User's Manual

A
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
O
N
O
N
FUNCTION
RS-232C MODE
MAIN
SUB
PWR
MODE
RUN
TEST
SET
ERR
COMM
UNIT No.
MS
WS
W NODE W CH
ENTER
RSSI
MCA
ON
ON
OFF
ON
19
21121
x10 x1 x10 x1 x10 x1
24VDC
RS-232C
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
WT30
(1)
(1)
(2)
5 dia.
40
120
(2)
Insert spring
(3) Position the Adapter on the
WT30 and secure with screws.
(2) Pull section A to the right and
lower while compressing the
spring.
(1) Insert the end of section A
into the base of the Adapter.
DIN Rail
Hook the top of the WT30 over the DIN Rail.
Mounting Method
Note: Remove the dust-proof label after mounting.
DIN Rail
Unhook the WT30 from the DIN Rail.
Insert a flat-blade screwdriver or other tool into the lower hook and pull down.
Pull the bottom side forwards.
Removal Method
Attach the adhesive non-slip feet to the bottom of the WT30
and stand the WT30 on a flat surface.
Adhesive non-slip feet
Table-top Mounting
WT30-FT003
Surface Mounting Bracket
WT30-M01-FLK
A
NT1
A
NT
2
Mounting hole
Serial Master Station
Note: Tighten the WT30 mounting
screws using the specified torque of
0.5 to 0.6 N·m
(4.4 to 5.3 in·lb)
.
Note: Tighten the WT30 mounting
screws using the specified torque of
0.5 to 0.6 N·m
(4.4 to 5.3 in·lb)
.
Note: Do not install the product in a metal panel. Doing so will decrease the wireless
performance. To install the product in a panel, use either a Magnet-base
Antenna or Flat Antenna and install the Antenna on the outside of the panel.
Using a DIN Rail Adapter (Installation Tool: WT30-FT001 or WT30-FT002)
Mounting hole dimensions (Unit: mm)
Using a Surface Mounting Bracket
WT30 Terminal model
Type
Specifications (No. of I/O points)
WT30-M01-FLK
Serial Master RS-232C
WT30-SID16 16 DC inputs (NPN/PNP)
WT30-SMD16 I/O Slaves 8 DC inputs (NPN/PNP) + 8 transistor outputs (NPN)
WT30-SMD16-1 8 DC inputs (NPN/PNP) + 8 transistor outputs (PNP)
Note: An Antenna and Mounting Brackets are not included with the FA Wireless SS Terminals.
Available Models
Model Type
WT30-AT001 Magnet-base Antenna
(2 antennas per set)
WT30-AT002 Flat Diversity Antenna
(1 antenna)
WT30-AT003 Pencil Antenna
(2 antennas per set)
Model Type
WT30-FT001 DIN Rail Mounting Bracket (for TH35-7.5)
WT30-FT002 DIN Rail Mounting Bracket (for TH35-15)
WT30-FT003 Surface Mounting Bracket (screw-mounting) (2 brackets per set)
WT30-FT011 Flat Diversity Antenna Mounting Brackets (with magnets)
WT30-CA2M Antenna Extension Cable (1 cable, 2 m)
Model Length
XW2Z-0100U-3 1
m
XW2Z-0200U-3 2
m
XW2Z-0500U-3 5
m
XW2Z-0200U-5 2
m
XW2Z-0500U-5 5
m
Accessories
Antennas
Communications Cables
Other
Specifications
Ratings
Item
WT30-M01-FLK
Serial Master
Power supply
(wireless
communications
power supply)
20 M min. (at 100 VDC) between the
power supply and all I/O and I/O power
supply and between the power supply
and chassis
Dielectric strength
Power
supply
WT30-SID16/SMD16/
SMD16-1 I/O Slaves
20.4 to 26.4 VDC
25% to 85% (with no condensation or icing)
No corrosive gases
25 to 65 °C (with no condensation or icing)
IP20
Screwless terminal block
(Phoenix Contact FFKDS/V1-5.08 or equivalent)
Ambient operating humidity
Ambient environment
Storage temperature
Degree of protection
Terminal
construction
Rated voltage
Allowable
voltage range
24 VDC
20.4 to 26.4 VDC
Power
consumption
Error output/
output power
supply (for
output circuits)
Rated voltage 24 VDC
Allowable
voltage
range
---
---
20 M min. (at 100 VDC)
between the power supply
and chassis
1,500 VAC for 1 min between the
power supply and all I/O and I/O
power supply and between the
power supply and chassis
1,500 VAC for 1 min
between power supply
and chassis
---
10 to 55°C (with no
condensation or icing)
(with the Terminal
mounted with the dust-
proof label facing up)
3.5 W max.
Wireless Interface Specifications
One stage using I/O slave for the serial master configuration.
100 kbps
64 max.
Number of I/O Slaves
connected
WT30 FA Wireless SS Terminal
Instruction Sheet
Notification Sheet
Package Contents
Terminal labels (slaves only)
Adhesive non-slip feet (master only)
Installation
Using a DIN Rail
Ambient operating
temperature
Conforms to JIS C0041: 300 m/s
2
3 times each in X, Y, and Z
Shock resistance
Vibration resistance
JIS C0040
Frequency: 10 to 55 Hz; Amplitude of 0.35 mm or acceleration of
50 m/s
2
, whichever is smaller (DIN Rail mounting: single-amplitude
of 0.1 mm or acceleration of 15 m/s
2
)
10 sweeps of 8 min each (i.e., 80 min in total) in X, Y, Z directions
Insulation resistance
Serial
330 g max.
10 mW/MHz
10 sets max. (recommended)
Number of stations per
area
Relay functions
Baud rate between
wireless stations
Weight
Conformity to Safety Standards
Always use a Class 2 power supply to conform to UL standards.
CRC-CCITT (16 bits)
Error detection method
IEC61000-4-4. 1 kV (power supply line)
Specifications Item
Wave type Spread Spectrum (direct sequence; SS-DS)
SimplexCommunication method
2,402.2 to 2,480.2 MHz
66 channels (based on switching)
Frequency band
Number of channels
Transmitter output
power
Number of simultaneously ON I/O
points
10 max.: 10 to 55 ˚C
16 max.: 10 to 50 ˚C
(with no condensation or icing)
(with the Terminal mounted with the
dust-proof label facing up)
Application
For personal
computer
For PLC
Note: Use the WT30-FT003 Surface Mounting Bracket when installing the WT30 in
environments subject to vibration.
Precautions for Correct Use
Always heed these precautions to prevent faulty operation, malfunction, or adverse affect on the product's
performance and functionality.
1) Communications performance will vary according to the operating environment. Always check operations
before using the product.
2) Do not install the antenna in a location surrounded by metal, such as in a control panel.
3) Install the antenna so that it is as far away as possible from and not parallel to electric wires or metal
plates.
4) Do not use this product in areas exposed to extremely high humidity, near televisions or radios, near
motors or drills that emit sparks, near strong magnets, or near fluorescent lights.
5) Make sure that the terminal blocks, communications cables (RS-232C cables), and other items with
locking devices are properly locked into place.
6) Do not pull or bend cables with force.
7) Do not change the mode selection switch during operation.
Safety Precautions
Definition of Precautionary Information
WARNING
Indicates a potentially hazardous situation which, if not avoided, will result
in minor or moderate injury, or may result in serious injury or death.
Additionally there may be significant property damage.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury or in property damage.
Suitability for Use
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combi-
nation of the products in the customer's application or use of the product.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with
which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITH-
IN THE OVERALL EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
1618797-0A
T2
FA Wireless SS Terminals
Model WT30
ENG
Instruction Sheet
Thank you for purchasing this OMRON product. Read this instruction sheet and
thoroughly familiarize yourself with the functions and characteristics of the product
before using it. This product is designed for use by qualified personnel with
knowledge of electrical systems. Keep this instruction sheet for future reference.
For detailed application procedures, refer to the WT30 Operation Manual (Cat. No. N138).
Noise immunity
Use a DC power line less than 3 m to conform to EN standards. If a power line of 3 m or longer is required,
extend the length at the Switching Power Supply’s primary side (i.e., the AC power line).
Approx. 1 million writes
EEPROM write life
Wireless standards have been met for the following countries. The product cannot be used in any other
countries.
Austria, Belgium, China (see note), Cyprus, Czech, Denmark, Estonia, Finland, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Japan, Latvia, Lithuania, Luxembourg, Malta, Netherlands,
Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland, UK, USA
Note: Channel 51 cannot be used in China. Use channels 2 to 34 or channels 52 to 83.
Use is also prohibited in aircraft or near airports.
Caution
To ensure that the WLAN transmitter complies with current FCC regulations limiting both maximum RF
output power and human exposure to radio frequency radiation, a separation distance of at least 20 cm
must be maintained between the unit's antenna and the body of the user and any nearby persons at all
times and in all applications and uses.
FCC RF Radiation Exposure Statement
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
D-sub, 9-pin (female) Inch
screws (OMRON XM2F-
0910-132 or equivalent)
Precautions for Safe Use
Precautionary Information
WARNING
Using the FA Wireless SS Terminal near a pacemaker or other medical device may affect the
operation of the medical device, possibly resulting in serious injury. Never use the FA Wireless
SS Terminal near pacemakers or other medical devices.
Do not use this product for real-time control.
Design the system to ensure safety in the event of temporary interruptions in communications due to
interference with the electromagnetic waves used for communications caused by the ambient
environment and application methods.
Always provide protective circuits in the network. Without protective circuits, malfunctions may possibly
result in accidents that cause serious injury or significant property damage. Provide double or triple
safety measures in external control circuits, such as emergency stop circuits, interlock circuits, or limit
circuits, to ensure safety in the system if an abnormality occurs due to malfunction of the product or
another external factor affecting the product's operation.
CAUTION
Make sure that the direction and polarity (+/-) are correct when connecting terminal blocks and connec-
tors. Turning ON the power to I/O circuits with the I/O cables connected in reverse, may result in a
blown output fuse.
Do not apply a voltage or connect a load to the outputs that exceeds the maximum switching capacity.
Do not allow pieces of metal, wire clippings, or fine metallic shavings or filings from installation to
enter the product. Doing so may occasionally result in minor electric shock, fire, or malfunctions.
Do not attempt to disassemble, repair, or modify the product, or touch the internal parts of the prod-
uct. Doing so may occasionally result in minor electric shock, fire, or malfunctions. In Japan, disas-
sembly and modification is also prohibited under Japan's Radio Law and may be punishable by law.
Leave the protective label in place when wiring the product. After completing wiring, always remove
the protective label to enable proper heat dissipation. Fire may occasionally result if this precaution is
not observed.
Be sure to observe the following precautions to ensure safe use of the product.
1) Transport the product in the box in which the product was packaged, making sure the product is not
subjected to excessive vibrations or shock, or dropped.
2) Store the product within the specified environment. Allow the product to warm up to room temperature for
at least 3 hours after it has been stored at 10 °C or lower.
3) Use the product within the specified temperature and humidity ranges.
4) Do not use the product in the following locations.
Locations subject to extreme temperature changes resulting in condensation
Locations subject to static electricity, excessive noise, or electric fields
Locations where the product may come into contact with water, oil, or chemicals
Locations where corrosive gases or flammable gases are present
Locations where large amounts of dust or dirt are present
Locations subject to spatters, iron chips, or filings
5) Do not install the product outdoors (outside a control panel).
6) Use tape, cord, or other means to hold the product while adjusting the installation position to prevent the
product from damage due to falling.
7) Do not install the product in areas where it will be subject to excessive external force, or in walkways.
8) Tighten the mounting screws to the specified torque of 0.5 to 0.6 N·m (4.4 to 5.3 in·lb).
9) Provide sufficient space around the product for heat dissipation.
10) Do not install the product in walkways or locations subject to traffic when installing the product outside a
control panel.
11) Do not reverse the power supply connection or connect the product to an AC power supply.
12) Use the correct power supply voltage.
13) Use AWG22 to AWG16 to connect wires for post terminals. For solid or standard wires, however, use
AWG20 to AWG16 (0.52 to 1.5 mm
2
). The length of exposed wire is 10 mm.
14) Do not apply voltage to the inputs exceeding the rated voltage range.
15) Use communications cables (RS-232C cables) with a length of 15 m maximum and a load of 2,500 pF
maximum.
16) Do not lay communications cables (RS-232C cables) and antenna cables near other high-voltage cables
or power lines.
17) Use the specified cables for communications cables (RS-232C cables).
18) Be sure to perform communications tests to confirm operation after wiring before using the product.
19) Always set the product after it is installed or replaced. Set the product correctly according to the manual,
and be sure to perform the tests provided with the product (e.g., communications tests) before operating
it.
20) When operating the product without checking serial numbers, check whether an existing system is
present, and design the system carefully to prevent radio interference.
21) Do not apply excess vibrations or shock to this product. Do not drop this product.
22) Make sure that wiring and switch settings are correct before starting operations.
23) Other wireless devices operating within the same frequency band may interfere with this product or be
adversely affected by this product. Therefore, be sure to perform the tests provided with the product
(e.g., installation tests) before operating it.
24) Make sure that the antenna is not disconnected during operation.
25) Do not use this product near other devices that may malfunction due to the electromagnetic waves
emitted by this product.
26) Turn OFF the power supply before performing any wiring or replacing devices.
27) Do not touch the product with wet hands.
28) Dispose of the product as industrial waste.
FCC WARNING
Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
* Reorient or relocate the receiving antenna.
* Increase the separation between the equipment and receiver.
* Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
* Consult the dealer or an experienced radio/TV technician for help.
Dansk
[Danish]
Deutsch
[German]
Eesti
[Estonian]
English
Español
[Spanish]
Français
[French]
Italiano
[Italian]
Latviski
[Latvian]
Nederlands
[Dutch]
Malti
[Maltese]
Magyar
[Hungarian]
Polski
[Polish]
Português
[Portuguese]
Slovensko
[Slovenian]
Slovensky
[Slovak]
Suomi
[Finnish]
Svenska
[Swedish]
Íslenska
[Icelandic]
Norsk
[Norwegian]
Undertegnede Omron Corporation erklærer herved, at følgende udstyr WT30
overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF.
Hiermit erklärt Omron Corporation, dass sich das Gerät WT30 in Übereinstimmung
mit
den g
rundlegenden Anforderungen und den übrigen einschlägigen
Bestimmungen der Richtlinie 1999/5/EG befindet.
Käesolevaga kinnitab Omron Corporation seadme WT30 vastavust direktiivi
1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele
sätetele.
Hereby, Omron Corporation, declares that this WT30 is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC.
Por medio de la presente Omron Corporation declara que el WT30 cumple con los
requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de
la Directiva 1999/5/CE.
Par la présente Omron Corporation déclare que l’appareil WT30 est conforme aux
exigences essentielles et aux autres dispositions pertinentes de la directive
1999/5/CE.
Con la presente Omron Corporation dichiara che questo WT30 è conforme ai
requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva
1999/5/CE.
Šiuo Omron Corporation deklaruoja, kad šis WT30 atitinka esminius reikalavimus ir
kitas 1999/5/EB Direktyvos nuostatas.
Hierbij verklaart Omron Corporation dat het toestel WT30 in overeenstemming is
met de essentiële eisen en de andere relevante bepalingen van richtlijn
1999/5/EG.
Alulírott, Omron Corporation nyilatkozom, hogy a WT30 megfelel a vonatkozó
alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.
Omron Corporation declara que este WT30 está conforme com os requisitos
essenciais e outras disposições da Directiva 1999/5/CE.
Omron Corporation vakuuttaa täten että WT30 tyyppinen laite on direktiivin
1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen
mukainen.
Härmed intygar Omron Corporation att denna WT30 står l överensstämmelse med
de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av
direktiv 1999/5/EG.
Hér með lýsir Omron Corporation yfir því að WT30 er í samræmi við grunnkröfur og
aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC.
Omron Corporation erklærer herved at utstyret WT30 er i samsvar med de
grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF.
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ Omron Corporation ∆ΗΛΩΝΕΙ ΟΤΙ WT30 ΣΥΜΜΟΡΦΩΝΕΤΑΙ
ΠΡΟΣ ΤΙΣ ΟΥΣΙΩ∆ΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ∆ΙΑΤΑΞΕΙΣ ΤΗΣ
Ο∆ΗΓΙΑΣ 1999/5/EK.
Ελληνικη
[Greek]
Lietuviu
[Lithuanian]
Cesky
[Czech]
Omron Corporation tímto prohlašuje, ze tento WT30 je ve shode se základními
pozadavky a dalšími príslušnými ustanoveními smernice 1999/5/ES.
Ar šo Omron Corporation deklare, ka WT30 atbilst Direkt vas 1999/5/EK
butiskajam pr
as bam un citiem ar to
saist tajiem noteikumiem.
Hawnhekk, Omron Corporation, jiddikjara li dan WT30 jikkonforma mal-htigijiet
essenzjali u ma provvedimenti ohrajn relevanti li hemm fid-Dirrettiva 1999/5/EC.
Niniejszym Omron Corporation oswiadcza, ze WT30 jest zgodny z zasadniczymi
wymogami oraz pozostalymi stosownymi postanowieniami Dyrektywy 1999/5/EC.
Omron Corporation izjavlja, da je ta WT30 v skladu z bistvenimi zahtevami in
ostalimi relevantnimi dolocili direktive 1999/5/ES.
Omron Corporation týmto vyhlasuje, ze WT30 splna základné poziadavky a všetky
príslušné ustanovenia Smernice 1999/5/ES.

Summary of content (1 pages)