User's Manual

Ethernet port (2)
A Port dedicated to connection of a host through a lan cable.
CIDRW head connection port (8)
A port dedicated to connection of a CIDRW head.
Status indicators (3 -6)
Four indicator lamps (RUN, COMM, NORM, ERROR) indicate the
current operating status of the amplifier unit.
24VDC power terminals (1)
Recommended cable : AWG20 - 24
Recommeded connector : Model 1-178288-3 (Tyco Electronics Co.)
Recommended compression ring : Model 175217-3
(Tyco Electronics Co.)
(These connector and compression ring are supplied with model V640-A90.)
Recommended 24 V power supply : Model S8VS-01524(OMRON)
Use the product below as a crimping tool for crimping the compression ring.
Model 919601-1 (Tyco Electronics Co.)
Setup DIP-SW (8)
This switch array allows the operator to assign ID No. to amplifier unit
and define various operating conditions.
DIP-SW settings: factory-setting is all OFF
PRECAUTION FOR SAFE USE
Dimensions
Names and functions
RUN
Remains stably lit as long as the link unit is operating normally.
COMM
Remains lit during the communication with a host or an ID tag.
Lights when the communications with an ID tag are successful.
Lights when the communications with an host or an ID tag are failed.
NORM
ERROR
Be sure to limit the tightening torque for the M4 screws as
1.2 Nm.
material PC+ABS
(Unit: mm)
General specifications
MOUNTING SCREW HOLES
No. Description
IP Address 1
IP Address 2
IP Address 3
IP Address 4
IP Address 5
Reserved
Reserved
Reserved
Test mode
Reserved
Meaning (Content within a box
represents factory-setting)
1
2
3
4
5
6
7
8
9
10
Please turn off this SW.
OFF / ON
Please turn off this SW.
Please turn off this SW.
Supply voltage
Protection rating
Insulation
resistance
Dielectric
Shock resistance
Vibration
resistance
Mounting system
Ambient
humidity
Ambient
temperature
Current consumption
Specification
24 VDC, +10%, -15%
150 mA max
IP20 (IEC 60529)
150m/s
2
, 3 times each in 6 directions
Secured with four M4 screws.
(tightening torque:1.2 Nm)
1000V AC (50/60Hz, for 1 min.)
leak current consumption 5mA max.
(between power supply terminal and frame grounding terminal)
20MΩ min. (100V DC for appliance)
(between power supply terminal and frame grounding terminal)
Operating/ Storage: 35% to 85%
(No freezing, No dew condensation)
Operating: 0 to +40 Storage: -15 to +65
(No freezing, No dew condensation)
10 to 150Hz, 0.20mm double amplitude,
acceleration 15m/s
2
, with 10 sweeps of
8min each in 3 directions
CIDRW head
V640-HS61
Environmental
pollution degree
Degree 2
Over voltage category
Category
Characteristic
V640-HAM11-ETN-V2 V640-HAM11-L-ETN-V2
400 mA max
Applied standards USA / Europe / Japan / Canada
V640-HS62
Please turn off this SW.
(12)
(18.2)
(22.5)
DIP SWITCH
160
175
185
55.5
46
56
80
6.8
6.8
6.8
0.6
4-φ4.5 dia.
(MOUNTING HOLES)
OPERATING
INDICATOR
(11.5)
(32.5)
43
5
(5.
7)
4-M4
175
±0.5
46±0.5
(13)
(18)
(31.95)
(15.8)
24VDC power terminals
MAC Address Label
Ethernet port
* When you set the IP Address by DIP-SW, the IP Address will be fixed as
“192.168.1.XXX”, and the Subnet Mask will be fixed as “255.255.255.0”.
You can set the IP Address and the Subnet Mask as any value by setting
DIP-SW1 - DIP-SW5 to OFF.
1.Ensure safety, be absolutely sure to follow the instructions below:
(1) Never use the product in an environment where combustible or explosive
gas is present.
(2) Please separate from a high-pressure equipment and the power
equipment to secure the safety of the operation and maintenance.
(3)
In the installation, please tighten the screw surely. (Recommended 1.2Nm)
(4) Please do not insert foreign bodies such as water and the wires from the
space of the case.
(5) Please do not dismantle, repair or modify this product.
(6) Please process as industrial waste when you abandon this product.
(7) When you work on wiring and put on and take off cables, CIDRW head,
please perform it after switching off this product.
(8) Provide enough space around this product for ventilation.
(9) Please avoid installing this product near the machinery (a heater, a
transformer, large-capacity resistance) that has high the calorific value.
(10) Please talk to our office by any chance after you cancel use immediately
when you felt abnormality to this product, and having switched it off.
1.About installation site
Do not install this product in the locations subject to the following conditions.
(1)Place where direct sunshine strikes
(2)Place with corroded gas, dust, metallic powder, and salinity
(3)Place with condensation due to rapid temperature fluctuations.
(4)Place with condensation due to high humidity.
(5)Place where vibration and impact more than being provided by
specification are transmitted directly to main body.
(6)Place with spray of water, oil, and chemical medicine.
(7)
The working temperature is within the range stipulated in the specifications.
2.About depository site
(1)
Please follow the save ambient temperature / humidity, and keep this product.
3.About wiring
(1)Use the power supply voltage specified in this cocument.
(2)
Ensure correct polarity when connecting to the +/- power supply terminals.
(3)Do not run high-voltage lines and power lines though the same conduit.
(4)To avoid static-induced failure, wear a wrist band or equivalent means
to release a static charge before touching a terminal or a signal line
within a connector.
(5)When you put on and take off a CIDRW head, please do not add
excessive power to a connector.
(6)Please connect the correct CIDRW head to the amplifier unit.
PRECAUTION FOR CORRECT USE
4.About cleaning
(1)Use alcohol to clean this product.
(2)NEVER use an organic solvent such as thinner, benzene, acetone or
kerosene, as it will attack resin components or case coating.
5.Power and Graound Cables
(1)Use an appropriate ground. An insufficient ground can affect this
product operation or result in damage to this product.
6.About the communication range and time
(1)Do the communication test with Transponder in the installation
environment because the metal, noise and ambient temperature around
CIDRW head damage to the communication range and time.
(2)Install CIDRW head and ID tag in the appropriate distance because the
communication range can change by the difference of ID tag
specifications.
7.About mounting
(1)This product communicates with ID Tags using the 134 kHz frequency
band. Some transceivers, motors, monitoring equipment, and power
supplies (power supply ICs) generate electrical waves (noise) that
interfere with communications with ID Tags, If you are using the
product in the vicinity of any of these devices, check the effect on
communications in advance.
(2)In order to minimize the effects of noise, ground nearby metal bodies
with a grounding resistance not exceeding 100 ohms.
(3)When multiple CIDRW Heads are mounted next to each other,
communications performance could be impaired by mutual
interference. Read and follow the information in this manual on mutual
interference when installing multiple heads.
(4)When mounting CIDRW Heads, tighten the screws tightly.
(Recommended 0.6Nm)
8.Screw Locking Adhesive
(1)Screw locking adhesive (screw lock) may cause deterioration and
cracking of resin parts; do not use it for screws in resin parts or
anywhere where resin washers are used.
9.Communications with the Host Device
(1)Communicate with the host device only after confirming that the
CIDRW Controller has started. Also, unstable signals may occur at the
host interface when the CIDRW Controller is started. When initializing
operation, clear the reception buffer at the host device or take other
suitable methods to clear unwanted signals.
10.Startup precaution
(1)Never turn OFF the power supply while the CIDRW Controller is
starting, including when power is turned ON, when the mode is
changed, or when the CIDRW Controller is being reset. Doing so may
damage the CISRW Controller.
11.About Transponder and RF module made by Texas Instruments Co.
(1)We can’t warrant the specifications of the communication with
Transponder and RF module.
(2) When the RF module is at fault, we can’t analyze the RF module.
12.The characteristics of the V640-HAM11-ETN / V640-HAM11-ETN-V2
(1)It is a circuit, designed to communicate characteristics match, but
because it is intended to carry out the communication with RF module
and the transponder, can not be guaranteed.
You can set the IP Address as “192.168.1.XXX”
XXX = from “001” to “031”
If all switches are OFF, the ROM value will be
set.
(Default : 192.168.1.200 )
©
OMRON Corporation All Rights Reserved.
2015
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.
Manufacturer:
Omron Corporation,
Shiokoji Horikawa, Shimogyo-ku,
Kyoto 600-8530 JAPAN
Ayabe Factory
3-2 Narutani, Nakayama-cho,
Ayabe-shi, Kyoto 623-0105 JAPAN
TRACEABILITY INFORMATION:
Representative in EU:
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
Model
V640-HAM11-ETN-V2
Amplifier Unit
Model
V640-HAM11-L-ETN-V2
Suitability for Use
s
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEE
N DESIGNED TO ADDRESS THE RISKS, AND
THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED
FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
Oct, 2014
D
OMRON Corporation
Industrial Automation Company
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Regional Headquarters

Summary of content (2 pages)