Installation Procedure for the Groundhog? G-4 Permanent Traffic Analyzer PLACE YOUR GLOVES ON AT THIS TIME FOR ALL STEPS INVOLVE! LTE NG BOND. vl & STEP 10 Pour one quart of Bond epoxy PART STEP 11 Pour one quart of Bond epoxy PART A into a disposable bucket. 8 into the disposable bucket. Li STEP 13 immediately pour the epoxy mixture into the hole.
Installation Procedure for the Groundhog? G-4 Permanent Traffic Analyzer i STEP 15 Push the Groundhog canister down into the hole. The canister should be no more than 1/8" below the surface of the road. DO NOT EXTEND ABOVE THE ROAD, if necessary, add additional epoxy so that the perimeter around the canister has no sink marks. STEP 17 Once some of the epoxy squeezes out around the Groundhog case, take a putty knife and spread the epoxy around the outer edge of the canister.
Installation Procedure for the Groundhog® G-4 Permanent Traffic Analyzer TIP: Center your body weight by placing a knee STEP 21 Plug the battery lead wire into the cir in the center of the lid tool. This will help main coot board. This will turn the unit ON, and pertain leverage as the lid is removed, pare it for data collection. CAUTION! Failure to locate and align the traffic flow Indicator with the direction of traffic WILL affect the sensor's data integrity.
installation Procedure for the Groundhog® G-4 Permanent Traffic Analyzer TIP: Place the lid on top of the threads and turn in the same direction as if you were removing the lid. This wilt eventually produce a ‘click’. Stop when you hear this click and then proceed to tighten in the opposite direction. This wiki ensure a good seat for tightening. LAST STEP Nu-Metrics strongly recommends that the installer place a bead of silicon around the tid into the small space between the lid and the can sister.
Troubleshooting Guide for Permanent Count Stations TROUBLESHOOTING PERMANENT COUNT STATION Tools Required: (3 Analog telephone 1d Voltmeter / Digital Multi meter THIS CHECKLIST APPLIES TO A SITE POWERED BY AC POWER! 1. CHECK POWER STATUS OF THE CABINET ADp 3 Verify the site has AC electrical power. ENp 1 Verify the circuit breaker has not tripped. Upm id Reset the circuit breaker, switch OFF then back ON.
Troubleshooting Guide for Permanent Count Stations LIMITED WARRANTY GENERAL COVERAGE: This Nu-Metrics system, but not items or computer products covered by other manufacturers warranty, Is warranted to the owner for a period of one year from the date of original purchase against defects in manufacture or workmanship. This limited warranty is given by Nu-Metrics and not by the distributor or representative from whom the equipment was purchased.
Troubleshooting Guide for Permanent Count Stations refund the purchase price of a disk damaged by accident, abuse, or misapplication. Any implied warranties on the disks, including implied warranties of merchant ability and fitness for a particular purpose, are limited in duration to 90 days from the date of delivery.