MiCard V3 Installation Manual (Full Install Guide)
Versioning Versioning WP Name Version Author(s) 1.0 Thomas Lemmer Revision date Reviewer(s) MiCard V3 - Installation Manual Knowledge Base File Name MiCard_V3_Full_Installation_Guide_EN_V1.0.pdf Technologies concerned uniFLOW Login Manager/MomClient (Secure/Public Printing Applet) Short Summary This manual describes the features, the installation, and the configuration of the MiCard V3 Reader in detail. MiCard is a registered trademark of NT-ware Systemprogrammierung GmbH.
Disclaimer All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems - without the written permission of NT-ware Systemprogrammierung GmbH. Company and product names mentioned herein are registered or unregistered trademarks of their respective companies.
Symbols Text Styles Text that appears in this style is used for screen text that appears in the uniFLOW user interface and on user interface controls. Text that appears in this style is used for User entries on screen, text that the user actually has to type in. Text that appears in this style is used for hyperlinks to an external web page, or internal links to other pages of this manual. Text that appears in this style is used for code examples: XML code, variables or regular expressions.
MiCard V3 Installation Manual (Full Install Guide) Contents Contents 1 MiCard V3 contactless card reader ............................................................. 2 1.1 Scope of supply ............................................................................................................. 2 1.2 Requirements ............................................................................................................... 2 1.3 FCC and IC Compliance Note ........................................
MiCard V3 Installation Manual (Full Install Guide) 1 MiCard V3 contactless card reader MiCard V3 provides an easy to use, easy to install and cost effective solution for user identification with a contactless card alongside your Canon iR and Canon imageRUNNER ADVANCE. With MiCard V3 users can be identified by simply waving their card over the reader. After identification the device unlocks and you are able to make your copies or pick up your secure print jobs.
MiCard V3 Installation Manual (Full Install Guide) Rated Voltage: 5V USB: 1.1 (Full-Speed) or 2.0 (Hi-Speed Ambient Temperature: 0 … +50 °C Canon Device: uniFLOW: LPS (23 … +122 °F) Has to be a Canon MEAP enabled MFP USB Application Interface board of the respective Canon iR or Canon imageRUNNER ADVANCE uniFLOW Login Manager/MomClient (Secure/Public Printing Applet) V2.1.0 onwards (V2.4.0 recommended) uniFLOW OM / uniFLOW and / or RPS V4.0.
MiCard V3 Installation Manual (Full Install Guide) 1.3 FCC and IC Compliance Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
MiCard V3 Installation Manual (Full Install Guide) Note that the extended configuration of the MiCard V3 is only possible with MEAP applets from V2.4.0 onwards. 1.6 To connect the MiCard V3 reader to the MFP, simply plug the USB cable into the USB Host Connection of the MFP and into the USB socket of the card reader (Please be aware that the USB connections may be arranged in a different order depending on the model of the copier).
MiCard V3 Installation Manual (Full Install Guide) This is the control panel of an imageRUNNER ADVANCE C5051i. Pull the control panel forward, towards you. Unscrew the screw on the right side of the reader cover. To open the cover, pull it towards you and lift it up.
MiCard V3 Installation Manual (Full Install Guide) Detach the surface cover of the reader cover to mount the hook-and-loop fastener. Attach the hook-and-loop fastener as can be seen in these pictures. Attach the surface cover to the reader cover and screw in the cover screws. Assemble the MiCard V3 as can be seen in the next picture.
MiCard V3 Installation Manual (Full Install Guide) Plug in the USB cable (USB sign facing the back of the device, i.e. not towards you) and close the cover. Screw in the cover screw. Slide the control panel back into its original position. When all covers are closed, you can switch on the device. The machine and the card reader will boot up. During the boot up process of the card reader, the red LED of the MiCard V3 should flash.
MiCard V3 Installation Manual (Full Install Guide) 1.7 On other imageRUNNER ADVANCE models like the C9070PRO for example, or the C7065, open the toner cartridge cover and unscrew the two card reader cover screws as shown in the picture. Proceed as described above. LED Status The MiCard V3 reader is equipped with 3 status LEDs: green (left), yellow (middle) and red (right). The table below shows the status information given by the respective LED.
MiCard V3 Installation Manual (Full Install Guide) If a Facility Code has been detected as invalid. 2 3 x fast Configuration The MiCard device works without any additional configuration, however, some "advanced" options are available. When using uniFLOW OM V3.1.1 or higher you can see the connected MiCard readers on the MEAP/miniMIND Status tab (or List view tab for uniFLOW V5.x) of the main menu Connections. By clicking on in the ID-Device column, a new window will open showing you the advanced options.
MiCard V3 Installation Manual (Full Install Guide) Click on the ID-Device column to open a configuration pop-up. This will look like the screenshot below: The terms used and the possible settings of the configuration window are as follows: Connected ID Module Shows the ID Module connected, e.g. MiCard / miniMIND. Last Read ID Shows the last ID read by a card swipe. Conversion Result Shows the result of the last read ID when the configured code conversions are applied.
MiCard V3 Installation Manual (Full Install Guide) next to the name of the selected code conversion in the drop down list. If the result is empty "()", this code conversion can’t be applied in the actual step (cf. screenshot above). After a code conversion step [N] has been saved by clicking the Save button the configuration page will be allowed to specify code conversion step [N+1] as shown in the screenshot above.
MiCard V3 Installation Manual (Full Install Guide) Once the upload is complete, the MiCard (V3) is automatically rebooted with the new Firmware. A device restart is not necessary. If the update fails, the MiCard will start in a "Bootloader" mode that allows updating the Firmware again, but has no card reading functionality. Note, with a failed Firmware update, it can take a considerable amount of time before the reader is once again visible in uniFLOW. 2.1 Upgrading from SSP to uniFLOM OM V4.
MiCard V3 Installation Manual (Full Install Guide) 3.1 Global MiCard V3 Configuration With MiCard V3, it is possible to configure the MiCard contactless card reader right from the uniFLOW server. To do so, go to Connections / MEAP & miniMIND (uniFLOW V5.x: Connections/Agents/Terminals/MiCard V3, then open the Global MiCard V3 Config. tab Multi. You can configure the MiCard V3 for a number of different contactless card types: Multi for Legic cards 3.1.
MiCard V3 Installation Manual (Full Install Guide) 3.1.2 Configuration - Multi On this page options for the contactless card reader Multi can be configured. The contactless card reader Multi offers four different card technologies, ISO 14443A, ISO 15693, Legic Prime and Inside contactless. However, the MiCard V3 only allows one ID or card technology to be read at the same time. This makes sense, as only one ID should be transmitted to the uniFLOW Server or RPS in order to identify the user.
MiCard V3 Installation Manual (Full Install Guide) Search String Enter a string to search for, to find the sector containing the user ID. Auto Logoff when Card gone -factory default- (No) No Yes - If this parameter is set to Yes, the contactless card must lie on the card reader as long as the user is using the device. When the card is removed from the reader, the user is logged off automatically. Data Length This value defines the length of the data that has to be read from the Legic card.
MiCard V3 Installation Manual (Full Install Guide) By clicking on this second MiCard V3 configuration. icon a window opens in which you can set up a specific The device specific parameters are the same as for the Global MiCard V3 Configuration (on page 14). You can enable your device specific settings by changing the parameter Use Specific MiCard V3 Config to Yes. The device specific settings will become active by clicking the Save button.
MiCard V3 Installation Manual (Full Install Guide) Index Index B L Beep Status ........................................................... 9 LED Status .............................................................9 C M Configuration ......................................................10 MiCard V3 Configuration on the uniFLOW Server ........................................................................... 13 Configuration - General ......................................
© NT-ware 2009-2012