Shenzhen Wuxiang Testing (Group) Co., Ltd. Report No. WUX202107133461UL APPLICATION FOR TEST REPORT UL 62368 On Behalf of Prepared For : ORICO Technologies Co., Ltd. Address : 1903-1904.14A, Zhonghaixin Innovation Industrial park, no.12, Gan Lee Sixth Road, Gankeng Community, Jihua Street, Shenzhen, China Product Name : Surge Protector with USB Charger Model : CK-6A3U-US, CK-3A3U-US Trade Name : Manufacturer : ORICO Technologies Co., Ltd. Address : 1903-1904.
Page 2 of 60 Report No. WUX202107133461UL TEST REPORT UL 62368-1 Audio/video, information and communication technology equipment Part 1: Safety requirements Report Number...................................: WUX202107133461UL Date of issue....................................... : July 19, 2021 Total number of pages..................... : 61 pages Tested by (name, function, signature) .......................................... : Approved by (name, function, signature) ................................
Page 3 of 60 Report No. WUX202107133461UL List of Attachments (including a total number of pages in each attachment): - Pages 1 to 53 for IEC 62368 TRF - Appendix 1 (6 pages): U.S.A. NATIONAL DIFFERENCES against IEC Standards: UL 62368-1: 2014 - Appendix 2 (6 pages): Product photo Summary of testing: The sample(s) tested complies with the requirements of IEC 62368-1:2014 (Second Edition) and UL 62368-1: 2014 Max. ambient temperature is considered as 25°C.
Page 4 of 60 Report No. WUX202107133461UL Test item particulars: Product group ........................................................ : end product Classification of use by.........................................
Page 5 of 60 Report No. WUX202107133461UL Possible test case verdicts: - test case does not apply to the test object.... : N/A - test object does meet the requirement........... : P (Pass) - test object does not meet the requirement.... : F (Fail) Testing: Date of receipt of test item................................... : July 13, 2021 Date (s) of performance of tests..........................
Page 6 of 60 Report No. WUX202107133461UL OVERVIEW OF ENERGY SOURCES AND SAFEGUARDS Clause Possible Hazard 5 Electrically-caused injury Class and Energy Source (e.g. ES3: Primary circuit) Body Part (e.g. Ordinary) Safeguards B S R -- -- 1, Plastic enclosure. ES3: Primary circuit connect to Ordinary person AC mains 6 Electrically-caused fire Class and Energy Source (e.g. PS2: 100 Watt circuit) Material part (e.g.
Page 7 of 60 Report No. WUX202107133461UL ENERGY SOURCE DIAGRAM Optional. Manufacturers are to provide the energy sources diagram identify declared energy sources and identifying the demarcations are between power sources. Recommend diagram be provided included in power supply and multipart systems. Insert diagram below. Example diagram designs are; Block diagrams; image(s) with layered data; mechanical drawings ❎ ES TRF No.
Page 8 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark 4 General Requirements P 4.1.1 Acceptance of materials, components and subassemblies P 4.1.2 Use of components Components which are certified to IEC or UL standards are used correctly within their ratings. Verdict P Components not covered by IEC or UL standards are tested under the conditions present in the equipment 4.1.
Page 9 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict which is comprised of air. The following parts prevent the displacement of the air by a body part or a conductive part after the mechanical strength test specified in Annex T. The plastic enclosure. 4.4.3.10 Accessibility, glass, safeguard effectiveness No class 3 energy sources become accessible to an ordinary person or an instructed person. P No glass used.
Page 10 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict 4.8.5 Compliance N/A 30N force test with test probe N/A 20N force test with test hook N/A 4.9 Likelihood of fire or shock due to entry of conductive object P 4.10 Component requirements P 4.10.1 Disconnect Device (See Annex L) N/A 4.10.2 Switches and relays (See Annex G) N/A 5 ELECTRICALLY-CAUSED INJURY P 5.2 Classification and limits of electrical energy sources P 5.2.
Page 11 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark 5.4 Insulation materials and requirements P 5.4.1.2 Properties of insulating material P 5.4.1.3 Material is non-hygroscopic P 5.4.1.4 Maximum operating temperature for insulating materials........................................................................ : 5.4.1.5 Pollution degrees..........................................................: 5.4.1.5.
Page 12 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark 5.4.2.4 Determining the adequacy of a clearance using an electric strength test .................................................... : Clearance determined by required withstand voltage was complied 5.4.2.5 Multiplication factors for clearances and test voltages Only 2000m above sea level, ........................................................................................
Page 13 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark 5.4.5.2 Voltage surge test Test with impulse generator as table D.1 circuit 3 with output of 10KV applied between power plug of power strip and it’s output. 5.4.5.3 Insulation resistance (M)......................................... : >500 M Electric strength test.....................................................: (See appended table 5.4.9) 5.4.
Page 14 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test 5.4.12.1 General requirements 5.4.12.2 Electric strength of an insulating liquid.....................: (See appended table 5.4.9) N/A 5.4.12.3 Compatibility of an insulating liquid...........................: (See appended table 5.4.9) N/A 5.4.12.4 Container for insulating liquid.................................... : 5.5 Components as safeguards 5.5.1 General 5.5.2 Capacitors and RC units 5.5.2.
Page 15 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict 5.6.5 Terminals for protective conductors N/A 5.6.5.1 Terminal size for connecting protective earthing conductors (mm).......................................................... : N/A Terminal size for connecting protective bonding conductors (mm)...........................................................: N/A 5.6.5.2 Corrosion P 5.6.6 Resistance of the protective bonding system P 5.6.
Page 16 of 60 Report No. WUX202107133461UL UL 62368-1 Clause 5.8 Requirement + Test Result - Remark Verdict a) Equipment connected to earthed external circuits, current (mA)................................................... : N/A b) Equipment connected to unearthed external circuits, current (mA)................................................... : N/A Backfeed safeguard in battery backed up supplies N/A Mains terminal ES........................................................
Page 17 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark 6 ELECTRICALLY- CAUSED FIRE P 6.2 Classification of PS and PIS P 6.2.2 Power source circuit classifications............................: 6.2.3 Classification of potential ignition sources 6.2.3.1 Arcing PIS .................................................................... : (See appended table 6.2.3.1) P 6.2.3.2 Resistive PIS ................................................................
Page 18 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict 6.4.6 Control of fire spread in PS3 circuits P 6.4.7 Separation of combustible materials from a PIS P 6.4.7.2 Separation by distance N/A 6.4.7.3 Separation by a fire barrier N/A 6.4.8 Fire enclosures and fire barriers 6.4.8.2 Fire enclosure and fire barrier material properties Overall enclosure is considered as fire enclosure 6.4.8.2.
Page 19 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark 7 INJURY CAUSED BY HAZARDOUS SUBSTANCES N/A 7.2 Reduction of exposure to hazardous substances N/A 7.3 Ozone exposure N/A 7.4 Use of personal safeguards or personal protective equipment (PPE) N/A Personal safeguards and instructions...................... : 7.5 Verdict Use of instructional safeguards and instructions N/A Instructional safeguard (ISO 7010)...........................: 7.
Page 20 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict Space between end point and nearest fixed mechanical part (mm).................................................. : N/A Endurance requirements N/A Mechanical system subjected to 100 000 cycles of operation N/A - Mechanical function check and visual inspection N/A - Cable assembly..........................................................: N/A 8.5.4.
Page 21 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict Test 3 Nominal diameter (mm) and applied torque (Nm)............................................................................... : N/A 8.8 Handles strength N/A 8.8.1 General N/A 8.8.2 Handle strength test N/A Number of handles.......................................................: Force applied (N)..........................................................: 8.
Page 22 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test 9.3.2 Test method and compliance P 9.4 Safeguards against thermal energy sources P 9.5 Requirements for safeguards N/A 9.5.1 Equipment safeguard N/A 9.5.2 Instructional safeguard................................................ : N/A 10 RADIATION N/A 10.2 Radiation energy source classification N/A 10.2.1 General classification N/A 10.3 Result - Remark Verdict Lasers..................................
Page 23 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test 10.6.1 General N/A 10.6.2 Classification N/A Acoustic output LAeq,T, dB(A)....................................... : N/A Unweighted RMS output voltage (mV)...................... : N/A Digital output signal (dBFS)........................................ : N/A 10.6.3 Requirements for dose-based systems N/A 10.6.3.1 General requirements N/A 10.6.3.2 Dose-based warning and automatic decrease N/A 10.6.3.
Page 24 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict B.3.1 General P B.3.2 Covering of ventilation openings P Instructional safeguard............................................... : P B.3.3 DC mains polarity test No D.C. mains used N/A B.3.4 Setting of voltage selector No such selector N/A B.3.5 Maximum load at output terminals B.3.6 Reverse battery polarity No battery N/A B.3.
Page 25 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test C.1.3 Test method N/A C.2 UV light conditioning test N/A C.2.1 Test apparatus............................................................. : N/A C.2.2 Mounting of test samples N/A C.2.3 Carbon-arc light-exposure test N/A C.2.4 Xenon-arc light-exposure test N/A D TEST GENERATORS N/A D.1 Impulse test generators N/A D.2 Antenna interface test generator N/A D.
Page 26 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test F.3.2.2 Model identification .....................................................: P F.3.3 Equipment rating markings P F.3.3.1 Equipment with direct connection to mains Direct connection to AC mains F.3.3.2 Equipment without direct connection to mains See clause F.3.3.1 F.3.3.3 Nature of the supply voltage...................................... : The symbol, IEC60417-5032 (2002-10), used for a.c. F.3.3.
Page 27 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark F.3.10 Test for permanence of markings Conducted by rubbing the marking by hand without appreciable force for 15 s with a piece of cloth soaked with water and at a different place or on a different sample for 15 s with a piece of cloth soaked with the petroleum spirit specified the reagent grade hexane with a minimum of 85 % n-hexane.
Page 28 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test F.5 Instructional safeguards P G COMPONENTS P G.1 Switches P G.1.1 General P G.1.2 Ratings, endurance, spacing, maximum load P G.1.3 Test method and compliance P G.2 Relays N/A G.2.1 Requirements N/A G.2.2 Overload test N/A G.2.3 Relay controlling connectors supplying power to other equipment N/A G.2.4 Test method and compliance N/A G.3 Protective devices G.3.
Page 29 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict G.5.1 Wire insulation in wound components P G.5.1.2 Protection against mechanical stress P G.5.2 Endurance test N/A G.5.2.1 General test requirements N/A G.5.2.2 Heat run test N/A Test time (days per cycle).......................................... : Test temperature (C)................................................. : G.5.2.
Page 30 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark G.5.4.3 Running overload test N/A G.5.4.4.2 Locked-rotor overload test N/A Test duration (days) ................................................... : Verdict G.5.4.5 Running overload test for DC motors N/A G.5.4.5.2 Tested in the unit N/A G.5.4.5.3 Alternative method N/A G.5.4.6 Locked-rotor overload test for DC motors N/A G.5.4.6.2 Tested in the unit N/A Maximum Temperature .......
Page 31 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test G.7.5.2 Test method and compliance Result - Remark Verdict N/A Overall diameter or minor overall dimension, D (mm)...............................................................................: Radius of curvature after test (mm).......................... : G.7.6 Supply wiring space P G.7.6.1 General requirements N/A G.7.6.2 Stranded wire N/A G.7.6.2.1 Requirements N/A G.7.6.2.
Page 32 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict Type test voltage Vini,a................................................. : Routine test voltage, Vini, b.......................................... : G.13 Printed boards P G.13.1 General requirements P G.13.2 Uncoated printed boards P G.13.3 Coated printed boards N/A G.13.4 Insulation between conductors on the same inner surface N/A G.13.
Page 33 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict Largest capacitance and smallest resistance for ICX tested by itself for 10000 cycles test.................: G.16.3 Capacitor discharge test.............................................: N/A H CRITERIA FOR TELEPHONE RINGING SIGNALS N/A H.1 General N/A H.2 Method A N/A H.3 Method B N/A H.3.1 Ringing signal N/A H.3.1.1 Frequency (Hz) .............................................
Page 34 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test K.7 Interlock circuit isolation N/A K.7.1 Separation distance for contact gaps & interlock circuit elements N/A In circuit connected to mains, separation distance for contact gaps (mm)................................................. : N/A In circuit isolated from mains, separation distance for contact gaps (mm).................................................
Page 35 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark M.3.3 Compliance (See appended table M.3) M.4 Additional safeguards for equipment containing a portable secondary lithium battery N/A M.4.1 General N/A M.4.2 Charging safeguards N/A M.4.2.1 Requirements N/A M.4.2.2 Compliance...................................................................: M.4.3 Fire enclosure...............................................................: N/A M.4.
Page 36 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test M.7.4 Marking..........................................................................: N/A M.8 Protection against internal ignition from external spark sources of batteries with aqueous electrolyte N/A M.8.1 General N/A M.8.2 Test method N/A M.8.2.1 General M.8.2.2 Estimation of hypothetical volume VZ (m /s)........... : M.8.2.3 Correction factors........................................................
Page 37 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict P.3.3 Spillage safeguards N/A P.3.4 Compliance N/A P.4 Metallized coatings and adhesives securing parts N/A P.4.1 General N/A P.4.2 Tests N/A Conditioning, TC (°C)................................................... : Duration (weeks)..........................................................: Q CIRCUITS INTENDED FOR INTERCONNECTION WITH BUILDING WIRING P Q.
Page 38 of 60 Report No. WUX202107133461UL UL 62368-1 Clause S.2 Requirement + Test Result - Remark Verdict Test flame according to IEC 60695-11-5 with conditions as set out N/A - Material not consumed completely N/A - Material extinguishes within 30s N/A - No burning of layer or wrapping tissue N/A Flammability test for fire enclosure and fire barrier integrity N/A Samples, material........................................................ : Wall thickness (mm)...........................
Page 39 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict T.11 Test for telescoping or rod antennas N/A Torque value (Nm) ...................................................... : N/A U MECHANICAL STRENGTH OF CATHODE RAY TUBES (CRT) AND PROTECTION AGAINST THE EFFECTS OF IMPLOSION N/A U.1 General N/A Instructional safeguard : N/A U.2 Test method and compliance for non-intrinsically protected CRTs N/A U.
Page 40 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Y.4.3 Tensile strength and elongation tests N/A Alternative test methods............................................. : N/A Y.4.4 Compression test N/A Y.4.5 Oil resistance N/A Y.4.6 Securing means Y.5 Protection of equipment within an outdoor enclosure N/A Y.5.1 General N/A Y.5.2 Protection from moisture N/A Relevant tests of IEC 60529 or Y.5.3....................... : N/A Y.5.
Page 41 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test 5.2 TABLE: Classification of electrical energy sources Supply Voltage Location (e.g. circuit designation) 275Vac Primary circuits 275Vac T1 Pin 6-7 Result - Remark Verdict N/A Test conditions Parameters U (V) I (mA) 275Vrms -- SS -- Abnormal -- -- -- -- /Single faultSC/OC -- -- -- -- 41.6Vpk -- SS -- -- SS -- 0 -- SS -- Normal 5.12Vdc 0.07 SS -- Abnormal 5.
Page 42 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict 5.4.2, 5.4.3 TABLE: Minimum Clearances/Creepage distance P Clearance (cl) and creepage distance (cr) at/of/between: Up (V) Urms (V) Freq (Hz) Required cl (mm) cl (mm) Required cr (mm) cr (mm) Different polarity of AC mains before fuse 350 250 60 1.5 3,3 -- 2.4 3,3 Two poles of fuse 350 250 60 1.5 3.6 -- 2.5 3.
Page 43 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test 5.4.9 TABLE: Electric strength tests Test voltage applied between: Result - Remark Verdict P Voltage shape (Surge, Impulse, AC, DC, etc.
Page 44 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test 5.5.2.2 TABLE: Stored discharge on capacitors Location Result - Remark Verdict N/A Supply voltage (V) Operating and fault condition 1) Switch position Measured voltage (Vpk) ES Class Supplementary information: X-capacitors installed for testing: bleeding resistor rating: ICX: 1) Normal operating condition (e.g., normal operation, or open fuse), SC= short circuit, OC= open circuit 5.6.
Page 45 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test 6.2.2 TABLE: Power source circuit classifications Location Operating and fault condition For load circuits All primary circuit connected to AC mains Output with 5Vdc Normal Result - Remark Verdict P Voltage (V) Current (A) Max. Power1) (W) Time (S) PS class -- -- -- -- PS3 4,88V 3.92 17.
Page 46 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test 8.5.5 TABLE: High pressure lamp Lamp manufacturer Result - Remark Verdict N/A Lamp type Explosion method Longest axis of Particle found glass particle beyond 1 m (mm) Yes / No Supplementary information: 9.6 TABLE: Temperature measurements for wireless power transmitters N/A Supply voltage (V)...............................................: Max. transmit power of transmitter (W)...........
Page 47 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark 5.4.1.4, TABLE: Temperature measurements Verdict P 9.3, B.1.5, B.2.6 Supply voltage (V)...............................................: Ambient temperature during test Tamb (C)...... : 90V(60Hz) 275 (50Hz) 24.7 Maximum measured temperature T of part/at: -- -- 24.9 Allowed Tmax (C) T (C) T1 coil 66.1 64.4 -- -- 110 T1 core 60.3 59.2 -- -- 110 Plastic enclosure inside near T1 48.
Page 48 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test B.2.5 TABLE: Input test Result - Remark Verdict P U (V) Hz I (A) I rated (A) P (W) P rated (W) Fuse No I fuse (A) Condition/status 125 60 15.1 -- 1875 -- -- -- Max. load 90 50 0.15 -- 16.42 -- -- -- 90 60 0.15 -- 16.41 -- -- -- Only load the USB output 100 50 0.13 -- 16.33 -- -- -- 100 60 0.13 -- 16.34 -- -- -- 240 50 0.09 -- 16.30 -- -- -- 240 60 0.09 -- 16.
Page 49 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark Verdict immediately, No hazarded. C3 SC 275 10mins F1 0 The EUT shut down, recoverable, No hazarded U1 Pin 3-5 SC 275 1min F1 0 The fuse opened immediately, No hazarded. USB + to - SC 275 30mins F1 0 The EUT shut down, recoverable, No hazarded Supplementary information: M.
Page 50 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test manufacturer/type and fault condition Result - Remark Charging voltage (V) Charging current (A) Verdict Temp. (oC) Supplementary information: Abbreviation: SC= short circuit; OC= open circuit; MSCV= maximum specified charging voltage; MSCC= maximum specified charging current; HSCT= highest specified charging temperature; LSCT= lowest specified charging temperature Q.
Page 51 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark T.2, T.3, T.4, T.5 TABLE: Steady force test P (N) Test Duration (s) -- 250 5 No damaged, No hazards Min. 1.5 -- 250 5 No damaged, No hazards Plastic Min. 1.5 -- 250 5 No damaged, No hazards Plastic Min. 1.5 -- 10 5 No damaged, No hazards Material Thickness (mm) Probe Plastic enclosure top Plastic Min. 1.
Page 52 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Enclosure Plastic Result - Remark Min. 1.5 70 7 Verdict No energy source exceed class 1 can be accessed -Supplementary information: X TABLE: Alternative method for determining minimum clearances distances Clearance distanced between: Supplementary information: TRF No.
Page 53 of 60 Report No. WUX202107133461UL UL 62368-1 Clause Requirement + Test Result - Remark 4.1.2 TABLE: Critical components information Verdict P Object / part No. Manufacturer/ trademark Type / model Technical data Standard Mark(s) of conformity1) -- -- -- -- -- -- Supplementary information: 1) Provided evidence ensures the agreed level of compliance.. Description line content is optional. Main line description needs to clearly detail the component used for testing. 2) TRF No.
Page 54 of 60 Report No. WUX202107133461UL Appendix 1 ATTACHMENT TO TEST REPORT IEC 62368-1 2TH ED. U.S.A. NATIONAL DIFFERENCES AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT – PART 1: SAFETY REQUIREMENTS Differences according to..................: CSA/UL 62368-1:2014 Attachment Form No........................ : US&CA_ND_IEC623681B Attachment Originator......................: UL(US) Master Attachment............................
Page 55 of 60 Report No. WUX202107133461UL 6.5.1 PS3 wiring outside a fire enclosure complies with single fault testing in B.4, or be current limited per one of the permitted methods. P Annex F Output terminals provided for supply of other equipment, except mains, supply are marked with a maximum rating or references to which equipment it is permitted to be connected. P (F.3.3.8) Annex G (G.7.
Page 56 of 60 Report No. WUX202107133461UL Consumer products designed or intended primarily for children 12 years of age or younger are subject to additional requirements in accordance with U.S. & Canadian Regulations. N/A Baby monitors additionally comply with ASTM F2951, Consumer Safety Specification for Baby Monitors. N/A Annex DVA (5.6.3) For Pluggable Equipment Type A, the protection in the installation is assumed to be 20A. P Annex DVA (6.
Page 57 of 60 Report No. WUX202107133461UL Annex DVA (G.4.3) Where a fuse is used to provide Class 2 or Class 3 current limiting, it is not operatoraccessible unless it is non- interchangeable. N/A Annex DVA (G.5.3) Power distribution transformers distributing power at 100 volts or more, and rated 10 kVA or more, require special transformer overcurrent protection. N/A Annex DVA (G.5.
Page 58 of 60 Report No. WUX202107133461UL Annex DVH Equipment for permanent connection to the mains supply is subjected to additional requirements. N/A Annex DVH (DVH.1) Wiring methods (terminals, leads, etc.) used for the connection of the equipment to the mains are in accordance with the NEC/CEC. N/A Annex DVH (DVH.3.2) Terminals for permanent wiring, including protective earthing terminals, are suitable for U.S.
Page 59 of 60 Appendix 2 Product photos Product view_1 Product view_2 TRF No. IEC62368_1C Report No.
Page 60 of 60 Product view_3 Over view_4 ***END OF THE REPORT*** TRF No. IEC62368_1C Report No.