Assembly Instructions

Part NO. Country Frequency Comments
PD-V10-501
PD-V10-502
PD-V10-502
UK 10.587 GHz (5V)
Belgium, Holland, Italy 10.525 GHz (5V) Meets RED Directive
USA 10.5-10.55 GHz (5V) FCC-ID
PD-V10-301
PD-V10-302
UK 10.587 GHz (3V)
Belgium, Holland, Italy 10.525 GHz (3V) Meets RED Directive
Environmental Characteristics
Key Features
• Low Cost
• High Sensitivity
• Patch Antenna
• Low Power consumption
• 3V and 5V versions available
• RoHS compliant
Applications
Coverage Pattern
• Intrusion Alarms
• Automatic Door Openers
• Presence Sensing
X-Band Doppler Motion Detector Unit
Model:PD-V10-G5
The Microwave Solutions PD-V10-G5 Motion Detector Unit is a miniature X-Band microwave transceiver that
utilises the Doppler shift phenomenon to "sense" motion.
The unit, housed in a metal can, features a dielectric resonator stabilised oscillator, which provides stable
operation over a broad temperature range in either CW or low duty cycle pulse mode and an integrated
homodyne receiver for enhanced sensitivity and reliability.
This module family is available with either a +5v or +3v supply voltage.
Operation
The basic principle of operation consists of detecting the frequency shift between a transmitted and a received signal
reflected back from a moving object within the field of view of the unit.
The unit produces a low level output signal which can be amplified and processed to provide an audible or visual alarm
signal and employs low cost surface mount manufacturing techniques which are field proven as being rugged and
reliable.
Available Modules
Electrical Characteristics
Transmitter
Antenna : standard Mechanical Characteristics
Pulse Mode Operation
Frequency See table over
Power Output (Min.) 12 dBm EIRP
Operating Voltage +5 V ± 0.25 V
+3 V ± 0.15 V
Operating Current (CW) 25mA (max)
20mA (typ)
Harmonic Emissions <-30dBm
Average Current (5% DC) 1 mA typ.
Pulse Width (Min.) 5 µsecs
Duty Cycle (Min)
Pulse Repetition Frequency
1%
2-4 KHz
Receiver (Bandwidth 1Hz~3KHz)
Sensitivity (for a 10 dB S/N ratio) -84 dBm
Noise (measured in a 3Hz to 80Hz bandwidth) < 30 µV
Gain 5 dBi
-3 dB Beamwidth
E Plane 50°
H Plane 60°
Weight 4 g
Pin header connectors 2.54mm spacing X3
RoHS Compliant
Power/Temp. Coefficient (over operating temp. range) 3 dB
Frequency/Temp. Coefficient (over operating temp. range) 6.5 MHz
Operating Temperature -20° C to +70° C
www.pdlux-solution.com www.pdlux.com Tel: 86-574-83008608(20 lines)
9mm
Xmm
27mm
17.6mm
+5VIF
GND
Horizontal
Vertical
NOTES
The strength of the sensor's output detection rangedepends on the Signal to Noise Ratio.
Higher or lower than the nominal operating temperature, the sensor can also work, but the performance will be reduced.
To avoid damage to the devices, care should be exercised during handling. Proper Electrostatic Discharge (ESD)
precautions should be observed at all stages of storage, handling, assembly, and testing.

Summary of content (5 pages)