1 - GENERAL WARNINGS
- Important safety instructions. It is important that you
comply with these instructions to ensure your safety. Keep
these instructions. • Handle the product with care so as to
prevent crushing, knocks, falls or contact with liquids of any kind.
Keep the product away from sources of heat and open ames.
Failure to observe the above can damage the product and incre-
ase the risk of danger or malfunctions. • Do not carry out any
operations on the product other than those described in this
manual and in the manuals of the other components provided in
the system. • Packaging materials must be disposed of in accor-
dance with local regulations.
2 -
PRODUCT DESCRIPTION AND INTENDED USE
The DMBDI/U (DIN Module Radio Receiver) is a module of the
“Nice Modular System” which is used, along with other mod-
ules of the same system, to assemble “modular” control units
with custom and advanced features. Each obtained control unit
is intended for programming and controlling the Nice actuators
and/or motors, which are controlled via wiring or radio and used
to automate various applications installed in the “Home, Hotel,
Commercial Building and Industrial Building” sectors. For further
information on the “Nice Modular System” consult the in-
struction manual of the DMBPD module.
The presence of the DMBDI/U inside a control unit is optional and
at the discretion of the installer, depending on the requirements of
the automation to be created. The DMBDI/U adds to the control
unit the radio receiver function between the “Nice Modular Sys-
tem” control unit, the motors and Nice actuators.
Note - The pack only contains the DMBDI/U module.
- The DMBDI/U only works if connected to other essential
components of the “Nice Modular System”, in the manner de-
scribed herein and in the manual of the DMBPD module. Any
use other than that described is regarded as improper and
is forbidden! The manufacturer is not liable for damages
resulting from improper use of the product.
Description of LED signals on the module:
LED L1: LED signal light 1
LED L2: LED signal light 2
LED SERVICE: the device is switched on and functions correctly
3 - INSTALLATION AND HOOK-UP OF THE MODULES
Warnings: All installation and connection operations must be
carried out in the absence of mains electrical power and must be
performed by qualified technical personnel in full compliance with
the law, electricity regulations and applicable safety standards.
• Include a disconnection device (not supplied) in the system’s
mains power supply between the electricity line and power supply
module, with a contact opening distance that ensures complete
disconnection under the conditions envisaged by Overvoltage
Category III. • Strictly observe all the connection instructions: in
-
correct connection can cause faults or dangerous situations. • It
is forbidden to install the modules outdoors.
All modules included in the “Nice Modular System” must be in-
stalled inside an electrical panel, positioned one after the other
and hooked to one or more DIN rails (example in Fig. 1)
- The modules must be hooked to the DIN rail in one
direction only: if they are connected together incorrectly,
outside the DIN rail, then powered, they may be damaged
beyond repair.
- WARNING: the modules must be connected to each
other ONLY when they ARE NOT powered.
4 - PROGRAMMING OF THE MODULAR CONTROL UNIT
After having installed and connected the DMBDI/U module to-
gether with the other modules of the system, it is possible to ac-
quire a transmitter in the module and combine one or more Out-
puts present on the modular control unit; for the other modules
refer to the respective instruction manual.
Up to maximum 30 channels can be memorised, with 16 outputs
each memorisable.
5 - MODULE PROGRAMMING
The programming procedures are described below and must be
carried out with one transmitter of the “Era P” and “Era W” series.
- Prior to starting, select the desired channel and main-
tain it throughout the procedure.
- In the procedures described below, two different icons
are used for the ‘PROG’ key:
PRG
= module key
PRG
= transmitter key
When programming while pressing the key for an extended time
(longer than 1 second), release the key being pressed as soon as
the L1 LED starts flashing.
- The ESC key (on the transmitter) is used to exit from
any programming step (LED L1 flashes 6 times).
6 - DISPOSAL OF THE PRODUCT
This product is an integral part of the automation in which it will be
installed and must therefore be disposed of together with it, in the
manner indicated in the automation’s instruction manual.
7 - TECHNICAL SPECIFICATIONS
Note • All technical specifications stated herein refer to an ambi
-
ent temperature of 20°C (± 5°C). • Nice S.p.A. reserves the right
to apply modifications to products at any time when deemed nec-
essary, maintaining the same intended use and functionality.
- The DIN rails must have the characteristics shown in
Fig. 3.
Power supply: 24V from the internal bus. • Maximum power
consumption: 30mA (0.72W). • Signals: 3 diagnostic LEDs.
Inputs: maximum 30 memorisable channels, with 16 outputs
each memorisable. • Radio coding: F-Code (rolling code). • Pro-
tection rating: IP 20. • Overall dimensions of the module on
the DIN rail: 2 units. • Dimensions: 35 x 90 x 60 mm. • Weight:
65 g.
8 - COMPLIANCE WITH THE FCC RULES (PART 15)
AND RSS-210 RULES
This device complies with Industry Canada’s licence-exempt RSS-
210s, and with Part 15 of the FCC rules of the United States of
America. Operation is subject to the following two conditions:
1) this device may not cause interference;
2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Any changes or modifications made to this device, without the
express permission of the manufacturer, may void the user’s au
-
thority to operate this device.
This radio transmitter (identify the device by certification num-
ber) has been approved by Industry Canada to operate with the
antenna types listed below with the maximum permissible gain
indicated. Antenna types not included in this list, having a gain
greater than the maximum gain indicated for that type, are strictly
prohibited for use with this device.
antenna type: 6083F00002, Gain < 1dBi
MEMORISATION OF A TRANSMITTER
01.
= 7 s
L2
memory open
02.
x 3
PRG
1 s
03.
= 1 s
L1
L1
memorisation conrmation
Note: if L1 flashes 6 times, it means that the memory is
full or it is locked; therefore, it is not possible to memorise
other transmitters. At least one must be deleted or unlock
the memory.
TABLE A
ADDING or REMOVING a combination between the transmitter ALREADY MEMORISED and motors/outputs
Note - This procedure can also be performed through the “Nice Screen Conguration Tool” of the DMBM module (if included in the control unit).
01.
ACCESS the procedure “Select Output” to add or remove a combination, making reference to the instruction
manual of the relevant motor or module
02.a
ADDING a transmitter
02.b
REMOVING a transmitter
press
s 3 times
on the desired transmitter
L1
L1
press in sequence
s, t, s on the transmit-
ter to be removed
L1
L1
03.
EXIT the procedure “Select Output” to add or remove a combination, making reference to the instruction manual
of the relevant motor or module
To associate other Inputs/Outputs, repeat the procedure from step 01.
COPYING A TRANSMITTER or ADDING A CLIMATE SENSOR
01.
= 10 s
P1
of the new
transmitter or
of the climate
sensor
P1
L1
L1
memory open
02.
1 s
1 s
1 s
of the OLD transmitter
03.
= 5 s
P1
of the new
transmitter or
of the climate
sensor
P1
L1
L1
memorisation conrmation
Note: if L1 ashes 6 times it means that
the memory is full and, therefore, it is not
possible to memorise other transmitters. At
least one of them must be deleted.
LOCKING / RELEASING THE MEMORY
01. 02. 03. 04. 05.
Lock memory
1 s
1 s
1 s
1 s
1 s
1 s
3 s
5 s
L1
L1
05.
Release memory
L1
L1
L1
L1
L1
5 s
L1
L1
ASSIGN THE DIN BUS ADDRESS
(to be done only if multiple modules are used in the
same modular control unit)
01. 02. 03.
1 s
1 s
= 5 s
of the transmitter
L1
L1
L1
L1
L1
04.
SELECT the relevant address among the following
options:
1 press = address 13
(FACTORY SETTING)
2 presses = address 14
= 1 s
3 presses = address 15
4 presses = address 16
5 presses = automatic ADDRESS-
ING from the DMBM module
05.
5 s
L1
L1
on the relevant channel to conrm the memorisation: after hav-
ing observed the number of ashes corresponding to the num-
ber of presses performed
DELETE ALL TRANSMITTERS
(possible with any memorised transmitter)
01.
1 s
L1
02.
1 s
L1
03.
1 s
L1
L1
04.
1 s
L1
L1
05.
= 3 s
L1
L1
DELETE A SINGLE TRANSMITTER
01.
1 s
L1
02.
1 s
L1
03.
1 s
L1
L1
04.
1 s
L1
L1
05.
3 s
3 s
L1
L1
06.
3 s
Press the STOP key on the transmitter
to be deleted until the module flashes
5 times
TOTAL DELETION
(restoration of factory settings)
(possible with any memorised transmitter)
01.
1 s
L1
02.
1 s
L1
03.
1 s
L1
L1
04.
1 s
L1
L1
05.
1 s
L1
L1
ASSOCIATE TRANSMITTER KEY WITH A FUNCTION
01. 02.
1
s
transmitter channel already memorised
= 5 s
= 3
s
L1
L1
L1
L1
the levels P1...P7 are stored in the motor
03.
SELECT the desired level among the following op-
tions:
1 press = level P1
L1
L1
2 presses = level P2
L1
1 s
10 s
3 presses = level P3
L1
L1
4 presses = level P4
L1
L1
5 presses = level P5
L1
L1
1 press = level P6
L1
L1
2 presses = level P7
L1
10 s
1 s
3 presses = s (position
of the upper limit switch)
L1
L1
4 presses = n (associ-
ates the STOP function)
L1
L1
5 presses = t (position
of the lower limit switch)
L1
L1
04.
5 s
3 s
L1
L1
on the relevant channel to conrm the memorisation: after hav-
ing observed the number of ashes corresponding to the num-
ber of presses performed
05.
= 5 s
= 3 s
L1
L1
on the same transmitter or any button of the NEW transmitter
1 mm
7,5 mm
35 mm
27 mm
1
2
3
7
UP COM
MOTOR A
DW
8 9 10 11 12
UP COM
MOTOR B
DW
y Contact Inputs
1
UP GND
A
DW
2 3 4 5 6
UP GND
7
UP COM
MOTOR A
DW
8 9 10 11 12
UP COM
MOTOR B
DW
y Contact Inputs
1
UP GND
A
DW
2 3 4 5 6
UP GND
7
UP COM
MOTOR A
DW
8 9 10 11 12
UP COM
MOTOR B
DW
y Contact Inputs
1
UP GND
A
DW
2 3 4 5 6
UP GND
DMBPD DMBPD DMBPD
+
bus
24V
POWER
SUPPLY
ac
+
+
+–NL
DM(...)
DMBD
DM(...) DM(...)
DM(...)
DM(...)
DM(...)
DM(...)
bus
bus
123
123
45
6
-+
ON
24V

Summary of content (2 pages)