eNBioAccess-T2 User Guide Version eng-2.00 © Copyright 2013, NITGEN Co., Ltd. All rights reserved. ` It is strictly prohibited to compile, duplicate or publish part. Or whole of this manual prior written consent of NITGEN. The specification of this product may be changed without prior notice to improve its functionality. The logo of NITGEN&COMPANY is a registered trademark of NITGEN Co., Ltd. Other names or trademarks are registered trademarks of their respective owners.
eNBioAccess-T2 User Guide Version Date Description Firmware Version 1.00 2016-07-15 Initial Release 1000-01 1.10 1.20 2016-08-17 2016-09-01 1.30 2016-09-19 1.40 1.50 2016-09-29 2016-11-18 1.60 1.70 2016-12-01 2017-01-20 Modified the description for icon information.
eNBioAccess-T2 User Guide 3 Administrator (Admin) - The administrator can access the terminal menu mode. He/she has the authority to add/modify/delete terminal users and to change the operating environment by changing settings. - If there is no registered administrator in the terminal, anybody can access to the terminal menu and change settings. It is recommended that more than one administrator will be necessarily registered in the terminal.
eNBioAccess-T2 User Guide Table of Contents 1. Before Getting Started ................................................................................. 6 1.1. 1.2. Safety Notes ........................................................................................................ 6 Product Details ................................................................................................... 7 1.2.1. FRONT ...........................................................................................
eNBioAccess-T2 User Guide 5 3.6.1. Menu Configuration .................................................................................. 39 3.6.2. ADD.......................................................................................................... 39 3.6.3. AUTO ADD................................................................................................ 41 3.6.4. MODIFY .................................................................................................... 42 3.6.5. DELETE ...
eNBioAccess-T2 User Guide 1. Before Getting Started 1.1. Safety Notes Warning Do not operate the terminal with wet hands, and pay attention not to let any liquid such as water enter inside the terminal. - > Otherwise, malfunction or electric shock may be caused. Do not disassemble, repair or remodel the terminal at your disposal. - > Otherwise, it may cause malfunction, electric shock, or a fire. Keep the terminal away from inflammables. - > Otherwise, it may cause a fire.
eNBioAccess-T2 User Guide 1.2. Product Details 1.2.1. FRONT BLE embedded State LED Camera LCD Function KEY (F1~F4) Speaker Fingerprint Sensor Card Sensor (EM/SC/HID) USB assist device (UDL10) connection 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 1.2.2. REAR Fixed bracket Cable harness 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 1.2.3. Input / Output 1.2.3.1. Cable & Connector 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 1.2.3.2.
eNBioAccess-T2 User Guide 1.2.3.4. Terminal <- > LC015B wiring Category RS485A RS485B ground connection DOOR MONITOR T2 terminal (Line name) R4A (green) R4B (blue) GND (black) LC015B 485A 485B GND IN1(If this pin is not used, connect to GND Pin.) IN0 DC12V IN INSIDE OPEN DC12V (LC015B separate power supply) ground connection (Power only GND for LC015B) But, door open time can be set with DIP SWITCH of LC015B (Maximum open time is 5 sec.) 1.2.3.5.
eNBioAccess-T2 User Guide 1.3. Screen information during operation 1.3.1. Initial Screen When powering on at first, the screen is displayed as follow. State icon Operation Mode TNA Mode Date and Time 1.3.2. Icons NONE : No use network : LAN line is disconnected. Server connection State : LAN line is connected. (Only link is connected.) : Connected with server : Gate is closed. : Gate is opened.
eNBioAccess-T2 User Guide 1.3.3. Function KEY Icon Meaning Function Key Explanation UP F1 Move cursor up. DOWN F3 Move cursor down. LEFT ESC RIGHT F2 F2 long F4 F4 long or F4 Move cursor to left. Move to upper menu. Move cursor to right. F2 Category choice (ENABLE or DISABLE). ENTER ENABLE DISABLE Move to submenu. 1.3.4.
eNBioAccess-T2 User Guide Menu of Initial Screen Authentication succeess Authentication failure Waiting for Card Input Waiting for Fingerprint Input Waiting for Admin App registration Upgrading firmware for eNBioAccess-T2 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 1.4. LED information during operation LED RED Operating state Normal Alarm Remark Terminal Normal(alive) Enter menu OFF ON or Flash ON (Maintain during authentication time) OFF OFF ON ON (Maintain during authentication time) OFF Flash at intervals of 5 seconds Always ON Touch in initial screen. ON(Maintain for 10 seconds) OFF Authentication Failure GREEN Normal LOCK OPEN Authentication Success BLUE Function Key LED 1.5.
eNBioAccess-T2 User Guide 16 1.7. How to register and enter the correct fingerprint Correct fingerprint input method Enter your fingerprint as if you take a thumbprint by using your forefinger if possible. The fingerprint cannot be correctly registered and entered only by your fingertips. The center of the fingerprint should be touched with the fingerprint input section. Enter the fingerprint of your forefinger if possible.
eNBioAccess-T2 User Guide 17 It is recommended that you will register more than two fingerprints if possible. In order to increase the fingerprint authentication rate, it is recommended to use six of the ten fingers as illustrated below (both thumbs, forefingers, middle fingers). 2. Product Descriptions 2.1. Product Features BLE is equipped. Door Control with smartphone is possible at close range.
eNBioAccess-T2 User Guide 2.2. Diagram 2.2.1. Single Type (Door Lock) Close BLE 2.4G Mobile App Lock control Open T2 Door Lock 2.2.2. Single Type (Lock Controller) Close RS485 BLE 2.4G Open Mobile App T2 Lock Controller (LC010, LC015) 2.2.3. Dummy Type (MCP040) Lock/Open RS485ID #1 Lock/Open RS485ID #2 Ethernet RS485 Lock/Open RS485ID #3 Server MCP040 T2 12F, Daemyung Valeon bldg.
eNBioAccess-T2 User Guide 2.2.4. Network Type (Door Lock) Close BLE 2.4G Lock Control Mobile App T2 Ethernet Open Door Lock Internet Ethernet Server 2.2.5. Network Type (Lock Controller) Close RS485 BLE 2.4G Open Mobile App T2 Lock Controller (LC010, LC015) Ethernet Internet Ethernet Server 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 2.3. Product Specification Category CPU MEMORY Camera LCD Fingerprint Sensor Authentication Method Authentication Speed Fingerprint capacity Log capacity Communication interface Lock Temperature / Humidity Certification Size Spec 32Bit RISC CPU(400MHz) 64M DDR RAM, 32M NOR,128M NAND VGA, F2.8, View angle 61 degree 1.77’’ Color LCD Optical / 500 DPI Fingerprint, RF Card, Mobile Card 1:N < within1sec.
eNBioAccess-T2 User Guide 3. Environment Setting 3.1. Checkpoints before Environment Setting 3.1.1. Menu Press F4 long until the menu screen is displayed. It is available to enter the menu without authentication because the manager doesn’t register when shipping the product. 3.1.2. Administration authentication When the administrator is registered, the admin authentication screen is displayed at first as follows.
eNBioAccess-T2 User Guide 3.1.3. How to access the menu without administrator authentication This is the method to enter the Menu in exceptional cases such as losing your administrator card that is registered in the terminal or inability to make a fingerprint authentication because of absence of administrator. ① Power terminal OFF. ② Disassemble device and make case open state. ③ While case opens, make DIP of rear side switch ON state as follows. ON 1 OFF 2 ON ④ Power terminal ON.
eNBioAccess-T2 User Guide 3.1.5.
eNBioAccess-T2 User Guide BIT or 34 BIT > SITE CODE > SEND INFO 3.1.6. Setting guide for Network Configuration 3.1.6.1. Single Type (Door Lock=STRIKE) Menu position MENU>NETWORK> MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE MENU>EXT DEVICE>DOORLOCK>DM0 MENU>EXT DEVICE>DOORLOCK>LOCK2>TYPE MENU>EXT DEVICE>DOORLOCK>DM1 MENU>EXT DEVICE>DOORLOCK>DM2 MENU>EXT DEVICE>RS485>TYPE Possible setting NO USE STRIKE/OK N/O or N/C NONE NONE NONE NONE 3.1.6.2.
eNBioAccess-T2 User Guide MENU>EXT DEVICE>RS485>TYPE MENU>EXT DEVICE>RS485>DEV ID LC015 0 3.1.6.5. Dummy Type (RS485=MCP040) Menu Position MENU>NETWORK> MENU>EXT MENU>EXT MENU>EXT MENU>EXT MENU>EXT MENU>EXT MENU>EXT DEVICE>DOORLOCK>LOCK1>TYPE DEVICE>DOORLOCK>DM0 DEVICE>DOORLOCK>LOCK2>TYPE DEVICE>DOORLOCK>DM1 DEVICE>DOORLOCK>DM2 DEVICE>RS485>TYPE DEVICE>RS485>DEV ID Possible setting N/A (Use : When only downloading DB) NONE NONE NONE NONE NONE MCP040 Use in 1~7 3.1.6.6.
eNBioAccess-T2 User Guide MENU>EXT DEVICE>DOORLOCK>DM2 MENU>EXT DEVICE>RS485>TYPE 3.1.6.8. Network Type (Lock Controller=LC010) NONE NONE Menu Position MENU>NETWORK> MENU>NETWORK>USE>AUTH MODE MENU>NETWORK>USE>TERMINAL ID MENU>NETWORK>USE>TERMINAL>STATIC Possible setting Use TN 0001 IP:192.168.0.3 SN:255.255.255.0 GW:192.168.0.1 IP:192.168.0.
eNBioAccess-T2 User Guide 3.2. How to register the terminal in Admin App 3.2.1. Install iAccess M Plus iAccess M Plus is the smartphone App for administrator controlling device via BLE. You can download and install it from Play Store. For more details, please refer iAccess M Plus installation guide. 3.2.2. Execute and Log in iAccess M Plus 3.2.3. Access to Terminal BLE REDAY If you press F3 long on initial screen, the terminal turns to BLE READY. 12F, Daemyung Valeon bldg.
eNBioAccess-T2 User Guide 3.2.4. Terminal login Admin App When the terminal is BLE REDAY, press ADD on iAccess M Plus App and select the terminal. If you know the administrator's ID and password, then click OK to log in. If you do not know the administrator’s ID & password and click OK in empty state. 3.2.5. Administrator authentication of the terminal If an administrator is registered in the terminal, it requires to input card or fingerprint for administrator authentication.
eNBioAccess-T2 User Guide 29 3.3. Access Device with Admin App If the terminal registration on Admin App is successful, the list is displayed as follows. When pressing View, the pop-up window is displayed to connect the terminal. If the administrator is registered in the terminal, it requires the administrator authentication. If there is no administrator, the login succeeds immediately. If the login is successful, you receive the list of users registered with the Admin App screen.
eNBioAccess-T2 User Guide 3.4. Access and Registration between ACM Pro and terminal 3.4.1. Install ACM Pro When shipping the product, it installs ACM Pro Program in PC from the provided CD. For installation guide, please refer the relevant document. 3.4.2. Execute ACM Pro If executing the program, login screen is displayed. Enter User ID that is previously registered and password and then press OK. If login is successful, the screen is displayed as follows. 12F, Daemyung Valeon bldg.
eNBioAccess-T2 User Guide 31 3.4.3. Set in terminal In order to connect the terminal to the server, set to the network mode and set the information. Move to MENU > NETWORK > USE > TERMINAL and check whether lower information is correct or not. If you have not changed the device network information, it is displayed as follows. In order to access the server Move to MENU > NETWORK > USE > SERVER and check the lower information correctly sets or not.
eNBioAccess-T2 User Guide 32 3.4.5. Register the terminal in ACM Pro Select the unregistered terminal and press Registration button to activate the screen below. Enter device name and explanation to press OK. If the registration is successful, the screen is displayed as follow. For more details about ACM pro operation, please refer ACM Pro guide document. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.
eNBioAccess-T2 User Guide 3.5. Menu Configuration The whole menu is composed of seven, and main characteristics are as follows. Menu USER Submenu1 ADD Submenu2 USER Submenu3 USER ADMIN INPUT ID *Authentication Type Card FP MCARD *Authentication Condition OR AND ※ MCARD is OR condition only. AUTO ADD MODIFY ※ MCARD is not admitted to set up, state check only. Password FP Card INPUT ID *Authentication Type Card FP MCARD *Authentication Condition OR AND ※ MCARD is OR condition only.
eNBioAccess-T2 User Guide NETWORK NO USE USE Operate in single mode AUTH MODE TERMINAL ID STATIC DHCP STATIC Server/Terminal Terminal/Server Server Terminal TERMINAL ID IP Subnet mask Gateway DHCP SERVER OPTION ATTEND TYPE AUTO TNA SCREEN LANGUAGE ENGLISH(0) KOREAN(1) INDONESIAN(2) MULTILINGUAL(3) ARABIC(4) SPANISH(5) PORTUGUESE(6) FRENCH(7) RUSSIAN(8) FARSI(9) JAPANESE(10) CHINESE(11) SHOW ID USER LOGO SAVE USER ID LEN LOG SAVE IMAGE SAVE TIMEOUT Date RESULT NET ERROR PING FORM 12F, Da
eNBioAccess-T2 User Guide SETTING INT DEVICE FP SENSOR BEEP VOICE BLE TAMPER EXT DEVICE DOOR LOCK 1:1 LEVEL (1~9) 1:N LEVEL (5~9) LFD LEVEL AUTH TIME 0~3 0~5 BLE READY NO ALARM ALARM LOCK1 LOCK2 OPEN ALARM TIME DM0 DM1 DM2 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide RS485 TYPE WIEGAND DEV ID: 0~255 WIE-INPUT WIE-OUTPUT NONE LC010 LC015 SR100 MCP040 *TYPE NONE WIE26BIT WIE34BIT CUSTOM *TYPE NONE WIE26BIT WIE34BIT CUSTOM *SiteCode *More Information UID CARD STATE DB INFO NETWORK OPTION USER CNT: USER MAX: ADMIN: FP CNT: FP MAX: CARD CNT: CARD MAX: M.CD CNT: LOG CNT: LOG MAX: TID: xxxx NET: YES, MODE:TN NET TYPE: STATIC ENCRYPT: DES CIP/SN/GW--------xxx.xxx.xxx.xxx xxx.xxx.xxx.xxx xxx.xxx.xxx.
eNBioAccess-T2 User Guide INT DEVICE EXT DEVICE DATE: YYMMDD LOG SAVE: YES IMG SAVE:NO SHOW TO: x PING TO: x NET TO: x: CARD TYPE: RF/SC CARD FMT: STD FP1:1:x FP1: N:x LFD: xx AUTH TIME: BEEP VOL: VOICE VOL: BLE Name/MAC---XXXXXXX (BLE Name) XXXXXXXXXXXXXXXXX TAMPER:ALARM LOCK1---------------------TYPE: STRIKE/OK OUT: N/O OPEN: 3000ms LOCK2 ------------------TYPE: NONE OUT: N/O OPEN: 3000ms DOOR WARN: 0sec FORCE OPEN:NO I/O PORT VERSION RS485: LC010 RS485 ID: xxx WIEGAND---------------IN/OUT :34B/
eNBioAccess-T2 User Guide RECOVERY INITIALIZE SELF TEST SN(Serial Number) CONFIG LOG DB FACTORY INT DEVICE EXT DEVICE BACKUP LOG EXPORT USER EXPORT USER IMPORT FW UPDATE REBOOT 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 39 3.6. USER 3.6.1. Menu Configuration USER menu has the feature as follows. Category ADD AUTO ADD MODIFY DELETE DELETE ALL Explanation Use to add user and admin with various certification conditions. Use to add Card or Fingerprint user automatically. Use to add certification conditions, card or fingerprint of registered user. Use to delete a registered particular user. Use to delete all registered users. 3.6.2. ADD 3.6.2.1.
eNBioAccess-T2 User Guide ADMIN 3.6.2.2. Available to add and delete user. Available to access menu and modify it. When selecting the administrator, the screen is displayed as follows. AUTH TYPE There are FP(Fingerprint), Card, and MCARD (Mobile card) in the menu. But MCARD can only provide the check state, and do not provide checking or unchecking. For checking or unchecking with MCARD, it is only available via Server and Admin App. There are AND and OR in authentication conditions.
eNBioAccess-T2 User Guide 3.6.2.3. INPUT FP Input the same fingerprint twice when you check the Fingerprint as authentication type. If you want to add only one fingerprint, select 1. NO. If you input the fingerprint second times and they are normal, INPUT OK is displayed. If you want to add more fingerprints, select 2. YES. One user can register 20 people for maximum. 3.6.2.4. INPUT CARD When you check Card as AUTH TYPE, you will follow steps as below.
eNBioAccess-T2 User Guide 42 3.6.3.1. AUTO ADD – 1. FP This is the menu when registering the users continuously only by fingerprint. Input fingerprint in twice and then the registration succeeded. If you want to add more users, select 2. YES, and continue the registration. User ID increases automatically. 3.6.3.2. AUTO ADD This is the menu when registering the users continuously only by card. After inputting the card, INPUT OK is displayed on the screen. If you want to add the other user, select 2.
eNBioAccess-T2 User Guide 43 3.6.5. DELETE It is used when deleting the registered users. 3.6.6. DELETE ALL It is used when deleting all the registered users. It should be careful when trying to delete, because all the users (general user, administrator) are deleted. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 3.7. Network Menu 3.7.1. Menu Configuration Network menu has the following features. Category NO USE USE Explanation Network not used AUTH MODE TERMINAL ID TERMINAL SERVER Operation Mode Standalone Explanation This is the operation mode independently without server and communication. The administrator can control all the functions of the terminal. Authentication log is saved in the terminal but is not sent to server.
eNBioAccess-T2 User Guide 45 3.7.2. AUTH Mode Authentication mode means the authentication priority to determine whether authentication processing is done in the terminal or the server when user-authentication. It is a valid setting only when using the network. All authentication log is sent to server through the network. AUTH MODE Server/Terminal Explanation Server Terminal After trying to do server authentication at first, terminal authentication is processed.
eNBioAccess-T2 User Guide 3.7.4. Terminal It is used when setting the network information in the terminal. Network setting in the terminal can be set in Static IP and DHCP. STATIC: Set the value as a user wants. DHCP: Allocated flexibly. (It can be operated normally when using the router supporting DHCP.) If STATIC is used, it is used when setting IP, Subnet mark and Gateway address of the terminal. The following is the default setting value.
eNBioAccess-T2 User Guide 3.7.5. Server When the terminal accesses in server through the network, set the information. Default setting value is as follows. Category Server IP Port number Default Setting Value 192.168.0.2 7332 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 3.8. Option Menu 3.8.1. Menu configuration User menu has the same function as follows. Category ATTEND SCREEN SAVE TIMEOUT LOCKING Explanation TYPE AUTO TNA LANGUAGE SHOW ID USER LOGO USER ID LEN DATE LOGO SAVE IMAGE SAVE RESULT NET ERROR PING NO USE / USE 3.8.2. ATTEND TNA related menu are configured. Category TYPE Explanation When Function Key is used in time and attendance option, it is used.
eNBioAccess-T2 User Guide 3.8.2.1. TYPE It is used when setting ATTEND mode. If setting ATTEND mode, ATTEND mode is displayed in the screen when pressing Function Key shortly (F1~F4) in the default screen. Mode NONE F1~F2 F1~F4 F1~F49 Function Key F00 F01 F02 F03 F04 F11~F49 Explanation F00 is only displayed in default screen. F1~F2 Function Key is recognized and F01, F02 are displayed in default screen. F1~F4 Function Key is recognized and, F01, F02, F03, F04 are displayed in default screen.
eNBioAccess-T2 User Guide 50 3.8.3. Screen The screen display related menu is configured. Category LANGUAGE SHOW ID USER LOGO Explanation Change the language which is displayed in the screen and is spoken. When authentication succeeds, you can set whether showing ID or not. You can set whether the logo image for customers is used or not in the default screen. It is used when modifying the length of user’s ID. It is used when modifying Year/ Month/ Day and time displayed in the default screen.
eNBioAccess-T2 User Guide USE When authentication successes, it shows user’s ID on the screen. For example, “****”. 3.8.3.3. USER LOGO It is used to determine whether the displayed image shows the customer’s logo or not in the default screen.
eNBioAccess-T2 User Guide 52 3.8.3.4. USER ID LEN It is used to change the length of user’s ID. If changing the user’s ID, it should change in the absence of a DB because it affects user’s DB that is internally registered. The setting range can be set from 4 to 16. If a user registered in the terminal exist, you can’t change the length of User ID. 3.8.3.5. DATE It is used to select the order of Year, Month and Day displayed in the default screen.
eNBioAccess-T2 User Guide 53 3.8.4.1. LOG SAVE It is used to set whether to save the authentication log in memory or not. The default setting is YES. 3.8.4.2. IMAGE SAVE It is used to set whether to save the captured photo from camera when authentication successes or fails. The default setting is Fail. 3.8.5. TIMEOUT It is the menu that has the setting related with timeout. 3.8.5.1. RESULT It is used to set the authentication result display how long it keeps for a seconds. 12F, Daemyung Valeon bldg.
eNBioAccess-T2 User Guide 54 The setting range can be set from 0 to 5 seconds. If it set to 0, then don’t display the authentication result. 3.8.5.2. NET ERROR If it does not communicate with the server over a period of time, it is used to set whether there is a network communication error. If PING doesn’t come for a setting time in the server, it retries to connect the terminal. The setting range is available for 60~600 seconds. 3.8.5.3.
eNBioAccess-T2 User Guide The default screen is displayed as follows when setting to use locking mode. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 3.9. INT DEVICE 3.9.1. Menu Configuration INT DEVICE menu has the features as follows. Category FP SENSOR BEEP VOICE BLE TAMPER Explanation 1:1 LEVEL 1: N LEVEL LFD LEVEL AUTH TIME Set Beep Sound. Set Voice Sound BLE registration mode Set the alarm when opening terminal case. 3.9.2. FP SENSOR For the fingerprint recognition, it sets for the user registration and authentication about the module installed inside. 3.9.2.1.
eNBioAccess-T2 User Guide 57 3.9.2.2. 1: N LEVEL It is the authentication level used when it tries 1: N fingerprint authentication. 3.9.2.3. LFD LEVEL It sets LFD LEVEL to prevent the duress fingerprint. If setting LFD LEVEL higher and higher, the ability to prevent the input of duress fingerprint produced by rubber, paper, film, and silicon etc. reinforces but too dry fingerprint cannot be input well. Also the authentication speed can be slow. 3.9.2.4.
eNBioAccess-T2 User Guide 58 3.9.3. BEEP It informs key touch, authentication success, and failure as beep and sets the beep level. The beep level is available from 0 to 3. 3.9.4. VOICE It supports the notice such as authentication success/failure and authentication retrial. It sets the authentication level. The voice level is available from 0 to 5. 3.9.5. BLE When registering the terminal in Administrator’s App, this menu is required. By using this menu, it can make the terminal BLE READY.
eNBioAccess-T2 User Guide 3.9.6. TAMPER When disassembling the terminal randomly, it sets whether to sound the alarm. If selecting 1. NO ALARM, even if disassembling the terminal, the alarm doesn’t sound but icon is displayed. If selecting 2. ALARM, icon displays and the beep sounds in at regular intervals. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 60 3.10. EXT DEVICE 3.10.1. Menu Configuration EXT DEVICE has the features as follows. Category Explanation DOORLOCK It sets the control device to lock through the internal relay. RS485 It sets the devices using RS485. WIEGAND It sets the device using WIEGAND. 3.10.2. DOORLOCK It is the menu to set lock device (Strike, Motor type door lock) by using LOCK1 and LOCK2 port. 3.10.2.1.
eNBioAccess-T2 User Guide 3.10.2.2. LOCK1 OPEN TIME It sets the time to give the signal when LOCK 1 sets 2. STRIKE/OK. Strike type means the time from opening to locking the door after authenticating. The default value is 3 seconds and the input range is 1 to 20 seconds. 3.10.2.3. LOCK2 type NONE FAIL IND MOTOR2 When not using When connecting the light to mark authentication failure in Lock 2 When connecting motor lock 3.10.2.4.
eNBioAccess-T2 User Guide 62 3.10.2.6. DM0 DM0(Door Monitor 0) is the input port and it is used to detect the signal state of door open. 3.10.2.7. DM1 DM1(Door Monitor 1) is the input port and it is used to detect the signal state of lock. 3.10.2.8. DM2 DM2(Door Monitor 2) is the input port and it is used to detect a various of sensor and alarm. For example, if connecting with fire sensor, it should set 4. FIRE N/O or 5. FIRE N/C and it may cause fire alarm and icon in case of fire.
eNBioAccess-T2 User Guide 63 3.10.3. RS485 It is the setting for the device with RS485 communication to interface with external. 3.10.3.1. TYPE TYPE NONE LC010 LC015 SR100 MCP040 Explanation It doesn’t use RS485. Lock Controller It controls LOCK through the other external module. Lock Controller It controls LOCK through the other external module. FP Dummy Reader When it installs the other FP dummy reader device in external and then operates, it is used. Terminal operates as the dummy reader.
eNBioAccess-T2 User Guide 64 3.10.3.2. DEV ID DEV ID is the ID that distinguishes devices and it can be set up 0-7 during RS484 communication. 3.10.4. WIEGAND WIEGAND supports each one of Input port and Output port. 3.10.4.1. WIE-INPUT It is used to set the input type when working with the device connected into WIEGAND input port. Category NONE WIE26BIT WIE34BIT CUSTOM Explanation WIEGAND input port is not used.
eNBioAccess-T2 User Guide 3.10.4.2. WIE-OUTPUT Category NONE WIE26BIT WIE34BIT CUSTOM Explanation WIEGAND output port is not used. EM, HID26 Card Module Mifare Card Modules Use Access Manager program and set Wiegand format. 3.10.4.3. CUSTOM BIT LENGTH It can set BIT length as 1~128. 3.10.4.4. SITE CODE It is used to set the value of Site Code that is sent to WIEGAND output port. 3.10.4.5. SEND INFO It is used to select the transmitting data by the output port. 12F, Daemyung Valeon bldg.
eNBioAccess-T2 User Guide SEND INFO USER ID Type 26 Bit 34 Bit None E.Parity(1)+ Site Code(8bit) + ID(16bit) + O.Parity(1) E.Parity(1)+ Site Code(8bit) + ID(24bit) + O.Parity(1) If the length of the User ID greater than 8, and sent in the following format without site code: Card 26 Bit 34 Bit E.Parity(1)+ ID(32bit) + O.Parity(1) E.Parity(1) + 24bit Card Number+ O.Parity(1) E.Parity(1) + 32bit Card Number + O.Parity(1) 12F, Daemyung Valeon bldg.
eNBioAccess-T2 User Guide 67 3.11. STATUS 3.11.1. Menu Configuration STATE menu has the STATE information DB INFO NETWORK OPTION INT DEVICE EXT DEVICE I/O PORT VERSION following features. Explanation User DB, Authentication log data The setting information related to network TNA, Screen setting, Saving, Time out, Lock mode Display the setting state related to the internal device. Display the setting state related to the external device.
eNBioAccess-T2 User Guide 3.11.4. OPTION It displays the option setting value. 3.11.5. INT DEVICE It displays the setting value related to the internal device. 3.11.6. EXT DEVICE It displays the setting information related to the external device. 3.11.7. I/O PORT It reflects the current I/O Port state and displays it on the screen. Output Port: LOCK1, LOCK2 Input Port: DM0~DM2, W0IN, W1IN, INSIDE Open, Tamper When the input port shorts GND, the signal modifies from HIGH to LOW.
eNBioAccess-T2 User Guide 3.11.8. VERSION It displays the equipped module in the terminal and other version information. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 70 3.12. RECOVERY 3.12.1. Menu Configuration RECOVERY has the features as follows. Category INITIALIZE SELF TEST BACKUP REBOOT Explanation CONFIG LOG DB FACTORY INT DEVICE EXT DEVICE LOG EXPORT USER EXPORT USER IMPORT FW UPDATE REBOOT 3.12.2. INITIALIZE It is used to initialize CONFIG, LOG DB, and FACTORY in the terminal. 3.12.2.1. CONFIG It is used to initialize the modified setting value in the menu as the default value when shipping from factory.
eNBioAccess-T2 User Guide 71 3.12.2.2. LOG DB INIT It is used to delete the user authentication log saved in the terminal. 3.12.2.3. FACTORY INIT If trying FACTORY INIT, setting data, authentication log data, and user registration information are initialized as setting state when shipping from factory. ★ It should be careful because the current data can be lost when you setting wrong. 3.12.3. SELF TEST It is used when the terminal tests the operation state about internal & external device by itself.
eNBioAccess-T2 User Guide 3.12.3.1. INT DEVICE It could test VOICE, CARD, FP SENSOR, CAMERA and LED equipped internally by itself. Category VOICE CARD FP SENSOR CAMERA LED Explanation Voice output test Card recognition test Fingerprint recognition test Camera equipment test LED output test Voice Test When authentication successes, it repeats and play voice guidance. Card Test As you see below, the screen displays “INPUT CARD” state at first.
eNBioAccess-T2 User Guide Camera Test It is used to check whether the camera state is normal in the terminal to capture photos. LED Test It is used to check whether the state is normal about RED, GREEN and BLUE LED used to inform the operation state. At intervals of 2 seconds, RED, GREEN and BLUE LED changes from ON to OFF. 3.12.3.2. EXT DEVICE It can test the features related to the external device by itself.
eNBioAccess-T2 User Guide DOORLOCK Test It is used to check the state of LOCK1, LOCK2 OPEN /CLOSE from the terminal. The procedure is as follows. SENSOR IN It is used to check the signal state about the input port. When the port shorts GND, if signal changes LOW, it is normal. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 3.12.4. BACKUP When the saved data from the terminal sends to USB by using UDL device or brings the data from USB memory and then applies it, it is used. It is available only when the UDL module is. UDL is the option module, so it is not basically provided. If you want to get more information about UDL module, please contact NITGEN customer service. USB memory recommends using Sandisk.(NOTICE: UDL Device is not supported for all USB memory.
eNBioAccess-T2 User Guide or 3.12.4.2. USER EXPORT The saved User DB from the terminal saves in USB memory through UDL. It saves as USER.NDB file. or 3.12.4.3. USER INPUT It reads the user DB from USB memory through UDL and add it in terminal user DB. If inputting user DB in the terminal, all existing user DB are deleted. If you need the existing user DB saved in the terminal, back up first and try to input the user. It opens USER.NDB file in USB memory and brings into the terminal through UDL.
eNBioAccess-T2 User Guide 3.12.5. REBOOT It is used when rebooting the terminal. 12F, Daemyung Valeon bldg., 127, Beobwon-ro, Songpa-gu, Seoul, Korea (05836) Tel : 02-6488-3232 , Fax : 02-6488-3099, E-Mail :customer@nitgen.com http://www.nitgen.
eNBioAccess-T2 User Guide 78 FCC Information This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) This Device may not cause harmful interface, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules.