User's Manual

InTemp® CX500 Series Temperature Logger
(CX501, CX502, CX503) Manual
19998-5
InTemp CX500 series loggers measure temperature in transportation monitoring applications.
These Bluetooth® Low Energy-enabled loggers are designed for wireless communication with a
mobile device and can be configured to monitor temperatures in Cold Chain, CRT, and Frozen
shipments. Using the InTemp app, you can easily configure the logger with one of three preset
configurations or you can set up a custom configuration for other applications. The logger has a
built-in alarm to alert you to excursions. Logger reports can be quickly downloaded to your phone
or tablet and automatically uploaded to your InTempConnect account, where you can analyze and
export data as needed. The logger is available in a single-use 15- or 90-day model (CX501 and
CX502) or a multiple-use 365-day model (CX503).
Specifications
Temperature Sensor
CX501 CX502 CX503
Sensor
Range
-10° to 70°C (14° to
158°F)
-30° to 70°C (-22° to
158°F)
-30° to 70°C (-22° to
158°F)
Accuracy
±0.5°C from -10° to
70°C (±0.9°F from 14°
to 158°F)
±0.5°C from -30° to
70°C (±0.9°F from
-22° to 158°F)
±0.5°C from -30° to
70°C (±0.9°F from
-22° to 158°F)
Resolution
0.04°C (0.072°F)
Drift
<0.01°C (0.018°F) per year
Response Time
5 minutes typical to
90% in open air
moving 1 m/s,
unmounted
6 minutes typical to
90% in open air
moving 1 m/s,
unmounted
6 minutes typical to
90% in open air
moving 1 m/s,
unmounted
Logger
Logger Operating Range
-10° to 70°C (-14° to
158°F)
-30° to 70°C (-22° to
158°F)
-30° to 70°C (-22° to
158°F)
Radio Power
1 mW (0 dBm)
Transmission Range
Approximately 30.5 m (100 ft) line-of-sight
Wireless Data Standard
Bluetooth Low Energy (Bluetooth Smart)
Type
Single use Single use Multiple Use
Duration
15 days 90 days Up to 1 year
Shelf Life
Up to 1 year
Logging Rate
1 second to 18 hours
Time Accuracy
±1 minute per month at 25°C (77°F)
Battery
CR2032 (CX501) or CR2450 (CX502 and CX503) 3V lithium, not
replaceable. Battery for CX501 and CX502 lasts for duration specified
when logger is used within the 1-year shelf life. Battery life for the
CX503 model is 1 year, typical with logging interval of 1 minute. Faster
logging intervals, remaining connected with the InTemp app, excessive
downloads, and paging may impact battery life.
Memory
8,800 measurements 14,000 measurements 14,000 measurements
Full Memory
Download Time
Approximately 60 seconds; may take longer the farther the device is
from the logger
Dimensions
6.9 x 4.5 x 1.1 cm (2.71 x 1.76 x 0.42 inches)
Weight
22.1 g (0.78 oz) 25.5 g (0.90 oz) 25.5 g (0.90 oz)
Environmental Rating
IP67
The CE Marking identifies this product as complying with all relevant
directives in the European Union (EU).
See last page
InTemp CX 500 Series
Loggers
Models:
CX501, 15-day logger,
single use
CX502, 90-day logger,
single use
CX503, 365-day logger,
multiple use
Required Items:
InTemp app
Device with iOS and
Bluetooth

Summary of content (4 pages)