIPMENT AS TO ELECTRICAL SHOCK, FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH ANSI/AAMI ES 60601-1 (2005) + AMD (2012) and CAN/CSA-C22.2 No. 6060-1 (2014). Attention, consult ACCOMPANYING DOCUMENTS. Stand-by Ground wire Protective Ground wire.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 Contents Chapter 1 General Information 1.1 Introduction .................................................................... 1-2 1.2 Feature ............................................................................ 1-3 1.3 Specification ................................................................... 1-4 1.4 Dimension ....................................................................... 1-8 Chapter 2 Hardware Installation 2.
M o b i l e M e d i c a l As s i s t a n t ONYX-MD116 Chapter 1 General Information
Slim Medical Panel PC ONYX-MD116 1.1 Introduction ONYX-MD116 Mobile Medical Assistant is based on Intel® PentiumTM N4200 Quad Core processor, which delivers a performance improvement of more than 100 percent compared to systems running traditional single-core processors. With four cores computing engines, ONYX-MD116 can simultaneously execute four computing tasks. It accommodates one M.2 2242 Interface SATA SSD and one DDRIII SODIMM up to 16GB.
Slim Medical Panel PC ONYX-MD116 1.
Slim Medical Panel PC ONYX-MD116 1.3 Specification Hardware Specifications Processor Processor Intel® Apollo Lake Processor System Memory DDR3L SO-DIMM x1, Default 4 GB (Up to 16 GB) OS Support Microsoft® Windows 10 Storage M.2 Interface x1, Default 64 GB Wireless 802.11 a/b/g/n + BT4.
Slim Medical Panel PC ONYX-MD116 Battery Run Time Approx. 5 hrs Speaker 3W x1 LCD Specifications Display Type 11.6” LCD Max. Resolution 1920 x 1080 Contrast Ratio 800:1 Luminance (cd/m2) 600TYP) Back Light Life Time >50,000 Hrs Note: All ONYX LCD products are manufactured with High precision technology. However, there are a small number of defective pixels in all LCD panels that are not able to change color.
Slim Medical Panel PC ONYX-MD116 Mechanical Specifications Architecture Close-frame Color Dark Gray Mounting / Holder VESA 75/100mm, Screw type:M4*8mm Construction 3mm ABS + PC TYPE Plastic housing Rear cover magnesium Dimension (WxHxD) 312 (W) x 239 (H) x 37 (D) mm Net Weight Approx. 1.8 kg Power Supply Specifications Model Adapter FSP096-AHAN2 Input Voltage 100-240V AC @ 50-60 Hz Output Voltage 12V, 5A, 96W max.
Slim Medical Panel PC ONYX-MD116 Environmental Specifications Operating Temperature -10°C ~ 55°C (14°F ~ 131°F) Operating Humidity 30% to 75% RH, non-condensing Operating Pressure 700 to 1060 hPa Storage Temperature -20°C ~ 60°C (-4°F ~ 140°F) Storage Humidity 10%~95%@35°C, non-condensing Storage Pressure 700 to 1060 hPa Vibration 0.5G / 5 ~ 500Hz (Random) / operation Shock 20G peak acceleration (11 msec.
Slim Medical Panel PC ONYX-MD116 USB USB 3.0 (Type-A) x1, USB 2.
Slim Medical Panel PC ONYX-MD116 1.
Slim Medical Panel PC ONYX-MD116 Chapter 2 Hardware Installation Chapter 2 Hardware Installation 2-1
Slim Medical Panel PC ONYX-MD116 2.1 Safety Precautions Always completely disconnect the power cord from your board whenever you are working on it. Do not make connections while the power is on, because a sudden rush of power can damage sensitive electronic components. Always ground yourself to remove any static charge before touching the board. Modern electronic devices are very sensitive to static electric charges. Use a grounding wrist strap at all times.
Slim Medical Panel PC ONYX-MD116 2.2 Quick Tour of ONYX-MD116 Before you start to set up ONYX-MD116, take a moment to become familiar with the locations and purposes of the controls, drives, connections and ports, which are illustrated in the figures below. When you place ONYX-MD116 upright on the desktop, its front panel appears as shown in Picture 2-1. Picture 2.
Slim Medical Panel PC ONYX-MD116 When you turn the Mobile Medical Assistant around and look at its rear cover, the I/O port in left and right side, as shown in Picture 2-2. (The I/O section includes various I/O ports, including a DC-IN Jack, 1 Ethernet ports, 2 USB ports.). Top side have 2 smart card reader. Picture 2.
Slim Medical Panel PC ONYX-MD116 Below picture 2-3/2-4 show the Docking front and rear view. In front view have 2 USB port and Battery charging hole. Back side have DC-IN Jack and phoenix connector/ Line-out/ RJ 45 port. Picture 2.
Slim Medical Panel PC ONYX-MD116 Picture 2.
Slim Medical Panel PC ONYX-MD116 2.3 Mounting ONYX-MD116 Docking be mounted with 75mm x 75mm or 100mm x 100mm VESA holes in the rear cover by wall-mount or desktop stand. VESA Holes 2.4 Turn On and Boot up into Windows OS This section is for Windows operating system only. If you are installing a different operating system, please contact your vendor for installation details. Your ONYX-MD116 will begin loading Windows OS once you push the power button to turn power on.
Slim Medical Panel PC ONYX-MD116 2.5 Turn off Turning off ONYX-MD116 properly is important for system reliability. There are two ways to turn off the system. 1. On the start menu, click “shut down” and select “OK” 2. Push the power button and then the system will shut down automatically 2.6 Connectors 1. USB 2.0 port These 4-pin Universal Serial Bus (USB) ports are available for connecting USB 2.0 devices. 2. USB 3.0 These 9 Universal Serial Bus (USB) ports are available for connecting USB 3.
Slim Medical Panel PC ONYX-MD116 Chapter 3 Driver Installation Chapter3 Driver Installation 3-1
Slim Medical Panel PC ONYX-MD116 There are several installation ways depending on the driver package under different Operating Systems.
Slim Medical Panel PC ONYX-MD116 Appendix A Miscellanea Appendix A Miscellanea A-1
Slim Medical Panel PC ONYX-MD116 A.1 General Cleaning Tips You may need the following precautions before you begin to clean the computer. When you clean any single part or component for the computer, please read and understand the details below fully. 1. Never spray or squirt the liquids directly onto any computer component. If you need to clean the device, please rub it with a piece of dry cloth. 2.
Slim Medical Panel PC ONYX-MD116 void the warranty. A.2 Cleaning tools Although many companies have created products to help improve the process of cleaning your computer and peripherals users can also use household items to clean their computers and peripherals. Below is a listing of items you may need or want to use while cleaning your computer or computer peripherals.
Slim Medical Panel PC ONYX-MD116 circuitry to corrode. Cotton swabs - Cotton swaps moistened with rubbing alcohol or water are excellent tools for wiping hard to reach areas in your keyboard, mouse, and other locations. Foam swabs - Whenever possible it is better to use lint free swabs such as foam swabs. Note: We strongly recommended that you should shut down the system before you start to clean any single components. Please follow the steps below. 1. Close all application programs. 2.
Slim Medical Panel PC ONYX-MD116 A.3 Scrap Computer Recycling If the computer equipments need the maintenance or are beyond repair, we strongly recommended that you should inform us as soon as possible for the suitable solution. For the computers that are no longer useful or work well, please contact with worldwide distributors for recycling. The worldwide distributors show on the following website: http://www.onyx-healthcare.com.tw/Contact.
Slim Medical Panel PC ONYX-MD116 FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Slim Medical Panel PC ONYX-MD116 RF Exposure Information (SAR) This device meets the government’s requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. The exposure standard employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg.