Repeater User Manual Model:NAS-RP01Z1U (S2 Version) Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for further reference This product can be included and operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Operation configuration Specifications Power Supply Power Consumption Operational Temperature Communication frequency 85 – 240V AC, 50/60Hz Up to 0.8W 0 - 40℃ 908.40MHz, 916.00MHz(US) Range Up to 80m indoors (depending on the building structure) Up to 100m outdoors. Detect temperature range -20~80℃ Compatible with any Z-Wave main controller. The use distance of the equipment can be increased by repeater, and the distance can be increased by up to 100 m.
Press and hold the button for 5s until Green led lights is on, then release the Send NIF³ button before green led turn off. Notice 1: When device enters into inclusion mode, the device all functionality will be useless. The inclusion mode will be timeout after 30s, user can press and hold the button for 5s to terminate inclusion mode.
Device Functionality and Z-Wave™ Message Report This device has two main functions: repeater and ambient temperature and humidity measured. Repeater This device is a z-wave repeater device. In the z-wave network, it can be as a router to extend the communication distance. Temperature and humidity monitor The device have embeds a temperature and humidity sensor to monitor ambient temperature and humidity variation and report to z-wave hubs.
1)When sensor enters to measure mode, this setting decides the Led indicated or not. ‘0’ – No led blinks. ‘1’ – led blinks with red. Parameter Number Size (Byte) Available Settings Default value 1 1 0, 1 1 2) OTA Led Disable When OTA is running, this setting decides the Led blinking or not. ‘0’ – No Led blinks. ‘1’ – Led blinks with yellow.
alarm through the device associated in group 3. The Alarm Value = [Value] × 0.1 Degree Celsius / Fahrenheit (US). Parameter Number Size (Byte) Available Settings 8 2 -200 ~ 600 Default value 300 9) Low Humidity Alarm Value This parameter is configured the threshold value that alarm level for low humidity. When the current ambient humidity value is less than this configuration value, device will trigger an alarm through the device associated in group 4. The Alarm Value = [Value] × 0.1 RH%.
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. This device supports SmartStart function. QR code is printed on the label that pasted on on surface of product and the outside of packing box.
COMMAND_CLASS_TRANSPORT_SERVICE 2 ● ● ● ● COMMAND_CLASS_VERSION 3 ● ● ● ● COMMAND_CLASS_POWERLEVEL 1 ● ● ● ● COMMAND_CLASS_ASSOCIATION 2 ● ● ● ● COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION 3 ● ● ● ● COMMAND_CLASS_ASSOCIATION_GRP_INFO 1 ● ● ● ● COMMAND_CLASS_MANUFACTURER_SPECIFIC 2 ● ● COMMAND_CLASS_DEVICE_RESET_LOCALLY 1 ● ● ● ● COMMAND_CLASS_SENSOR_MULTILEVEL 11 ● ● ● ● COMMAND_CLASS_INDICATOR 3 ● ● ● ● COMMAND_CLASS_CONFIGURATION 4 ● ● ● ● COMMAN
FCC STATEMENT : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.