Installation Instructions

A/01
dial switch
muti-function button
DC510
Method of use
If vabration continues,the sensor will stand
by after motor closed;If vabrate happens
randomly,the motor will standby directly.
after the vabration reaches the set level,the awning
will open,then press muti-function button with a
beep hint,but do not release,then a beep again
as a hint of direction changed.
DC510
When there is a vibration,reaching
setting point,DC510 launch three
times code.
(30s quit the sense
statue after one order is transmitted)
pack up awning
when coltage is below 2.2V,it
will beep every 5s to remind
the battery changing.
there are ten level of intensity of vibration, increase from level 0 to
level 9 , and customers can set different class as per their demands.
Only when the vibration strength reaches the certain set value, can
the emitter be triggered and then emit signal to withdraw the roller
blinds. The emitter will emit signalthree times after it detects the
vibration, thus can make sure to withdraw the roller blinds.level 1
is the most sensitive one,level 9 is the least.level 0 sense nothing.
place the cover after operation,it will enter the normal working statue.
muti-function button:
0 level--set button,
5 level--up button,
9 level--down button.
All the parameters to the nameplate shall prevail
3V
control awning open and
close through vibration sensor
DC510 shake sensor
Set vibration grade:
Working principle:
power supply voltage: DC 3 V (two
batteries of number seven)
Working temperature-20~55
Emission power10 milliwatt
awning
open the outer shell,transmitters
have 0 ~ 9 grades switch which
used for dial the code for your choose
Match with E and R motors:
emitter should be already programmed.If emitter
is delete,then the wind-sun sensor is invalid
press the muti-function
button one times of
DC510
The dial switch
is adjusted to 0
Match with DC136
press the muti-function
button one times of
DC510
The dial switch
is adjusted to 5
batteries
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
FCC Warning:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
MODIFICATION: Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate
the device.