Slim Medical Panel PC ONYX-1521 ONYX-1521 15.
Slim Medical Panel PC ONYX-1521 Copyright Notice This document is copyrighted, 2011. All rights are reserved. The original manufacturer reserves the right to make improvements to the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of the original manufacturer. Information provided in this manual is intended to be accurate and reliable.
Slim Medical Panel PC ONYX-1521 Acknowledgments z Intel®, CoreTM 2 Duo / Celeron are registered trademarks of Intel® Corporation. z IBM, PC/AT, PS/2 are trademarks of International Business Machines Corporation. z Microsoft® Windows is a registered trademark of Microsoft® Corporation. z RTL is a trademark of Realtek Semi-Conductor Co., Ltd. z C&T is a trademark of Chips and Technologies, Inc. z UMC is a trademark of United Microelectronics Corporation.
Slim Medical Panel PC ONYX-1521 Packing List Before you begin installing your Slim Medical Panel PC, please make sure that the following items have been shipped: ONYX-1521 Slim Medical Panel PC VESA Screws (M4 x 0.7 x 12mm) Utility CD-ROM which contains Drivers and Utilities If any of these items are missing or damaged, you should contact your distributor or sales representative immediately. Headquarters Onyx Healthcare Inc. 2F., No.135, Ln. 235, Baoqiao Rd., Xindian Dist.
Slim Medical Panel PC ONYX-1521 Onyx Healthcare, USA Inc. 2663 Saturn street, Brea, CA 92821, USA Tel : +1-714-996-1800 Fax: +1-714-996-1811 Email: usasales@onyx-healthcare.com Onyx Healthcare EUROPE B.V. Ekkersrijt 4002, 5692 DA Son, The Netherlands Tel : +31-(0)499-462020 Fax: +31-(0)499-462010 Email: eusales@onyx-healthcare.com Onyx Healthcare Technology GmbH An der Trift65d 63303 Dreieich , Germany TEL: +49-(0)61033-7479-00 Fax: +49-(0)61033-7479-49 Email: eusales@onyx-healthcare.
Slim Medical Panel PC ONYX-1521 Room 1318, Metallurgy Building , East Zhongshan Road, Nanjing, China Tel: +86-025-58859841 Fax: +86-025-85088070 Email: Jonwang@onyx-healthcare.com Onyx Healthcare Singapore PTE LTD 57 Genting Lane, #07-00, Singapore 349564 Tel: +65-67498749 Fax +65-67461595 Email: sgsales@onyx-healthcare.
Slim Medical Panel PC ONYX-1521 Safety & Warranty 1. Read these safety instructions carefully. 2. Keep this user's manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Do not use liquid or spray detergents for cleaning. Use a damp cloth. 4. For pluggable equipment, the power outlet must be installed near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6. Put this equipment on a reliable surface during installation.
Slim Medical Panel PC ONYX-1521 service personnel should open the equipment. 14. If any of the following situations arises, get the equipment checked by service personnel: a. The power cord or plug is damaged. b. Liquid has penetrated into the equipment. c. The equipment has been exposed to moisture. d. The equipment does not work well, or you cannot get it to work according to the users manual. e. The equipment has been dropped and damaged. f. The equipment has obvious signs of breakage. 15.
Slim Medical Panel PC ONYX-1521 Classification 1. Degree of production against electric shock: Not classified. TYPE B APPLIED PART for Isolation card function (RS-232) 2. Degree of protection against the ingress of water: IPX0 3. Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. 4. Mode of operation: Continuous 5. Type of protection against electric shock: Class I equipment 6.
Slim Medical Panel PC ONYX-1521 FCC This device complies with Part 15 FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation.
Slim Medical Panel PC ONYX-1521 UL Module Description Onyx-1521 AC modules are developed to suitable for the Classification Mark requirement
Slim Medical Panel PC ONYX-1521 Safety Symbol Description The following safety symbols are the further explanations for your reference. Medical equipment with respect to electric shock, fire and mechanical hazards only in accordance with ANSI/AAMI ES 60601-1: 2005 AND CAN/CSA-C22.2 No. 60601-1:08 Attention, consult ACCOMPANYING DOCUMENTS. Stand-by (Green light) Ground wire Protective Ground wire.
Slim Medical Panel PC ONYX-1521 Below Table for China RoHS Requirements 產品中有毒有害物質或元素名稱及含量 ONYX Panel PC/ Workstation 有毒有害物質或元素 部件名稱 鉛 汞 鎘 六價鉻 多溴聯苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr(VI)) (PBB) (PBDE) × ○ ○ ○ ○ ○ × ○ ○ ○ ○ ○ × ○ ○ ○ ○ ○ × ○ ○ ○ ○ ○ 硬碟 × ○ ○ ○ ○ ○ 液晶模組 × ○ ○ ○ ○ ○ 光碟機 × ○ ○ ○ ○ ○ 觸控模組 × ○ ○ ○ ○ ○ 電源 × ○ ○ ○ ○ ○ 印刷電路板 及其電子元件 外部信號 連接器及線材 外殼 中央處理器 與記憶體 O:表示該有毒有害物質在該部件所有均質材料中的含量均在 SJ/T 11363-2006 標準規定的限量要求以下。 X:表示該有毒有害物質至少在該部件的某一均質材料
Slim Medical Panel PC ONYX-1521 Contents Chapter 1 General Information 1.1 Introduction .................................................................... 1-1 1.2 Features .......................................................................... 1-2 1.3 Specification ................................................................... 1-3 1.4 Dimension ....................................................................... 1-7 Chapter 2 Hardware Installation 2.1 Safety Precautions ......................
Slim Medical Panel PC ONYX-1521 Chapter 1 General Information
Slim Medical Panel PC ONYX-1521 1.1 Introduction The ONYX-1521 is a Slim Medical Panel PC with Intel® Atom D525 1.8GHz Dual Core processor-based computer that is designed to serve as a point of care station. It is a PC-based system with 15.6” true color TFT LCD display, Zero Noise solution; integrated multimedia functions make them the perfect platforms to build comprehensive lifestyle computing applications.
Slim Medical Panel PC ONYX-1521 1.2 Features z 15.6” 1366x768 TFT LCD Display z Easy To Use, Compact, Simple Design z Fanless, Zero Noise z 500 : 1 Contrast Wide View Angle z 300 nits High Brightness z Intel® Atom™ D525 1.8GHz Processor z 5-wire Resistive Touch Screen z 802.11 b/g/n Wireless LAN (Optional) z Weight: 4.
Slim Medical Panel PC ONYX-1521 1.3 Specification Hardware Specifications Display ONYX-1521: 15.6” TFT LCD System Memory 204-pin DDRIII SODIMM x 2, Max. 4GB CPU Board Intel® Atom D525 1.8GHz Dual Core Processor Drive Bay 2.5” Hard Disk Drive/SSD (SATA) Expansion Mini-Card x 2 Button Brightness: “+” / ”-“; Sound: “+” / ”-“; Power SW I/O USB 2.0 x 6 Isolated RS-232 x 2 Isolated Gigabit LAN x 2 Line-out, Mic-in Speaker 3W x 2 Power DC 24V Requirement LCD Specifications Display Type 15.
Slim Medical Panel PC Contrast Ratio 500 : 1 Brightness Control Yes ONYX-1521 Back Light Life Time 50,000 Hrs Note: All ONYX's LCD products are manufactured with High precision technology. However, there are a small number of defective pixels in all LCD panels that are not able to change color. This is a normal occurrence for all LCD displays from all manufacturers and should not be noticeable or objectionable under normal operation.
Slim Medical Panel PC ONYX-1521 Input Voltage 100 ~ 240 Vac, 50/60 Hz, 1.8~0.8A Output Voltages 24VDC-2.91A, 70W MAX MTBF 61320 Calculated Hours (7 years) Environmental Specifications Operating Temperature 0˚C to 40˚C (32˚F ~104˚F) Storage Temperature -20˚C to 60˚C (-4˚F ~140˚F) Storage Humidity 5% to 95%@ 40˚C, non-condensing Vibration 0.5G / 5 ~ 500Hz (Random) / operation Shock 15G peak acceleration (11 msec.
Slim Medical Panel PC ONYX-1521 1.
Slim Medical Panel PC ONYX-1521 ONYX-1521 Unit: mm Chapter1 General Information 1-7
Slim Medical Panel PC ONYX-1521 Chapter 2 Hardware Installation 2.
Slim Medical Panel PC ONYX-1521 Always completely disconnect the power cord from your board whenever you are working on it. Do not make connections while the power is on, because a sudden rush of power can damage sensitive electronic components. Do not make connections while the power is on, because a sudden rush of power can damage sensitive electronic components.
Slim Medical Panel PC ONYX-1521 2.2 A Quick Tour of the ONYX-1521 Before you start to set up the ONYX-1521, take a moment to become familiar with the locations and purposes of the controls, drives, connections and ports, which are illustrated in the figures below. When you place the ONYX-1521 upright on the desktop, its front panel appears as shown in Picture 2-1.
Slim Medical Panel PC ONYX-1521 ONYX-1521 Figure 2.
Slim Medical Panel PC ONYX-1521 2.3 Removing the rear maintenance cover Pull USB cover; Unscrew the attachment screws used to hold the rear maintenance cover and remove rear cover. 2.4 VESA Mounting Holes VESA Screws (M4 x 0.
Slim Medical Panel PC ONYX-1521 Chapter 3 Driver Installation Chapter3 Driver Installation 3-5
Slim Medical Panel PC ONYX-1521 The ONYX-1521 comes with a CD-ROM that contains all drivers and utilities that can help you to install the driver automatically. Insert the driver CD, the driver CD-title will auto start and show the installation guide. If not, please follow the sequence below to install the drivers.
Slim Medical Panel PC 4.1 ONYX-1521 Installation: Insert the ONYX-1521 CD-ROM into the CD-ROM drive. And install the drivers from Step 1 to Step 6 in order. Step 1 – Install Intel® INF Driver 1. Click on the Step 1 – Inf Driver folder and double click on the infinst_autol.exe 2. Follow the instructions that the window shows 3. The system will help you install the driver automatically Step 2 – Install Intel® VGA Driver 1.
Slim Medical Panel PC ONYX-1521 Step 4 –Install Audio Driver 1. Click on the Step 4 –AUDIO driver folder and select the corresponding folder for your operating system and double click on Setup.exe file 2. Follow the instructions that the window shows 3. The system will help you install the driver automatically Step 5 – Install Touch Panel Driver 1. Click on the Touch Driver folder and double click on the setup.exe 2. Follow the instructions that the window shows 3.
Slim Medical Panel PC ONYX-1521 Appendix A Miscellanea Appendix B Miscellanea B-0
Slim Medical Panel PC ONYX-1521 A.1 General Cleaning Tips You may need the following precautions before you begin to clean the computer. When you clean any single part or component for the computer, please read and understand the details below fully. 1. Never spray or squirt the liquids directly onto any computer component. If you need to clean the device, please rub it with a piece of dry cloth. 2. Be cautious of the tiny removable components when you use a vacuum cleaner to absorb the dirt on the floor.
Slim Medical Panel PC ONYX-1521 A.2 Cleaning tools Although many companies have created products to help improve the process of cleaning your computer and peripherals users can also use household items to clean their computers and peripherals. Below is a listing of items you may need or want to use while cleaning your computer or computer peripherals.
Slim Medical Panel PC • ONYX-1521 Cotton swabs - Cotton swaps moistened with rubbing alcohol or water are excellent tools for wiping hard to reach areas in your keyboard, mouse, and other locations. • Foam swabs - Whenever possible it is better to use lint free swabs such as foam swabs. Note: We strongly recommended that you should shut down the system before you start to clean any single components. Please follow the steps below. 1. Close all application programs 2. Close operating software 3.
Slim Medical Panel PC ONYX-1521 A.3 Scrap Computer Recycling If the computer equipments need the maintenance or are beyond repair, we strongly recommended that you should inform us as soon as possible for the suitable solution. For the computers that are no longer useful or work well, please contact with worldwide distributors for recycling. The worldwide distributors show on the following website: http://www.onyx-healthcare.com.tw/Contact.
FCC 15.21 Information to user. Any changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. ISM equipment Note: (a) The interference potential of the device or system (b) Maintenance of the system (c) Simple measures that can be taken by the user to correct interference.