Wiring Diagram

Table Of Contents
This function inside the motion sensor to achieve tri-level control, for some areas which require a light change
notice before switch-off. The sensor offers 3 levels of light: 100%-->dimmed light (natural light is insufficient)
-->off; and 2 periods of selectable waiting time: motion hold-time and stand-by period; Selectable daylight
threshold and freedom of detection area.
With suffcient natural light, the
light does not switch on when
presence is detected.
With insufficient natural light,
the sensor switches on the light
automatically when presence
is detected.
After hold-time, the light dims to
stand-by level if the surrounding
natural light is below the
daylight threshold.
Light switches off automatically
after the stand-by period
elapses.
Corridor Function
The ANT-5-4 is a motion sensor that dims lighting from high to low based on movement. This slim, low-profile
sensor is designed for installation inside the bottom of a light fixture body.
The sensors use microwave sensing technology that reacts to changes in movement within the coverage area.
Once the sensor stops detecting movement and the time delay elapses lights will go from high to low mode and
eventually to an OFF position if it is desired. Sensors must directly see” motion of a person or moving object to
detect them, so careful consideration must be given to sensor luminaire placement and lens selection. Avoid
placing the sensor where obstructions may block the sensors line of sight.
-1- -2-
INTRODUCTION
SPECIFICATIONS
Bi-level Microwave Sensor For High Bay Light
ANT-5-4 Instruction
Bi-level Microwave Sensor For High Bay Light
ANT-5-4 Instruction
RC-100
Every 30min
Check
Hold-time ends
Power On
Dim
100% On
Off
motion
No motion
When the natural light
level exceeds setpoint
off to light,the light will
turn off even if when the
space is occupied.
100% on when movement
detected, and dims to 10%
in long absence.
1 3
goes in cycle
at night
...
4
08:10
The light automatically turns
on at 10% when natural light
is insuffcient (no motion).
5
17:40
Daylight Sensor Function
Open the daylight sensor by push when remote control is in setting condition.
The light dims to stand-by
level after the hold-time.
The light switches on at
100% when there is
movement detected.
1
21:00
The light remains in dimming
level at night.
3
21:40
2
21:10
Settings on this demonstration:
Hold-time: 30min
Setpoint on:50lux
Stand-by Dim: 10%
Stand-by period: +∞
Setpoint off:300lux
(when the smart photocell sensor open, the stand-by
time is only +∞)
SENSOR COVERAGE
Cove rage Side View
0' 6' 12' 30'12' 6'30' 20' 20'
0
10'
20'
30'
40'
'
0' 3' 6' 12'
30'
12' 6'3'27'
30'
20'
20'
0'
3'
6'
3'
6'
12'
27'
30'
12'
27'
20'
20'
60 ft
30'
27'
V1.2
41.3
12.57.5 7.3
43
G1/2
51
2-R1.6
55
23°
ANT-5-4
ANT-5-4T sensor
ANT-5-4B
connecting base
Cable length:
300mm
WARNING
NOTE: Warmuptimeis15seconds.Afterthesensorconnectsinputpowerfirsttime, thelightwillkeepon15seconds,
thengo to dimmingtoworknormally.
NOTE: Factory Default Setting: 100% sensitivity, Hold on time: 5min, Daylight sensor is , Dimming level:
30%,Dimming time: 60minitues.
NOTE: Any setting changed by remote control, the led light that sensor connect will on/off as confirm.
Cable specifications:
AWM 2464 /22AWG
/80/300V
18.4
24.8
25
28.5
23.2
31.2
3-
2.3 9
44
189
G1/2
0-10V, max. 25mA sinking current
12V-24V DC, >50mA
5.8GHz±75MHz
Detection radius
20%/50%/75%/100%(1-8m)
Max 50ft.(15meters)
IP65
-4°F ~ +140°F (-20°C ~ +60°C)
10s/1min/5min/10min/15min/20min/30min/60min
24H/10LUX/30LUX/50LUX
Dim control output
Power supply
HF System
Mounting height
IP rating
Temperature
Time setting
Light-control
Transmission power
<0.2mW
WIRING DIAGRAMS
12V
DIM-
LED+LED-
DIM+
L
N
LED Driver
L
N
0-10V
Black: 12-24Vdc
Gray: DIM -
Purple: DIM +
FCC STATEMENT
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Summary of content (1 pages)