CENTURY SPOT PR-2002 This product manual contains important information about the safe installation and use of this projector. Please read and follow these instructions carefully and keep this manual in a safe place for future reference. PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, 511430 China h t t p : / / w w w . p r- l i g h t i n g .
INDEX SECTION PAGE SAFE USAGE OF THE PROJECTOR 3 STRUCTURE 4 FITTING THE LAMP 4 POWER SUPPLY – MAINS 4 OPERATION 5 STAND-ALONE MODE 6 XLR CONNECTORS AND TERMINATOR 6 MASTER/SLAVE MODE 7 CONTROLLER MODE - DMX 512 OPERATION 8 MAINTENANCE 9 KEEPING THE PROJECTOR CLEAN 9 TROUBLESHOOTING 9 TECHNICAL DATA 10 ELECTRICAL DIAGRAM 11 COMPONENT ORDER CODES 12 Please note that as part of our ongoing commitment to continuous product development, specifications are subject to change withou
SAFE USAGE OF THE PROJECTOR The following points are important for safety as well as for the smooth installation and performance of the unit. When unpacking and before disposing of the package check there is no transportation damage before using the projector. Should there be any damage caused by transportation, consult your dealer and do not use the apparatus. Keep the package well for your possible future transportation. The projector is intended for outdoor use and is splash-proof, IP44.
STRUCTURE FITTING THE LAMP Caution: For the safety reason, remove the sponge between the colour filters before the 1st application of luminaire. Position the projector-head facing the sky and lock it via locking knob. Remove the projector-head cover by loosening the 4 retaining clips. Open the dichroic-colour-filter bracket by undoing the 2 M6 knurled-screws. Insert the lamp in the lamp-holder, and ensure PST (pumping stem tip off) on the lamp is at a right angle (90°) to the beam path.
OPERATION When the power is switched on, the apparatus automatically starts to run the programmes of selftest. After finishing these, the apparatus is ready for the following operation. Remove the cover of the control panel. You will see the panel as shown in the figure below. The right red LED flashes means there is a DMX signal receiving. Press the button RESET to reset the DMX start address and functions, and the left green LED will flash one time. TO SET THE DMX START ADDRESS See the panel above.
CODE 1 2 3 4 5 OPTION Y Y Y FUNCTION Auto-program enable Master/Slave mode enable Choose 1 of 7 built-in program Set time between scenes Reset enable STAND-ALONE MODE Without connecting the controller, when enable the function 1, the apparatus will run in standalone mode. In this mode, you can set the DMX start address to any value.
DMX TERMINATOR In the Controller mode or Master/Slave mode, the DMX output has to be connected with a DMX terminator at the last fixture in the chain. This prevents electrical noise from disturbing and corrupting the DMX control signals. The DMX terminator is simply an XLR connector with a 120Ω (ohm) resistor connected across pins 2 and 3, which is then plugged into the output socket on the last projector in the chain. The connections are illustrated below.
CONTROLLER MODE – DMX 512 OPERATION Century Spot adopts international standard DMX 512 protocol. You may control many luminaires via controller. When in controller mode, the function code 1 and 2 of all luminaires should be set to “n”, and each apparatus should have specific address to receive the signal from the controller. Century Spot has 6 channels. So, in controller mode, the address of 1st luminaire is 001; 2nd, 007; 3rd, 013; 4th, 019; etc.
MAINTENANCE If the lamp becomes damaged or deformed in any way it must be replaced. If the light from the lamp appears dim this would normally indicate that it is reaching the end of its life and it should be changed at once, old lamps run to the extremity of their life may explode. If the projector does not function, check the fuse in the projector base. It should only be replaced by fuse of the same specified value 16A/380V (fast blow, ceramic).
TECHNICAL DATA Power supply: 220/230V AC 50/60Hz Power consumption: 2800W Lamp: OSRAM HMI 2500W/SE, single end Colour temperature: 6000°K Manufacturers Rated Lamp life: 500 Hours Protocol: Standard DMX 512 Running mode: Stand-alone, Master/Slave, and DMX Controller DMX channels: 6 channels Colours: 3 basic colours, CYM 256 colours continuous mixing, white, blackout Beam coverage: 12°- 35° Tilt angle: Adjustable from 15°to 90° Net weight: 75 kg Others: Linear dimming from 0-100%, thermal
ELECTRICAL DIAGRAM 11/14 Century Spot manual_Last Revision_en.
COMPONENT ORDER CODES NAME TRANSFORMER IGNITOR BALLAST RELAY FILTER THERMOSTAT 1 THERMOSTAT 2 FAN (4 pcs) FAN LAMP CAPACITOR (4 pcs) MOTOR MOTOR IC1 U1~U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 PART NO.
/14 Century Spot manual_Last Revision_en.
PR LIGHTING LTD. No. 571, Yingbin Road, Dashi, Panyu, Guangzhou, China Post-Code: 511430 TEL: +86-20-8478 1888 FAX: +86-20-8478 6023 P/N: 320040047 Last Revision: 02:08:2004 14/14 Century Spot manual_Last Revision_en.