User's Manual

Copyright © 2016 Nortek Security & Control LLC 1
2GIG-RPTR1-345
WIRELESS INDOOR REPEATER
INSTALLATION INSTRUCTIONS
The2GIGWirelessIndoorRepeater(2GIGRPTR1345)isaremotely
poweredwirelessindoorrepeater.The repeaterisaperipheraldevice
thatcommunicate swiththe2GIGPanelusingaproprietary345MHz
transmissionprotocol.Therepeaterreceivesandrecognizesmessages
fromother345MHzdevicesthatareunabletodirectlycommunicate
withthesy
st
em,and“repeats”thosemessagestoextendtherangeof
thesedevices.
Therepeaterwilltypicallybeinstalledatthemidpointbetweenthe
panelandthewirelessdevicesbeingrepeated.Whenatransmission
fromadeviceisrepeated,therepeateraddsabittothemessageto
indicatetothesy
stemthattheme
ssageisnotcomingdirectlyfrom
thedevice.Therepeaterwillnotrepeatalreadyrepeatedmessages.
TherepeaterispoweredbyanACadapterandisequippedwitha
rechargeablebatterywhichsupports24hoursofbatterybackup
underconditionsoflocalpowerfailure.Whenthepo
wersourcefo
r
therepeaterchangesfromACpowertobatterybackup,orfrom
batterybackuptoACpower,therepeaterwillautomaticallysenda
messagetothesystemwithintwo(2)minutes.Inaddition,
supervisorymessagesaresentapproximatelyevery70minutesthat
indicatetherepeaterstatus.
Therepeaterisequippe
dwithast
atusindicatorLEDvisiblefromthe
frontoftheunit,andalearnbuttonislocatedonthesideoftheunit.
Figure 1 WirelessIndoorRepeaterPackageContents
Installing the Battery
Therechargeablebatterycanbeinstalledbyopeningtheenclosure
whilethepowerisdisconnected(seeFigure2).
WARNING: Polarityofthebatterymustbeobserved.Alignthe
batterytomatchthepolarityindicatorsonthecircuitboard.
Improperinstallationofthebatterymayresultinheat
generation,explosion,orfirewhichmayleadtopersonal
injury.
Installing the Repeater
Figure 2 Wireless Indoor Repeater Component and Feature Locations
Mounting Guidelines
Usetheseguidelineswheninstallingthewirelessindoorrepeater:
MountRepe
aterswithin100ft(30m)oftheControlPanel.
Althoughthetransmittermayhavearangeof350ft(106.7m)in
openair,therepeaterlocationcanhaveasignificanteff ecton
range.Inopen/unobstructedsituations,thetransmitterrangemay
begreater.Inadversewirelessconditions,changingthere
peater
orien
tationmayleadtoimprovedrange.
MountRepe
atersashighaspossible.Mountingtherepeaterhigh
offthegroundhelpsreceiversensitivity.
DoNotExpos
eRepeaterstoMoistureorExtremeTemperature.It
isbesttomountrepeatersinadrylocationwheretheoperating
temperaturedoesnotexceed32°to120°F(0°to49°C).
Ke
epRepeatersAwa
yfromMetal/MetalicSurfaces.Tokeepthe
repeaterawayfrommetalormetallicsurfaces(forexample,foil
wallpaper),itisrecommendedthatyouusespacers(notincluded).
Youshouldalsoavoidmountingsensorsinareaswherethereisa
largequantityofmetalorelectricalwiring(forexample,neara
furn
aceorinauti l
ityroom).
Toinstallthewirele
ssrepeater:
1 Opentherepeatercase.
2 Attachthebasetothedesiredwalllocationwiththefour(4)
Phillipsheadscrewsandanchorssupplied(seeFigure2).
3 Installthetamperscrew(seeFigure2).Withthetamperscrew
installed,removingthecasefromthewalltriggerstamper.
NOTE: Forthetampertoworkcorrectly,thetamperscrewmust
beinstalledintoawallstud.Donotuseawallanchor.
4 Installthebattery.Observebatterypolarity.
5 Connectthe2conductorwiretothepowersupplyandtothe
terminalconnectoronthecircuitboard.Makesurethewire
passesthroughthegrommetandholeontherepeaterbasebefore
connectingtotheterminal.
6 Attachtherepeatercovertothebaseandsecuretheassembly
withthePhillipsheadcaselockingscrew.
A RechargeableLithiumIonBattery
B ACAdapter
C Tampe rScrew
D MountingScrewsandAnchors(4)
E LearnButton
F StatusIndicator
G PowerInput
H CaseLockingScrew
H
G
F
E
B
A
C
D
1 RechargeableLithiumIonBattery 6 RepeaterBase
2 TamperSwitch 7 TamperScrew
3 Repeater 8 MountingScrews(4)
4 PowerInputConnector 9 MountingAnchors(4)
5 LearnButton
OBSERVE
BATTERY
POLARITY
1
2
3
4
5
6
7
8
9
PRINTER’S INSTRUCTIONS
10012437A-2GIG-RPTR1-345-INSTALL-INSTR-en-PRT, 09/16/2016, BLACK, 20LB MEAD BOND, 8.5X11”, TOL. +/- 0.125, SCALE: 1:1, FRONT & BACK, FOLD TO FIT BOX

Summary of content (2 pages)