ILD - IN’O USER GUIDE
ILD-IN’O User Guide NOTICE Nke Watteco reserves the right to make changes to specifications and product descriptions or to discontinue any product or service without notice.
ILD-IN’O User Guide DOCUMENT HISTORY Date May 2015 January 2016 Revision 1.0 1.1 1.
ILD-IN’O User Guide CONTENTS 1 Introduction.......................................................................................................................... 5 2 Start-up ................................................................................................................................ 5 3 Electronic input/output ......................................................................................................... 6 3.1 Electrical schematic example for inputs..................
ILD-IN’O User Guide 1 INTRODUCTION This document describes the usage of the ILD and IN’O sensor. It is necessary to read the IPSensor User Guide in prerequisite for all generic information. 2 START-UP The ILD and IN’O sensors manage two different power supplies, one is external and energizable in 9-15V the other one is internal on the battery. To use the external alimentation, just connect the right alimentation on the “Ext power” connector. Connect wires on Inputs and Outputs which will be used.
ILD-IN’O User Guide 3 ELECTRONIC INPUT /OUTPUT 3.1 ELECTRICAL SCHEMATIC EXAMPLE FOR INPUTS Due to limitation software, the maximum frequency is 500 Hz on each input. 3.
ILD-IN’O User Guide 4 HUMAN MACHINE INTERFACE There is three leds on the ILD and IN’O devices: ASS: FNC: CNF: blinking until the association to a network is done. blinking each minute while an input is activated. blinking in the configuration mode. A button user is available to enter in configuration mode. 5 APPLICATIVE LAYER The ILD and IN’O device is a sleepy device. It implements “ON/OFF” and “Binary Input” clusters, associated to their Outputs and Inputs.
ILD-IN’O User Guide Applicative payload is: 1106000f0004022300000e1000000005 6.2 CONFIGURE A STANDARD REPORT ON THE CONNECTOR INPUT 6+/6Specification: Report the counter all the 1 pulse on the connector Input 6+/6-. The counter has to be reported at less each 10 minutes, and a minimal timing of 10 seconds between 2 reports has to be setted to optimize the consumption. Solution: A counter on Input 6+/6- is the End Point 5, Cluster “Binary Input” is 0x000F, Attribut “Count” is 0x0402.
ILD-IN’O User Guide 7 APPENDIX 7.1 ILD FCC LABEL FCC ID: 2AGTV50-70-010 ILD SENSOR This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for FCC compliance could void the user authority to operate the device.