Certification Exhibit FCC ID: P2SNTR900GDL IC: 4171B-NTR900GDL FCC Rule Part: 15.247; 15.249 IC Radio Standards Specification: RSS-210 ACS Report Number: 10-0053.W06 Manufacturer: Neptune Technology Group, Inc. Model: R900GDL Manual 5015 B.U.
E-Cod ARB UTILITY MANAGEMENT SYSTEMS WATER | ELECTRIC | GAS R 9 0 0 G E N D P O I N T I N S TA L L AT I O N A N D M A I N T E N A N C E G U I D E R900G Endpoint Installation and Maintenance Guide
ARB UTILITY MANAGEMENT SYSTEMS WATER | ELECTRIC | GAS R900G ™ Endpoint Installation and Maintenance Guide
This manual is an unpublished work and contains the trade secrets and confidential information of Neptune Technology Group Inc., which are not to be divulged to third parties and may not be reproduced or transmitted in whole or part, in any form or by any means, electronic or mechanical for any purpose, without the express written permission of Neptune Technology Group Inc. All rights to designs or inventions disclosed herein, including the right to manufacture, are reserved to Neptune Technology Group Inc.
Industry Canada This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l'interférence canadienne causant des règlements d'équipement.
Contents 1 Product Description R900G Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 RF Protocol Error Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 RF Frequency Control Algorithm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 RF Transmission Period and Randomness . .
Contents 5 Programming the R900G Endpoint Starting the R900G Programmer Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figures Figure 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Title Page AC250 with R900G Endpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Sensus R-275 with R900G Endpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 R900G MIU Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figures Notes: viii R900G Endpoint Installation and Maintenance Guide
Tables Table 1 2 3 Title Page Identification Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Recommended Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Recommended Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figures Notes: x R900G Endpoint Installation and Maintenance Guide
1 Product Description This section provides a general description of the R900G Endpoint for various natural gas meters that provide meter consumption and value-added data. The Neptune R900G Endpoint combines the field-proven R900® radio frequency (RF) technology, developed by Neptune Technology Group, into a retrofit module for current residential and commercial natural gas meters from American, Equimeter (Sensus/Rockwell), and Actaris (Sprague).
Product Description R900G Programming The R900G is field-programmable via an Infrared (IR) port. At the factory, each of the following items is programmed into the MIU: • Serial number - Each R900G module is given a unique serial number/identification number. To eliminate the possibility for duplicate ID numbers, custom serial numbers are not available. • Time between meter readings - The R900G module updates the meter reading every 15 minutes.
Product Description R900G Endpoint Value-Added Features (continued) Magnetic Tamper The R900G has the capability of detecting the use of a large outside magnetic field (capable of saturating sensors) being brought near the shaft sensor. If this occurs, the magnetic tamper flag displays. Reverse Flow Tamper The R900G has the capability of detecting reverse rotation of the meter output shaft. If such a tamper occurs, the volume increments in the normal fashion, and the reverse-flow tamper flag displays.
2 Specifications This section provides you with the specifications for the R900G Endpoint. Electrical Specifications Power Lithium battery with Hybrid Layer Capacitor (HLC) Capacitor Transmitter Specifications Transmit Period Every 14 seconds Transmitter Channels 50 Channel Frequency 902-928 MHz Output Power Meets FCC Part 15.247 FCC Verification Part 15.
Specifications Specifications - R900G MIU Environmental Specifications Operating Temperature -22° to 149°F (-30° to 65°C) Storage Temperature -40° to 158°F (-40° to 70°C) Operating Humidity 0 to 95% Condensing Functional Specifications MIU ID 10 digits Dimensions and Weight Dimensions Refer to Figure 3 Weight 1.0 lbs.
Specifications Meter Compatibility The following table represents all current residential and topmount commercial American, Sensus, Equimeter, and Actaris models.
3 General Installation Guidelines This section describes tools, materials, and general installation information for the R900G Endpoint. Product Unpacking and Inspection Upon receipt of the product, the following unpacking and inspection procedures should be performed. If damage to the shipping container is evident upon receipt, request the carrier to be present when the product is unpacked. Carefully open the shipping container, follow any instructions that may be marked on the exterior.
General Installation Guidelines Tools and Materials Tables 2 and 3 show the recommended tools and materials you may need to successfully install the R900 MIU or to replace the MIU’s internal battery. Some items may not apply to your specific installation or the list may not contain all required tools or materials.
4 R900G Endpoint - Retrofit Installation Before proceeding with the installation, make sure the R900G Endpoint number matches model required for the specific gas meter model being installed. Refer to Table Table 1 on page 6. Complete the following instructions to install an R900G Endpoint according to the model required for the specific gas meter you are installing.
R900G Endpoint - Retrofit Installation Removing the Index Tamper Plugs Complete the following steps for index removal. 1 Use a large, flat head screwdriver to puncture and remove existing Tamper Plugs, if present. (See Figure 5.) 2 Use a large screwdriver to remove and discard the four lens mounting screws and the lens. (See Figure 6.) 3 Remove the gasket. Use a putty knife to remove any excess gasket from the meter body casing. 4 Use a small screwdriver to remove the two index mounting screws.
R900G Endpoint - Retrofit Installation Installing the Index and the R900G Endpoint Complete the following steps to install the Index and the R900G Endpoint to the meter body casing. 1 Place the gas meter index on the front of the R900G Endpoint ensuring that the two drive dogs are aligned for engagement. (See Figure 8.) 2 Secure the index to the R900G housing using the 2 index mounting screws removed from the meter in Step 4 during “Removing the Index” on page 10. (See Figure 7 and Figure 9.
R900G Endpoint - Retrofit Installation 4 Slide the cover over the R900G Endpoint housing. 5 Use the four mounting screws (supplied) to secure the cover and the R900G Endpoint to the gas meter casing. (See Figure 11.) 6 Install two tamper snap seals (supplied) into the recess in the cover. 7 Seat firmly.
R900G Endpoint - Retrofit Installation Removing the Index Complete the following steps for index removal. 1 Use a large, flat head screwdriver to puncture and remove existing tamper plugs, if present. (See Figure 13.) 2 Use a large screwdriver to remove and discard the four lens mounting screws and the lens. (See Figure 14.) 3 Remove Index Screws remove the two index mounting screws. Do not discard these screws as they are needed to mount the existing index to the R900G housing. (See Figure 15.
R900G Endpoint - Retrofit Installation Install the Index and the R900G Endpoint. 4 Place the gas meter index on the front of the R900G Endpoint ensuring that the two drive dogs are aligned for engagement.(See Figure 16.) 5 Secure the index to the R900G housing using the 2 index mounting screws removed from the meter in Step 3 during “Removing the Index” on page 10. (See Figure 15 and Figure 17.
R900G Endpoint - Retrofit Installation 7 Slide the cover over the R900G Endpoint housing. 8 Use the four mounting screws (supplied) to secure the cover and the R900G Endpoint to the gas meter casing. (See Figure 19.) 9 Install two tamper plugs (supplied) into the recess in the cover. 10 Seat firmly.
5 Programming the R900G Endpoint To program an R900G Endpoint, use the Neptune CE5320X handheld with Equinox software to display and process the information. Figure 20 Neptune CE5320X Handheld with Field Programmer Starting the R900G Programmer Software 1 Start the R900G Programmer Software by completing the following steps from the Equinox Start Screen. See Figure 21. 2 While on the Equinox main screen, touch .
Programming the R900G Endpoint The Equinox main menu appear as illustrated in Figure 22. 3 Select Admin. . Figure 22 Equinox Menu The Equinox Admin menu appears as illustrated in Figure 23. 4 Select Exit. Figure 23 Equinox Administrator Menu The Administrator Password screen appears as illustrated in Figure 24. 5 When prompted, type in the password provided by your company, such as, BUBBA. 6 Touch .
Programming the R900G Endpoint The screen backlight will turn off. Press screen backlight. 7 F3 to turn on the Tap the screen once. The Folder selection screen appears as illustrated in Figure 25. Figure 25 Folder Selection Screen 8 Select My Documents. The R900G Programming icon appears as illustrated in Figure 26. 9 Select . Figure 26 R900G Programming Icon When the programming software begins, the screen illustrated in Figure 27 appears.
Programming the R900G Endpoint 11 Make the following selections on this window: • From the Meter Make drop-down selection list, choose the appropriate setting for the type of meter to program. • From the Pressure drop-down selection list, choose the appropriate setting for the pressure compensation. • From the Test Hand drop-down selection list, choose the appropriate resolution. • For the Initial Reading, type the index reading, for example, 2345.
Programming the R900G Endpoint Contact Information Within North America, Neptune Support is available Monday through Friday, 8:00 AM to 7:00 PM Eastern Standard Time, by telephone or fax. To contact Technical Support by phone, call 1-800-645-1892. If all Support Technicians are helping other customers, your call will be routed to the Neptune Support voice mail system. Please leave your name, the name of your company, and your telephone number.
Index dimensions 5 drive dogs American A accessories, meter 7 Actaris gas meter models 6 algorithm randomness 2 RF frequency control 2 American dial index 9, 12 drive dog 11, 14 drive dogs 11 gas meter models 6 index removal 10, 13 index removed 10, 13, 15 odometer index 9, 12 R900G housing 10, 13 11, 14 E electrical specifications 4 environmental conditions 5 Equimeter, models 6 Equinox main menu 17 main screen 16 F FCC battery internal 8 lithium 4 notice ii verification 4 features, value-added 2 fie
Index interférence canadienne iii Invensys, models 6 IR programming device 8 serial number 2 specifications 4 tools and materials 8 weight 5 R900G (illus.) 1 R900G housing American 10, 13 R900G Programming 18 radio technology 1 readings 2 reads, success rates 2 receiver, for programming 8 regulations, Canadian iii retrofit installation 9 RF exposure information ii frequency 2 module 1 protocol, error detection technology 1 transmission 2 Rockwell models 6 M main menu.
Index transmission randomness 2 RF 2 Transmitter specifications 4 V verification, FCC 4 W U unpacking the product 7 R900G Endpoint Installation and Maintenance Guide weight, R900G 5 work order, site 8 23
Index Notes: 24 R900G Endpoint Installation and Maintenance Guide
Neptune Technology Group Inc. 1600 Alabama Highway 229 Tallassee, AL 36078 USA Tel: (334) 283-6555 Fax: (334) 283-7299 Neptune Technology Group (Canada) Ltd. 7275 West Credit Avenue Mississauga, Ontario L5N 5M9 Canada Tel: (905) 858-4211 Fax: (905) 858-0428 IM R900G 06.07 Part No. 12778-001 © Copyright 2006 -2007, Neptune Technology Group Inc. Neptune Technology Group Inc. Ejército Nacional No. 418 Piso 12, Desp. 1201-1202 Col.