Model:R718Y Wireless Differential Pressure and Temperature sensor Wireless Differential Pressure and Temperature sensor R718Y User Manual Copyright© Netvox Technology Co., Ltd. This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
Table of Content 1. Introduction ..................................................................................................................................... 3 2. Appearance ...................................................................................................................................... 4 3. Main Features .................................................................................................................................. 4 4. Set up Instruction.....................
1. Introduction R718Y is the Class A device based on the LoRaWANTM protocol of Netvox. The device detects the pressure difference and the temperature. It is compatible with the LoRaWAN protocol. LoRa Wireless Technology: LoRa is a wireless communication technology dedicated to long distance and low power consumption. Compared with other communication methods, LoRa spread spectrum modulation method greatly increases to expand the communication distance.
2. Appearance Indicator Function Key 3. Main Features ⚫ Apply SX1276 wireless communication module ⚫ 2 ER14505 batteries AA size (3.
4. Set up Instruction On/Off Power on Insert batteries. (The users may need a screwdriver to open.) Turn on Press and hold the function key for 3 seconds till the green indicator flashes once. Turn off (Restore to factory setting) Press and hold the function key for 5 second, and the green indicator flashes 20 times. Power off Remove Batteries. 1. Remove and insert the battery; the device is at off state by default. 2.
5. Data Report When the device is powered on, it will immediately send a version package Report and the report data with the device battery voltage, the differential pressure, and the temperature. The device sends data in the default configuration before any configuration is done. Default setting: MaxTime: Max Interval = 15 min = 900s MinTime: Max Interval = 15 min = 900s BatteryChange = 0x01 (Unit: 0.1v) Different Pressure Change = 0x0A (1 Pa) (Unit: 0.1Pa) Temperature Change = 0x0A (1°C) (Unit: 0.
Device Device CmdID NetvoxPayLoadData Type R718Y 0xAC Battery Different Pressure Temperature (1byte, Unit: 0.1v) (Signed2Bytes, Unit: 0.1Pa) (Signed2Bytes,Unit:0.1°C) 0x01 Reserved (3Bytes, Fixed 0x00) Uplink: 01AC0124001E0116000000 1st byte (01): Version 2nd byte(AC): DeviceType 0xAC - R718Y 3rd byte (01): ReportType 4th byte (24): Battery, 24 Hex=36 Dec 36*0.1v=3.6v 5th 6th byte (001E): Different Pressure, 1E Hex =30 Dec 30*0.1Pa=3 Pa 7th 8th byte (0116): Temperature, 116 Hex =278 Dec 278*0.
1AC010000000000000000 (configuration failed) (2) Read device parameters Downlink: 02AC000000000000000000 Device returns: 82AC003C003C0100640064 (current device parameters) 5.3 Example for MinTime/MaxTime logic Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V MaxTime MaxTime Sleeping(MinTime) Sleeping(MinTime) Wakes up and collects data Wakes up and collects data Wake up and collects data REPORTS 3.6V REPORTS 3.6V REPORTS 3.
Notes: 1) The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not collect data. 2) The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value, the device reports according to MinTime interval. If the data variation is not greater than the last data reported, the device reports according to MaxTime interval. 3) We do not recommend to set the MinTime Interval value too low.
7. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: • Keep the device dry. Rain, moisture, or any liquid might contain minerals and thus corrode electronic circuits. If the device gets wet, please dry it completely. • Do not use or store the device in dusty or dirty environment. It might damage its detachable parts and electronic components. • Do not store the device under excessive heat condition.
FCC Statement: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.