Kanban Reader RFID System Model 4S2VR-V720-KR11 Series Operation Manual Omron Corporation Extensive Area Sales Department Information Product Section March, 2005 Version
Jan. 9, 2004 Jan. 13, 2004 April 1, 2004 Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 1 Chapter 3 Chapter 2 Chapter 4 Chapter 5 April 14, 2004 Chapter 2 June 9, 2004 Chapter 2 June 28, 2004 Chapter 1 Chapter 2 June 30, 2004 July 2, 2004 July 7, 2004 Chapter 3 Chapter 6 P.13 Chapter 2 Chapter 2 July 13, 2004 July 28, 2004 Nov. 10, 2004 Chapter 2 Chapter 2 Chapter 2 1-2 2-1 3-1 4-1 1-2 3-1 2-1 4-5 4-7 5-2 2-4 2-6 1-2 2-1 2-5 3-2 6-4 P.
Introduction Thank you very much for purchasing our Kanban Reader Model 4S2VR-V720-KR11 Series. Model 4S2VR-V720-KR11 Series is a product developed with advanced technology and accumulated experiences of Omron. This Operation Manual includes important information on functions, performance and operating method required for using Model 4S2VR-V720-KR11 Series. In operating Model 4S2VR-V720-KR11 Series, observe the following instructions. • Read and understand this Operation Manual before starting operation.
industrial heating devices: Generally an application for approval is required before installation). Consequently, if such equipment is present nearby, communication with the tag may be affected and the tag may be damaged. In case that this product is used near such equipment, check the effects of such equipment in advance. Observe the following instructions so as to minimize the effects of general noises. • Connect metallic bodies located around this product to Class D grounding (Class 3 grounding).
Contents Chapter 1 Overview of Equipment 1-1 1-2 Features Example of Use of Kanban Reader Chapter 2 Specifications 2-1 2-2 2-3 2-4 2-5 2-6 Part Names and Functions General Specifications Performance Specifications Interface Specifications (RS232C/RS422: To be switched) Dimensional Outline Drawing Cable Connection Diagram Chapter 3 Performance 3-1 3-2 3-3 System Configuration Maximum Communication Range Communication Time Chapter 4 Functions 4-1 4-2 4-3 4-4 4-5 4-6 4-7 Procedure of Communic
Chapter 1 Overview of Equipment 1-1 Features 1. Model 4S2VR-V720-KR11 allows communication with the tag Model 4S2VR-V720-D13P series (Omron) which uses Philips' Model SL2ICS20 (known as "I-CODE II"). 2. For use with a tag in conformity with ISO15693 standard made by other manufacturer, check on communication range and others before use. 3. Since Model 4S2VR-V720-KR11 clearly displays responses, it allows checking on the operation of interfaces with an operator.
1-2 Example of Use of Kanban Reader Kanban reader Model 4S2VR-V720-KR11 is developed for interfacing between man and equipment for a situation in which reading and writing operation is performed mainly with a device like a Kanban held in a hand. Since a laminate tag significantly varies in communication distance, a close examination should be made when this reader is used in fixed installation. 1.
2. When an operator in charge of allocating parts on the assembly line of the plant tries to transfer the prior process information unique to the part to the pick-up Kanban, the operator inserts the pick-up Kanban into the holder. Then the pick-up Kanban shows the operator the presence of the part specified by the pick-up Kanban. When the part Kanban is inserted into other holder, its information is transferred to the pick-up Kanban.
3. Use as a security card or open-close control of gate and door for controlling of entry and exit of people and vehicles to a controlled area In this case the card is used as an ID card not as a Kanban. A Kanban reader is installed for each work section. A person has a Kanban storing personal data and has the data read by the Kanban reader. A computer in a ground-based station controls the presence and destination of persons. Underground tunnel Kanban carried by a worker stores personal ID data.
Chapter 2 Specifications 2-1 Part Names and Functions (Front view) RUN T/R EXT OK (Top view) NG 4S2VR-V720-KR11 1) LED display 2) LED display NG OK OMRON Corporation MADE IN JAPAN 7) Mounting hole 4) CN1 1) 2) 5) CN2 Name LED display LED display (Communication surface) 3) DIP switch 6) CN3 Function OK/NG judgment display Operation display Description NG (Red)/ OK (Green) NG (Red) judgment: No Good OK (Green) judgment: OK EXT (Yellow) external synchronization input T/R (Orange) antenn
4) CN1 Connector for indicator 6P Hoshiden type TCP1366-71-5011 For connection with indicator (option) 1 TXD 2 RXD 3 SG 4 CLK 5 STB 6 KEY (Connector for display) Notes 4 and 5 5) CN2 Connector for host connection 8P Hoshiden type TCP1386-71-5011 RS232C/422 1 TXD 2 RXD RS232C 3 SG 4 SD+ 5 SDRS422 6 RD+ 7 RD8 NC Note 1 6) CN3 I/O connector 8P Hoshiden type TCP1386-71-5011 7) Mounting hole φ4.
2-2 General Specifications Item Supply voltage Consumption current Working ambient temperature Storage ambient temperature Working ambient humidity Communication frequency Weight Radio standards Outline dimensions Installation Specifications 5V±5% (S82K-00705 recommended)* 0.15A -10 - 55°C -25 - +65°C Working ambient humidity: 25%RH - 85%RH (non-condensing) 13.56MHz Approx.
2-3 Performance Specifications Item Communication function I/O function Display function (In planning stage) Specifications Trigger: Communications are made at the time that a command is issued. Auto: When a command is issued anticipating the approach of the tag, communication is executed waiting for the approach of a tag. Continue: When a command is issued, communications with the tag are repeated until a stop command is received. Write-protect function: Write-protect setting on the tag can be made.
2-4 Interface Specifications (RS232C/RS422: To be switched) Compatible connector Communication method Synchro system Communication control method Compatible connector Power supply EXT OK NG RS232C 9600bps 8 bit 1 bit Asynchronous mode ASCII RS422 9600bps 8 bit 1 bit Asynchronous mode ASCII 1 16 Parity (Even number) Max 15 m TCP1386-71-5011 (Hoshiden) Parity (Even number) Max 1000 m TCP1386-71-5011 (Hoshiden) TCP1386-71-5011 (Hoshiden) Two-wire system, half-duplex serial Asynchronous mode TCP138
2-5 Dimensional Outline Drawing (Transmission surface) 30 40 2 NG OK 2 12 15 100 90 13 5 43 RUN T/ R 3 EXT OK 4S2VR- V720- KR11 90 NO:12Z03- 015 100 10 38 OMRON Corporation 10 MADE IN J APAN 3 (50) 30 40 20 20 4 DISP 27 COM POWER 14 25 30 52 15
2-6 Cable Connection Diagram 2-6-1 Power cable Model 4S2VR-V720-KRA10 TCP1386-71-5011 (Hoshiden) 1 +5V Red 2 GND1 Black 3 - 4 EXT Yellow 5 +24V Brown 6 OK Green 7 NG White 8 GND2 Blue Ground the shield to the metal part of the connector.
2-6-3 RC-232C cable (For PLC), Model 4S2VR-V720-KRA41 TCP1386-71-5011 (Hoshiden) 1 TxD 1 FG 2 RxD 2 SD 3 GND1 3 RD 4 SD+ 4 RS 5 SD‐ 5 CS 6 RD+ 6 5V 7 RD‐ 7 DR 8 - 8 ER 9 SG Ground the shield to the metal part of the casing.
Chapter 3 Performance 3-1 System Configuration 1. Example of configuration (Basic configuration) W170 × H85 × D35 DISP Terminal block EXT EXT input DC24V/ AC100V HOST RS232C/RS422 Example of display and power box (In planning stage) Display in 20 digits by 2 lines Built-in reader power and display power Built-in OK/NG buzzer Calendar, clock and log functions are not provided 1) A command response is displayed.
2. Example of configuration (In case of 1 = n connection) W220 × H110 × D45 DISP 10KEY RS422 EXT input DC24V/ AC100V Example of display and power box (In planning stage) Built-in CPU board, built-in calendar clock function, built-in data collection memory Built-in reader power supply and display power supply, built-in OK/NG buzzer 1) 2) 3) 4) The error log of the Kanban reader can be used for maintenance. The same display as shown in the previous section can be presented.
3-2 Maximum Communication Range Reader Model 4S2VRV720-KR11 Series * * Tag Communication range (mm)* Model 4S2VR-V720-D13P01S 5-20 mm, Axial displacement ±20 mm Model 4S2VR-V720-D13P01ST 5-20 mm, Axial displacement ±20 mm Model 4S2VR-V720-D13P30 5-20 mm, Axial displacement ±20 mm Model 4S2VR-V720-D13P02ST 5-15 mm, Axial displacement ±15 mm Model 4S2VR-V720-D13P06ST 5-15 mm, Axial displacement ±15 mm Place the tag in the communication range for communication and do synchronized reading by