User's Manual

1
WS15Z5-1 WALL MOUNT SWITCH
The GoControl
family of Z-Wave
®
certifi ed wireless Lighting Products (smart LED
xtures, bulbs, switches, dimmers, outlets and plug-in modules) Control Products
(thermostats, irrigation controller and garage door controller) and Sensors (fl ood, leak,
alert sounder, motion sensor and door/window sensor) bring a new level of intelligent
wireless Home Automation capability to commercial and residential environments.
The Z-Wave wireless protocol is an international wireless standard for remote home
automation, security and other applications. This product can be included and
operated in any Z-Wave network with other Z-Wave certifi ed devices from other
manufacturers and/or other applications. All non-battery operated nodes within the
network will act as repeaters regardless of vendor to increase reliability of the network.
The WS15Z5-1 Wall Mount Switch allows remote ON/OFF control of loads
connected to the switch, and is easily wired in place of a standard wall switch.
GoControl Z-Wave products are easy to install, are Z-Wave certifi ed, and allow
dealers to create an integrated wireless network with nearly limitless expansion
and interoperability with security, energy management, home entertainment,
appliances, and more.
DANGER! SHOCK HAZARD. Read and understand these instructions before
installing. This device is intended for installation in accordance with the National
Electric code and local regulations in the United States, or the Canadian Electrical
Code and local regulations in Canada. It is recommended that a qualifi ed electrician
perform this installation. Make sure the load controlled by the switch does not
exceed 1800 watts. For indoor use only. Retain instructions for future use.
Z-WAVE PLUS FEATURES
The WS15Z5-1 contains a Z-Wave 500 Series Module that supports Z-Wave Plus
®
features. A Z-Wave certifi ed portable or stationary Controller can communicate with
the Z-Wave 500 Series Module.
Depending on the capability of the Controller or gateway software, the following
operations can be performed with the WS15Z5-1. Refer to the Controller or gateway
manual for details.
Turn the load ON and OFF.
Add or Remove the WS15Z5-1.
Assign the WS15Z5-1 to a specific Group/Scene and/or to include the load as part of
ALL ON or ALL OFF system commands.
Over-the-air firmware update by the gateway or static Controller.
Lifeline function which automatically notifies the associated modules and the network
that a manually reset device is no longer in the network, thus, the corresponding
association becomes invalid.
INSTALLATION
Wire this switch in place of a current wall switch according to the diagram above.
When used, WS15Z5-1’s are required to be wired to the same line (or neutral)
which is also wired to the load being controlled, and not wired to any other neutral.
If multiple neutrals are tied together in one box, separate the neutrals to preserve
the integrity of the WS15Z5-1 circuit.
CAUTION! Do not wire unit “live” (with power on the circuit).
Adding to a network:
Refer to your Controller operating instructions to add this switch under the command
of the Wireless Controller.
1. With your Controller in Discovery or Add Mode, tap the switch. The LED will blink
slowly when in ADD Mode.
2. You should see an indication on your Controller that the “device was added” to
the network and the LED will stop blinking.
3. The device will appear in the list of Switches. It should display as a switch.
If the Controller/Gateway shows the addition failed, repeat Steps 1-3.
NOTE: If you have trouble adding the WS15Z5-1 to a group it may be that
the Home ID and Node ID were not cleared from it after testing. You must fi rst
“RESET UNIT” to remove it from the network. Although adding it to a group
includes it in the network, removing it from a group does not remove it from
the network. If removed from a group, it functions as a repeater (only). “RESET
UNIT” removes it completely from the network.
To Reset Unit (If Required):
In the event that your primary Controller is lost or otherwise inoperable, to reset the
WS15Z5-1 and clear all network information, follow these steps:
1. Tap the top of the switch fi ve (5) times.
2. Press and hold the bottom of the switch for 15 seconds. The LED will increasingly
blink faster to indicate that a Reset is taking place.
Removing from a network:
The WS15Z5-1 can be removed from the network by the Controller/Gateway. Refer
to the Controller operating instructions for details.
1. Set the Controller into Removal Mode and follow its instruction to delete the
WS15Z5-1 from the Controller.
2. Remove the switch by tapping the paddle 2 times. The LED will begin blinking
slowly for 10 seconds indicating that it has been removed.
3. You should see an indication on your Controller that the “device was removed”
from the network.
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,WS15Z5-1; P/N: 10007259 A; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 8.500” x 11.000”; TOLERANCE ± .125”; SCALE: 1-1;
WS15Z5-1
Z-Wave Radio Frequency (RF) Controlled, 120 VAC
Scene and NWI Capable, Wall Mount Switch, Series 500
NEUTRAL
120 VAC
PUSH ON
WHITE
LINE
BLACK
PUSH OFF
STATUS LED
GREEN GROUND
TAP TOP OR BOTTOM
OF SWITCH PADDLE
TO CONFIGURE
SCORED TAB WILL
BREAK FLUSH WITH
EDGE OF PLASTIC
BLUE
LOAD
15 AMPS
MAXIMUM
WS15Z5-1 AND THE LOAD
MUST SHARE THE SAME
PROPRIETARY NEUTRAL
Shown with supplied
decorative trim plate
NOTE: This unit must be added to the Network only where it will be permanently installed. The proper operation of this node in the