Install Manual

Installation Instructions:
1. The HOT water service valve will have a red drain valve lever handle and a 3/4 threaded outlet for the pressure relief valve.
Install the included pressure relief valve using Teflon® tape into the 3/4 threads adjacent to the drain valve lever handle.
2. Loosen the union assembly on the valve and connect the 3/4fitting to the hot water outlet of the heater using Teflon® tape.
3. Tighten the union assembly to service valve making sure that the union nut is securely connected to the fitting and
that the rubber o-ring is securely in place.
4. The COLD water service valve will have a blue drain valve lever handle. Loosen the union assembly from
the valve and connect the 3/4” fitting to the cold water inlet of the heater using Teflon® tape.
5. Tighten the union assembly on the valve making sure that the union nut is securely connected to the fitting and that
the rubber o-ring is securely in place.
6. Connect the COLD water service valve to the cold water supply piping.
7. Connect the HOT water service valve to the hot water supply piping.
8. The drain valve lever handles should be in the closed position (lever perpendicular to the drain portion of the body)
during normal operation. Do not rely on the drain cap to stop the water from draining. Always remove the drain caps
slowly to ensure that no pressure exists.
Figure 1. Valve Detail (Cold Water Valve shown)
IK-WV-200-1 (3/4” - CSA 500,000 BTU/hr RELIEF VALVE)
Drain Cap
Main Valve
Wing Handle
Figure 2. Completed Installation
TOP
BOTTOM
Lever Handle
Cold Water
Service Valve
Water Outlet
Water Inlet
Hot Water
Service Valve
Pressure Relief Valve
SIDE VIEW
Cold Water
Service Valve
Water Outlet
Water Inlet
Hot Water
Service Valve
Bucket
Pump
Hose
Hose
Figure 3. Flush Procedure
Drain
SIDE VIEW
Drain
Water Heater Flush Procedure:
1. If not already on, turn the unit on with the Power Button on the
Remote Controller. If no Remote Controller is installed, ensure that
electrical power is supplied to the unit.
2. Close the gas supply valve.
3. Close both the hot and cold water valves with a quarter turn of the main
valve wing handle. The handle will be perpendicular to the main valve body.
4. Ensure the drain valve lever handles are closed on both the hot
and cold valve (the lever will be perpendicular to the drain portion
of the body) and slowly remove the drain caps.
5. Connect the pump outlet hose to the cold water drain valve on the
service valve as shown in Figure 3.
6. Connect a drain hose to the hot water drain valve outlet on the
service valve as shown in Figure 3.
•T•W•H•
I S O L A T I O N V A LV E S

Summary of content (2 pages)