User's Manual

Installation Steps
1. Holder Installation
3. Fix water sensor on the holder
Open the water sensor Install the battery Close the water sensor
2. Battery Installation
NOTE:
1. When assembling the water sensor, please align the assembly mark.
the induction contact.
4.Probe installation
With the detection cable, the detection range can be extended.
Product Introduction
Water sensor is an intelligent security equipment that can
transmit the Z-Wave network which has particular frequency.
Dierent countries or areas, the radio frequency of Z-Wave is
dierent. In the Z-Wave network communications, water sensor
can work with any Z-Wave main controller. In the Z-Wave
network communications, water sensor can send messages to
the Z-Wave main controller, and realize association with other
devices through the Z-Wave network. In the communication
with the Z-Wave main controller, the water sensor can send
messages to the Z-Wave main controller, but it can not receive
messages from the Z-Wave main controller. When the water
sensor is triggered, the LED light keeps on and the buzzer will
make sound. The water sensor sends messages to the Z-Wave
main controller at the same time, the Z-Wave main controller
will display the current status of water sensor. Water sensor is
battery powered, is small and can be installed easily.
Technical Parameters
Flood detection
Battery specication: CR2-3V x 1
Standby current: 3uA
Max current: 35 mA(In Radio Transmitter MODEL)
Battery life: 2 years
Radio Protocol: Z-Wave
Radio Frequency: 868.4MHz EU;908.4MHz US
Range: up to 80m outdoor;up to 40m indoor
Operation temper: 0-40
Storage temperature: 0-60
Size (D x W x H): 68mm x 68mm x 34mm
Technical Information
When alarm triggered, LED light ashes in the detection area.
Easily install with screws or sticker .
Detecting the location of the overow timely and accurately ,
reduce the economic losses caused by the overow of water.
Compatible with any Z-Wave main controller.
High sensitivity and good stability.
Product Conguration
What’s in the box ?
Water sensor 1pc
Holder 1pc
Battery 1pc
Screw 2pcs
Screw stopper 2pcs
Probe 1pc
User manual 1pc
LED Color Indicator
Advanced CongurationAssociationsNetwork Conguration
Add Water Sensor to Z-Wave Network
The water sensor can be included to the Z-Wave network by
pressing the code button.
1. Disassemble the water sensor and insert the battery into the
water sensor. Make sure the device locates within the network
of the Z-Wave main controller.
2. Set the Z-Wave main controller into the learning mode (see
main controller's operating manual).
3. Quickly, triple click the code button, LED light ashes red for
5 times.
4. Water sensor will be detected and included in the Z-Wave
network.
5. Wait for the main controller to congure the water sensor.
Note:Power to the code, the device is plugged into the power 20S can not have
any operation!
Remove Water Sensor from Z-Wave Network
1. Make sure the sensor is connected to power source.
This Sensor supports 4 association groups. Each group supports
max 5 associated nodes.
This has the eect that when the sensor is triggered, all devices
associated with the sensor will receive the relevant reports.
Through an association the sensor may control another Z-Wave
network device, e.g. siren device, wall plug, lamp etc.
GROUP 1 is lifeline service that assigned to Sensor (Water
leakage detector) status. It enables the sensor to send reports
and readings to Z-Wave Controller or Z-Wave Gateway
whenever the sensor is triggered. This Group Support:
NOTIFICATION_REPORT_V4,BATTERY_REPORT,
SENSOR_BINARY_REPORT_V2,DEVICE_RESET_LOCALLY_NOTIFI
CATION
GROUP 2 allows for sending control commands to associated
devices such as relay module, lighting, etc. This association
group is congured through the advanced parameters no. 7. If
the sensor clears the Notication Event that a Basic Set with
1. Conguring Alarm Duration Time
This conguration parameter that can be used to adjust the time for beep and
LED turned on when water leakage is detected. If this parameter is set to ‘0’, the
beep and LED will be turn on always until water leakage is not detected. Prefer
to Figure 1.
Parameter Number: 1
Parameter Size: 1
Available Settings: 0-255min
Default Setting: 120min
2. Congure Alarm Interval
This Parameter denes beep on /o interval time when water leakage is
1. Make sure the water sensor is in the Z-Wave main controllers
network.
2. Do not install in the place near water vapor or smoke.
3. Do not install the water sensor main body and the probe in the
place where water is soaked.
4. The sensor probe should be placed on the surface of the water
leakage.
5. Direct association is allowed between water sensor and other Z-
wave network devices if preset association functionality. Z wave
gateway does not take part in such communication. Using this
mechanism, water sensor can communicate with other devices even
when gateway is damaged.
Tips
01 02 03 04 05 06 07
11 12 13 14 151009
2. Set the Z-Wave main controller into the learning mode (see
main controller's operating manual).
3. Quickly, triple click the code button, LED light ashes red for 5
times.
4. Wait for the Z-Wave main controller to delete the sensor.
Restore the Water Sensor to Factory Default Settings
Reset procedure will delete all information on the Z-Wave
network and Z-Wave controller, and restore the sensor to
factory default settings.
1. Remove the device cover.
2. Make sure the water sensor is connected to power source.
3. Press the reset button for 10 seconds, LED light ashes red for
1 times.
4. Release the button.
Note:When the water sensor is being restored factory settings, please make sure
power source is connected.
Wakeup the Sensor Manual
User can press button once to wake‐up this sensor to send
wakeup notication to controller, the Led will be blink one time.
detected.Prefer to Figure 1.
Parameter Number: 2
Parameter Size: 1
Available Settings: 1 – 255min.
Default Setting: 1min
3. Congure First Alarm On Time Duration
This parameter denes beep on duration rst time when water leakage is
detected.Prefer to Figure 1.
Parameter Number: 3
Parameter Size: 1
Available Settings: 1 – 255s
Default Setting: 60s
4. Congure Alarm on Time Duration
This parameter denes beep on duration after st beep on when water leakage
is detected. Prefer to Figure 1.
Parameter Number: 4
Parameter Size: 1
Available Settings: 5-255s
Default Setting: 5s
5. Congure Alarm Enable/Disable
This parameter denes beep on is enabled or disabled when water leakage is
detected. ‘0’ indicate beep on is disable, but LED will be turned on when water
leakage detected. ‘1’ indicate beep on is enabled, the BEEP and LED will be
turned on when water leakage detected.
Parameter Number: 5
Parameter Size: 1
Available Settings: 0,1
Default Setting: 1
6. Congure Water Leakage Detected Enable/Disable
This parameter denes the function than water leakage detect is enabled or
disabled. ‘0’ indicate disable water leakage detect, ‘1’ indicate enable water
leakage detect.
Parameter Number: 6
Parameter Size: 1
Available Settings: 0,1
Default Setting: 1
7. Basic Set Level
Basic Set Command will be sent where contains a value when the door/window
is opened or closed, the receiver will take it for consideration; for instance, if a
lamp module is received the Basic Set Command of which value is decisive as to
how bright of dim level of lamp module shall be.
Command: SENSOR_BINARY_REPORT
Sensor Type: SENSOR_DOOR_WINDOW
Value:0x00
Parameter Number: 7
Parameter Size: 1
Available Settings: 0-99,255
Default Setting: 255
Fix the holder with screws and screw stopper
07
16
0x00 is sent to the nodes associated in Group 2 in order to turn
o the device. This Group Support:BASIC_SET.
GROUP 3 allows for Send Notication to associated devices in
this group. This Group Support:NOTIFICATION_REPORT_V4
GROUP 4 allows for Send Notication to associated devices in
this group. This Group Support:SENSOR_BINARY_REPORT_V2
08
LED Color
Led Display Status
Description
Red
Blink 5 Times
(1s Interval)
Power on and Not Add in Z-Wave
Network
Blink 5 Times
(500ms Interval)
Press Button tripled, Adding siren in a
Z-Wave Network or Send Node Info.
Blink 5 Times
(300ms Interval)
Power on and Already Add in a Z-Wave
Network
Blink 1 Time
Press the Button Long Time, Reset the
Plug torestore default settings;
Blink with Beep
On/O
Detect water leakage
This Sensor supports Command Classes as Below:
* COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
* COMMAND_CLASS_VERSION (V2)
* COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
* COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
* COMMAND_CLASS_POWERLEVEL (V1)
* COMMAND_CLASS_BATTERY (V1)
* COMMAND_CLASS_ASSOCIATION (V2)
* COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)
* COMMAND_CLASS_WAKE_UP (V2)
* COMMAND_CLASS_NOTIFICATION (V4)
* COMMAND_CLASS_SENSOR_BINARY (V2)
* COMMAND_CLASS_CONFIGURATION (V1)
Command Classes
16
Notication Command Class
Once the detector detected a water leakage, it will send
NOTIFICATION_REPORT and SENSOR_BINARY_REPORT to the nodes of lifeline
to inform there is a water leakage event. When water leakage is not detected,
NOTIFICATION_REPORT and SENSOR_BINARY_REPORT will be sent again to the
nodes in lifeline.
For compliant to Z-Wave 300 Series, There also realize the Binary Sensor
Command Class.
Notication Report Command:
Event Present:
Command Class: COMMAND_CLASS_NOTIFICATION
Command: NOTIFICATION_REPORT
Notication Type: NOTIFICATION_TYPE_WATER_ALARM
Event:NOTIFICATION_EVENT_WATER_ALARM_WATER_LEAK_DETECTED_UNKN
OWN_LOCATION
Event Clear:
Command Class: COMMAND_CLASS_NOTIFICATION,
Command: NOTIFICATION_REPORT,
Notication Type: NOTIFICATION_TYPE_WATER_ALARM,
Event:NOTIFICATION_EVENT_WATER_ALARM_NO_EVENT
Binary Sensor Report Command:
Event Present:
Command Class: COMMAND_CLASS_SENSOR_BINARY
Command: SENSOR_BINARY_REPORT
Sensor Type: SENSOR_WATER
Value: 0xFF
Event Clear:
Command Class: COMMAND_CLASS_SENSOR_BINARY
Command: SENSOR_BINARY_REPORT
Sensor Type: SENSOR_WATER
Value: 0x00
Battery Check Command
The users can also enquire the battery status of the water detector by sending
BATTERY_GET command. Once the water detector receivers the command, it
will return BATTERY_REPORT command. The water detector will send
BATTERY_LEVEL = 0xFF command to the Z‐Wave Controller to inform that the
water detector is in dead battery status, otherwise BATTERY_LEVEL value range
is 0% to 100%.
Wakeup Command Class
The water detector stays in sleep status for the majority of time in order to
conserve battery life. The minimum wakeup interval is 300s
The maximum wakeup interval is 16,777,200s (about 194 days)
Allowable interval among each wakeup interval is 60 second, such as 360, 420,
480…
Note: The default value is 12 hours. This value is longer, the battery life is
greater.
Assembly mark
LED light
The Code button
Battery
Buzzer
Induction contact
Holder
Probe interface
Induction foot
Screw
Screw stopper
1
2
3
User Manual
Thank you for your support
Please read the user manual carefully before operating.
Please keep the user manual for future reference.
Water Sensor
1.The Guarantee is provided by our company (hereinafter “Manufacture )
2.The Manufacturer is responsible for equipment malfunction resulting from
physical defects (manufacturing or material) for 12 months from the date of its
purchasing.
3.During the Guarantee period, the Manufacturer shall repair or replace any
defects, free of charge.
4.In special cases, when the device cannot be r
same type (e.g. the device is no longer available in the commercial oer), the
Manufacturer may replace it with a dierent device which has similar technical
parameters as the faulty one. Such activity shall be considered as fullling the
obligations of the Manufacturer. The Manufacturer shall not refund money paid
for the device.
5.The guarantee shall not cover:
a. mechanical damages (cracks, fractures, cuts, abrasions, physical
deformations caused by impact, falling or dropping the device or other object,
improper use or not observing the operating manual);
b. damages resulting from external causes, e.g.: ood, storm, re, lightning,
natural disasters, earthquakes, war, civil disturbance, force majeure, unforeseen
accidents, theft, water damage, liquid leakage ,battery spill, weather conditions,
sunlight, sand, moisture, high or low temperature, air pollution
c. damages caused by malfunctioning software, attack of a computer virus, or
by failure to update the software as recommended by the Manufacturer.
Guarantee
All above is for reference only, please see the subject products.
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.Any Changes or modications not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment. This
equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment o and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-ncrease the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.The device has been
evaluated to meet general RF exposure requirement. The device can be used in portable
exposure condition without restriction.

Summary of content (1 pages)