User Instructions

Copyright © 2013 Linear Corporation 235512 X8
GB00Z-1
WIRELESS
GLASS BREAK
DETECTOR
Installation Instructions
1. PRODUCT DESCRIPTION
The Model GB00Z-1 is a battery powered glass break detector with built-in Z-Wave
®
interoperable two-way RF mesh networking technology designed for use with Lowe’s
Iris
®
Smart Home Hub. This device is used for perimeter protection.
The GB00Z-1 can send fi ve different signal types: fault, restore, low battery, status,
and tamper. The Iris system hub must be paired with the glass break detector before
system testing and operation. Refer to the Lowe’s Iris system Web site for details on
pairing and testing the detector.
In a typical installation, the detector is mounted on a wall or ceiling within 15 feet of
the protected glass window(s). The unit uses dual-stage digital audio processing to
detect the sound of breaking glass in a 360° area around the device. If the unit detects
breaking glass, a fault signal is sent to the system followed by a restore signal.
Periodically, the unit sends a status signal to update the system. If the battery tests
low, a low battery signal is included with any transmission. The glass break detector
is powered from two 3-Volt CR123A lithium batteries (included).
An internal switch senses if the detector is removed from its base. Removing the
detector will send a tamper signal to the system.
Three screws and screw anchors are provided for mounting the detector.
2. FEATURES
3. INSTALLING OR CHANGING BATTERIES 4. PAIRING OR UN-PAIRING THE DETECTOR WITH THE HUB 5. MOUNTING THE DETECTOR
6. DETECTOR TESTING 7. SPECIFICATIONS
Operating Temperature: 32° to 120° F (0° to 49° C)
Operating Relative Humidity: 5 to 95%, non-condensing
Operating Frequency: 908.42 MHz
Battery Type: Two 3-Volt CR123A Lithium Batteries
Sensor Type: Single microphone,
dual-stage (thud & crash)
The minimum size for all glass types is 11” x 11” (28 cm x 28 cm) square. Glass must
be framed, in a wall of the room or mounted in a barrier of 36” (91 cm) minimum width.
GLASS TYPE MINIMUM TO MAXIMUM THICKNESS
PLATE 1/8” TO 1/4” (3.2 mm TO 6.4 mm)
TEMPERED 1/8” TO 1/4” (3.2 mm TO 6.4 mm)
SEALED, INSULATING 1/8” TO 1/4” (3.2 mm TO 6.4 mm)
Z-Wave is a registered trademark of Sigma Designs Inc. and/or its subsidiaries.
8. LINEAR LIMITED RETAIL WARRANTY
Linear LLC (the Company) warrants to the original purchaser that products delivered hereunder will be free of defects in materials and
workmanship for a period of one (1) year from the date of purchase.
The Company within said period shall at its option, either repair or replace free of charge, any product or part thereof found, upon the
Company’s inspection, to be so defective, and will return the repaired or replaced product to the purchaser at Company’s expense.
All products returned for warranty service require a Return Product Authorization Number (RPA#). For warranty service, shipping
instructions, and an RPA#, contact Linear Technical Services at 1-800-421-1587. Devices must be sent to the Company at owner’s expense
and be accompanied with statement of defect and proof of purchase.
This warranty is conditioned on the following:
1. The Company must be notified within one year of purchase and have been given the opportunity of inspection by return of any alleged
defective product free and clear of all liens and encumbrances to the Company or its distributor; and
2. The product must not have been abused, misused or improperly maintained and/or repaired during such period; and
3. Such defect has not been caused by corrosion or exposure to other than ordinary wear and tear.
THE COMPANY MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER INCLUDING ANY WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
The Company’s maximum liability hereunder is limited to the purchased price of the product. In no event shall the Company be liable for any
consequential, indirect, incidental or special damages of any nature arising from the sale or use of the product, whether based in contract,
tort, strict liability or otherwise.
Note: Some states do not allow limitations on incidental or consequential damages or how long an implied warranty lasts, so that the above
limitations may not fully apply. This warranty gives specific legal rights and you may also have other rights which may vary from state to state.
This device complies with FCC Part 15 and Canada Rules and Regulations. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée
aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,GLASS BREAK,ZW - P/N: 235512 X8 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - FOLDING: 4-FOLD ALTERNATE, FINISH WITH LOGO SHOWING - SCALE: 1-1
GLASS BREAK
DETECTOR
RED
2ND STAGE
INDICATOR
GREEN
1ST STAGE
INDICATOR
DETECTION
MICROPHONE
REMOVABLE
MOUNTING
BASE
MOUNTING
SCREWS
AND ANCHORS
TEST
BUTTON
BASE
ALIGNMENT
INDICATORS
INSERT TWO
CR123A BATTERIES
INTO BATTERY
HOLDERS
WARNING
DANGER OF EXPLOSION IF BATTERIES ARE
INSTALLED INCORRECTLY. REPLACE ONLY
WITH THE SAME OR EQUIVALENT TYPE
RECOMMENDED BY THE MANUFACTURER.
OBSERVE
POLARITY !!!
GREEN INDICATOR
WILL FLASH ONCE
WHEN BATTERIES
ARE INSTALLED
LOCATE THE DETECTOR ON THE
ADJACENT OR OPPOSITE WALL
OR ON THE CEILING
WITHIN
15 FEET OF THE WINDOW BEING
PROTECTED
1
2
USE THE MOUNTING BASE AS A
TEMPLATE TO MARK THE LOCATION
OF THE THREE MOUNTING HOLES
3
DRILL 3/16" PILOT HOLES FOR THE
SCREW ANCHORS AND PUSH
THE ANCHORS INTO THE HOLES
4
ATTACH THE MOUNTING BASE
WITH THE THREE SCREWS
NOTE: WHEN WALL MOUNTING,
ORIENT THE TEST BUTTON DOWN
5
ATTACH THE DETECTOR TO THE
BASE, MATCH THE ALIGNMENT
MARKS AND TURN CLOCKWISE
NOTE: IF THE BATTERIES ARE NOT
INSTALLED, THE DETECTOR WILL
NOT ALLOW MOUNTING TO THE BASE
MOUNTING
SCREWS
1
FROM THE IRIS WEB SITE, CLICK THE
DEVICES TAB
2
ON THE GLASS BREAK DETECTOR
DEVICE CLICK "MANAGE"
3
CLICK TEST
4
FOLLOW THE ON-SCREEN INSTRUCTIONS
TO TEST THE DETECTOR WITH THE HUB
WHEN INSTRUCTED,
PRESS THE BUTTON
ON THE DETCTOR
3 TIMES
AFTER INSTALLING BATTERIES, WAIT
5 SECONDS FOR THE POWER UP DELAY
1
2
FROM THE IRIS WEB SITE, CLICK THE
DEVICES TAB, THEN CLICK THE
"ADD DEVICES" BUTTON
5
FOLLOW THE ON-SCREEN INSTRUCTIONS
TO PAIR THE DETECTOR WITH THE HUB
4
PLACE DETECTOR WITHIN
10 FEET OF THE IRIS SYSTEM HUB
WHEN INSTRUCTED,
PRESS THE BUTTON
ON THE DETCTOR
3
SELECT GLASS BREAK DETECTOR
FROM THE LIST
1
FROM THE IRIS WEB SITE, CLICK THE
DEVICES TAB
2
ON THE GLASS BREAK DETECTOR
DEVICE CLICK "MANAGE"
3
CLICK REMOVE
4
FOLLOW THE ON-SCREEN
INSTRUCTIONS TO UN-PAIR THE
DETECTOR WITH THE HUB
PARING THE
DETECTOR
UN-PARING THE
DETECTOR
TO ADD
TO HUB
TO REMOVE
FROM HUB
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com

Summary of content (1 pages)