A-9010_eng.book 1 ページ 2014年12月25日 木曜日 午前10時48分 A-9010 Integrated Amplifier Instruction Manual Connections ................................ 6 Operations................................. 11 Troubleshooting ........................ 14 To return to the default setting ............14 Thank you for purchasing an Onkyo product. Please read this manual thoroughly before making any connections and plugging in your new Onkyo product.
A-9010_eng.book 2 ページ 2014年12月25日 木曜日 午前10時48分 WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USERSERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
A-9010_eng.book 3 ページ 2014年12月25日 木曜日 午前10時48分 Precautions 1. Recording Copyright—Unless it’s for personal use only, recording copyrighted material is illegal without the permission of the copyright holder. 2. AC Fuse—The AC fuse inside the unit is not userserviceable. If you cannot turn on the unit, contact your Onkyo dealer. 3. Care—Occasionally you should dust the unit all over with a soft cloth. For stubborn stains, use a soft cloth dampened with a weak solution of mild detergent and water.
A-9010_eng.book 4 ページ 2014年12月25日 木曜日 午前10時48分 Precautions For Canadian Models NOTE: CAN ICES-3 B/NMB-3 B For models having a power cord with a polarized plug: CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT.
A-9010_eng.book 5 ページ 2014年12月25日 木曜日 午前10時48分 Introduction Features Remote control sensor Simple circuitry that delivers powerful and faithful sound quality The A-9010 is a model designed to deliver the best performance in sound quality, the most basic element required for a pre-main amplifier. Using our reliable discrete amplifier as a core component, the A-9010 incorporates compact circuitry thanks to its simplified functionality.
A-9010_eng.book 6 ページ 2014年12月25日 木曜日 午前10時48分 Connections GND terminal: Connects the turntable’s ground wire. RI MODE switch (North American and Continental European models): Used to set the link function with the Onkyo equipment with RI terminal. DIGITAL IN COAXIAL (D1)/OPTICAL (D2) jacks (North American and Continental European models): Connects to a reproduction equipment with digital audio output terminal such as CD player, TV, etc.
A-9010_eng.book 7 ページ 2014年12月25日 木曜日 午前10時48分 Connections Connecting CD player, etc., via LINE Using an audio pin cable, connect to one of the terminal of LINE IN 1/2/3/4. Example: Connection with the LINE IN 1 terminal Connecting CD player, etc., via DIGITAL (North American and Continental European models) Connect to either COAXIAL (D1) terminal or OPTICAL (D2) terminal in accordance with the connecting terminal of the reproduction equipment to be used.
A-9010_eng.book 8 ページ 2014年12月25日 木曜日 午前10時48分 Connections Connecting a turntable Connecting Onkyo equipment with RI terminal Using an audio pin cable, connect to the PHONO (MM) terminal. Also, if there is a GND terminal on the turntable, connect with the GND terminal of this unit using a ground wire. Following link functions can be operated by connecting an Onkyo CD player, an RI dock, or a tuner (*) with RI terminal via an RI cable.
A-9010_eng.book 9 ページ 2014年12月25日 木曜日 午前10時48分 Connections ∫ Other connection method ∫ When connecting two or more RI equipment When there are two RI terminals on the equipment, one can be connected to this unit and the other can be connected to other equipment, allowing to link both equipment to this unit. Similarly, it is possible to increase the equipment to be linked. There is no specification for order to connect the equipment.
A-9010_eng.book 10 ページ 2014年12月25日 木曜日 午前10時48分 Connections Connecting speakers Refer to the illustration below to connect the unit and the right and left speakers with the speaker cables. Connect the speaker to be placed on the right hand side to the SPEAKERS terminal (R), and connect the speaker to be placed on the left hand side to the SPEAKERS terminal (L). Important: Connect speakers with 4 h to 16 h impedance. Connecting a speaker with a lower impedance may damage the unit.
A-9010_eng.book 11 ページ 2014年12月25日 木曜日 午前10時48分 Operations (UK models) Í ON/STANDBY button Remote control sensor Volume control Input source LEDs MUTING LED ASB (Auto Standby) LED INPUT selector BASS control TREBLE control BALANCE control DIRECT LED DIRECT button LOUDNESS LED LOUDNESS button LINE 5 jack: Connects to reproducing equipment such as portable audio player via stereo mini-plug (ø 3.5 mm). PHONES jack Turning on the unit Selecting the input source 1. Press the Í ON/STANDBY button.
A-9010_eng.book 12 ページ 2014年12月25日 木曜日 午前10時48分 Operations Adjusting sound quality, etc. Using headphones ∫ DIRECT Turn down the volume, then connect your stereo headphones with a standard plug (ø 6.3 mm, 1/4q) to the PHONES jack. The speakers output no sound while the headphones are connected. Audio is output through shortest path which is advantageous to sound quality without passing the sound quality adjustment circuit (BASS, TREBLE). 1. Press the DIRECT button.
A-9010_eng.book 13 ページ 2014年12月25日 木曜日 午前10時48分 Operations Operating with the remote control Í button: Turn the unit on or put it in standby mode. 0 The power of Onkyo equipment connected via RI will be automatically turned off when the power is turned to standby. INPUT SELECTOR 2/1 buttons: Select an input source of the unit. MUTING button: Mutes the sound. It is displayed as follows when the muting is working. (North American and Continental European models) The input source LED blinks.
A-9010_eng.book 14 ページ 2014年12月25日 木曜日 午前10時48分 Troubleshooting Before starting the procedure Problems may be solved by simply turning the power on/off or disconnecting/connecting the power cord, which is easier than working on the connection, setting and operating procedure. Try the simple measures on both the unit and the connected device.
A-9010_eng.book 15 ページ 2014年12月25日 木曜日 午前10時48分 Specifications Rated output power: 44 watts minimum continuous power per channel, 8 ohm loads, 2 channels driven at 1 kHz, with a maximum total harmonic distortion of 0.08 % (FTC) 70 watts minimum continuous power per channel, 4 ohm loads, 2 channels driven at 1 kHz, with a maximum total harmonic distortion of 0.7 % (FTC) (North American) 2 ch × 44 W at 8 ohms, 1 kHz, 2 ch Driven of 0.08 % (IEC) 2 ch × 70 W at 4 ohms, 1 kHz, 2 ch Driven of 0.
A-9010_eng.book 16 ページ 2014年12月25日 木曜日 午前10時48分 Kitahama Chuo Bldg, 2-2-22 Kitahama, Chuo-ku, OSAKA 541-0041, JAPAN http://www.onkyo.com/ The Americas 18 Park Way, Upper Saddle River, N.J. 07458, U.S.A. For Dealer, Service, Order and all other Business Inquiries: Tel: 201-785-2600 Fax: 201-785-2650 http://www.us.onkyo.com/ For Product Support Team Only: 1-800-229-1687 http://www.us.onkyo.com/ Europe Liegnitzerstrasse 6, 82194 Groebenzell, GERMANY Tel: +49-8142-4401-0 Fax: +49-8142-4208-213 http://www.