INSTRUCTIONS FOR THE USER INSTRUCTIONS FOR THE INSTALLATION AND USE OF BUILT-IN HOT PLATES OCG63XB/OCG63FXB OCG75XB/OCG75FXB OCG90XB/OCG90FXB
IMPORTANT SAFETY INSTRUCTIONS We invite you to read this instruction booklet carefully, before installing and using the equipment. It is very important that you keep this booklet together with the equipment for any future consultation. If this equipment should be sold or transferred to another person, make sure that the new user receives the booklet, so that they can learn how to operate the appliance and read the corresponding notice. This is a Class 3 appliance.
INSTRUCTIONS FOR THE USER It is necessary that all the operations regarding the installation, adjustment and adaptation to the type of gas available are carried out by authorised personnel, in conformity with the regulations in force. The specific instructions are described in the booklet section intended for the installer.
INSTRUCTIONS FOR THE USER 1 2 3 4 Burner Flame safeguard sensor (OCG63FXB, OCG75FXB and OCG90FXB ONLY) Injector Ignition spark plug If you have a problem with the cooktop, check the table below. You may be able to solve the problem and this will save you from paying for a service call. You will have to pay for a service call even in the warranty period if the problem is one listed below FAULT POSSIBLE CAUSES Burner will not light even though the sparkler is working.
INSTRUCTIONS FOR THE USER CLEANING Before any operation, disconnect the appliance from the electrical supply. Don’t use a steam cleaner for the cleaning the hob. It is advisable to clean the appliance when it is cold. Enamelled parts The enamelled parts must be washed with a sponge and soapy water or with a light detergent. Do not use abrasive or corrosive products. Do not leave substances, such as lemon or tomato juice, salt water, vinegar, coffee and milk on the enamelled surfaces for a long time.
INSTRUCTIONS FOR THE INSTALLER Adjacent walls, cupboards and protection for combustible materials. Ensure that the appliance is installed in accordance with clauses 6.2.5 and 6.10.1.1 of AS/ NZS 5601.1, or clauses 6.9.1 and 6.9.5 of AS/NZS 5601.2 with regard to clearances to combustible surfaces and materials, and clearances to rangehoods and exhaust fans. Clearance of 200mm from the periphery of burners to vertical combustible surfaces is required.
INSTRUCTIONS FOR THE INSTALLER OPERATION ON N.G / S.N.G. Gas Connection This appliance is supplied for use with Natural Gas. However, it can be converted for use with LPG. Refer to LP conversion chapter. Supply pipe sizing The total hourly gas consumption for the appliance is shown on the data label. The required supply pressure (i.e. at inlet to appliance regulator) for each gas type is shown on the data label, and given in page "TECHNICAL CHARACTERISTIC TABLES".
INSTRUCTIONS FOR THE INSTALLER Electrical connection The appliance is supplied with a standard 10 Amp service cord terminated by a 3-pin plug for connection to a standard household socket. The electrical supply is required to power the electronic ignition system. NOTE: It will be necessary for servicing purposes to disconnect the electrical power supply. The power point should therefore be accessible after the appliance is installed, as specified in the local wiring regulations.
OFF MAXIMUM MINIMUM 1 2 3 4 5 6 F F 7 9 8 8/A 9/A 9
Electrical Supply Cord Gas Connection 207 105 510 MODEL:OCG63XB/ OCG63FXB 5 3 8 Gas Connection Depth of cooktop casing from benchtop surface : 44 mm 590 Electrical Supply Cord 270 183 2 510 1 MODEL:OCG75XB/ OCG75FXB 4 2 Depth of cooktop casing from benchtop surface : 44 mm 3 Gas Connection 750 8 Electrical Supply Cord 295 280 2 510 1 4 2 MODEL:OCG90XB/ OCG90FXB Depth of cooktop casing from benchtop surface : 44 mm 3 8 890 1 Rapid burner 2 Semi-rapid burner 3 Auxiliary burner 4
APPLIANCE DETAILS BURNERS N° 1 GAS DESCRIPTION RAPID NORMAL PRESSURE INJECTOR DIAMETER KPa 1/100 mm Universal LPG 2.75 85 TAPE BY PASS DIAMETE R / 40 NOMINAL HEAT INPUT (MJ/h) 9.6 Natural 1.00 155 Adjust. 11.5 Universal LPG 2.75 65 31 5.6 Natural 1.00 110 Adjust. 6.3 Universal LPG 2.75 52 27 3.4 Natural 1.00 80 Adjust. 3.4 2 SEMI-RAPID 3 AUXILIARY 4 TRIPLE CROWN Universal LPG 2.75 95 60 12.0 Natural 1.00 160 Adjust. 13.
INSTRUCTIONS FOR USING THE MINI TRIVET The mini-trivet included with this cooktop is to be used for cooking vessels of diameter 120mm or smaller Incorrect fitment Correct fitment Examples of positioning of mini-trivet MODEL: OCG63XB/OCG63FXB MODEL:OCG75XB/OCG75FXB MODEL:OCG90XB/OCG90FXB 12