User Manual

Product Introduction Technical Parameters Technical Information Product Configuration Installation Steps
What’s in the box ?
Battery Usage Tips
Tips
01 02 03 04 05 06 07
10 13 15
08
This Sensor supports Command Classes as Below:
* COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
* COMMAND_CLASS_VERSION (V2)
* COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
* COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
* COMMAND_CLASS_POWERLEVEL (V1)
* COMMAND_CLASS_BATTERY (V1)
* COMMAND_CLASS_ASSOCIATION (V2)
* COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)
* COMMAND_CLASS_WAKE_UP (V2)
* COMMAND_CLASS_SWITCH_BINARY (V1)
* COMMAND_CLASS_NOTIFICATION (V6)
* COMMAND_CLASS_CONFIGURATION (V1)
*COMMAND_CLASS_INDICATOR (V1)
Command Classes
LED Color Indicator
Network Configuration
Add Siren Alarm to Z-Wave Network
The siren alarm can be included to the Z-Wave network by
pressing on the code button.
1. Disassemble the siren alarm and insert the battery into the
siren alarm. Make sure the device is located within the direct
range of the controller.
2. Set the controller into the learning mode (see main
controller's operating manual).
3. Quickly, triple click the code button, LED light will flash red
for 5 times.
4. Siren alarm will be detected and included in the Z-Wave
network.
5. Wait for the main controller to configure the siren alarm.
Note: Power to the code, the device is plugged into the power 20S can not have
any operation!
Remove Siren alarm from Z-Wave Network
1. Make sure the sensor is connected to power source.
01
2. Set the main controller into the learning mode (see main
controller'soperating manual).
3. Quickly, triple click the code button,LED light will flash red for
5 times.
4. Wait for the main controller to delete the sensor.
Restore the Sensor to Factory Default Settings
Reset procedure will delete all information on the Z-Wave
network and Z-Wave controller or Z-Wave Gateway, and restore
the sensor to factory default settings.
1. Remove the device cover.
2. Make sure the sensor is powered.
3. Press and hold the button for 10 seconds, led will blink once.
4. Release the button.
Note: restore factory settings in the process, do not power off.
Associations
This Siren supports 3 groups; each group supports max 5 associated
nodes.
This siren can identify some Z-Wave notification sensors such as
Motion Sensor, Door/Window Sensor, Water Leakage Sensor, Smoke
Sensor and so on. If these sensors associate this siren to their lifeline
group or other group that supports NOTIFICATION_REPORT, the siren
will play different music when sensor is triggered.
GROUP 1 is lifeline service that assigned to Siren status. It enables
the Siren to send reports and reading to Z-Wave Controller or Z-Wave
Gateway whenever the sensor is triggered. This Group
Support:SWITCH_BINARY_REPORT,
NOTIFICATION_REPORT,BATTERY_REPORT,
DEVICE_RESET_LOCALLY_NOTIFICATION
GROUP 2 allows for Send Binary Switch Report to associated devices
in this group. This Group Support:SWITCH_BINARY_REPORT
GROUP 3 allows for Send Notification to associated devices in this
group. This Group Support:NOTIFICATION_REPORT
NOTE: Association allows for direct communication between Z-Wave network
devices. Main controller does not take part in such communication.
Advanced Configuration
1. Configure Alarm Music Volume
This parameter defines the output volume when siren plays door bell music.
Door Bell music volume is divided into 3 stages, Low (Parameter is set to ‘1’),
Middle (Parameter is set to ‘2’), High (Parameter is set to ‘3’). Default value is ‘3’.
Parameter Number : 1
Parameter Size: 1
Available Settings: 1-3
Default Setting: 3
2. Configure Alarm Music Duration Time
This Parameter defines the alarm music duration time when siren receive an
alarm sensor notification report or an alarm command from controller. The
duration time is divided into 5 stages: Siren is not on (Parameter is set to ‘0’), 30
second (Parameter is set to ‘1’), 1 minute (Parameter is set to ‘2’), 5 minute
(Parameter is set to ‘3’) and Siren is always on until battery is dead (Parameter is
set to ‘255’). Default value is ‘2’.
Parameter Number : 2
Parameter Size: 1
Available Settings: 0-3,255
Default Setting: 2
3. Configuring Door Bell Music Duration Time
This parameter defines the door bell music duration time when siren receives a
door/window sensor notification report. The door bell music will be played
14
always if this parameter is set to ‘255’. The door bell music will not be played if
this parameter is set to ‘0’. Other values are the door bell music playing duration
time. Unit: Time.
Parameter Number : 3
Parameter Size: 1
Available Settings: 0-255
Default Setting: 1
4. Configure Door Bell Music Volume
This parameter defines the output volume when siren plays alarm music. Door
Bellmusic volume is divided into 3 stages, Low (Parameter is set to ‘1’), Middle
(Parameter is set to ‘2’), High (Parameter is set to ‘3’). Default value is ‘1’.
Parameter Number : 4
Parameter Size: 1
Available Settings: 1-3
Default Setting: 1
5. Configure Alarm Music Index
This parameter defines the alarm music index for siren play different music
when alarm occurs. There are 10 different music for user selection.
Parameter Number : 5
Parameter Size: 1
Available Settings: 1-10
Default Setting: 10
6. Configure Door Bell Music Index
This parameter defines the door bell music index for siren play different music
when alarm occurs. There are 10 different music for user selection.
Parameter Number : 6
Parameter Size: 1
Available Settings: 1-10
Default Setting: 9
7. Configure Default Siren On Mode
This parameter defines the default music index, volume and the duration time
for siren on. This parameter can be selected between ALARM MUSIC and DOOR
BELL MUSIC. The settings for ALARM MUSIC MODE defines by Param #1, #2 and
#5. Thesettings for DOOR BELL MUSIC MODE defines by Param #3, #4 and #6.
If parameter set to ‘1’, siren will select ALARM MUSIC MODE to play music;
If parameter set to ‘2’, siren will select DOOR BELL MUSIC MODE to play music;
Parameter Number : 7
Parameter Size: 1
Available Settings: 1-2
Default Setting: 1
8. Configure Alarm Led Enable
This parameter defines the default led enable status when siren is on for ALARM
MUSIC MODE.
If parameter is set to ‘0’, led will be disable.
If parameter is set ‘1’, led will be enable. When siren is on, the led will blink.
Parameter Number : 8
Parameter Size: 1
Available Settings: 0,1
Default Setting: 1
9. Configure Door Bell Led Enable
This parameter defines the default led enable status when siren is on for DOOR
BELL
MUSIC MODE.
If parameter is set to ‘0’, led will be disable.
If parameter is set t0 ‘1’, led will be enable. When siren is on, the led will blink.
Parameter Number : 9
Parameter Size: 1
Available Settings: 0,1
Default Setting: 0
Command Class Interact
Binary SwitchCommand Class
Siren can be turned on and off by COMMAND_CLASS_SWITCH_
BINARY Which music will be play by siren is decided by advance configuration
parameter #5. When Siren stop play alarm music, it will send a
SWITCH_BINARY_REPORT = 0x00 to controller.
Siren Alarm On:
Command Class:COMMAND_CLASS_SWITCH_BINARY
Command: SWITCH_BINARY_SEND
Value: 0xFF
Siren Alarm Off:
Command Class: COMMAND_CLASS_SWITCH_BINARY
Command: SWITCH_BINARY_SEND
Value: 0x00
Basic Command Class
The Functions of BASIC_SET = 0x00 And BASIC_SET = 0xFF are same to Binary
Switch Command Class.
Indicator Command Class
The INDICATOR_SET Value is indicated that which music will be played. For
example:INDICATOR_SET = 0x01, Siren will play the first music.See the Table As
Blow:
Command Music Index in Memery Playing Volume And Time
INDICATOR _SET = 0x01 1 Defined By Param #3, #4
INDICATOR _SET = 0x02 2 Defined By Param #3, #4
INDICATOR _SET = 0x03 3 Defined By Param #3, #4
INDICATOR _SET = 0x04 4 Defined By Param #3, #4
INDICATOR _SET = 0x05 5 Defined By Param #3, #4
INDICATOR _SET = 0x06 6 Defined By Param #3, #4
INDICATOR _SET = 0x07 7 Defined By Param #3, #4
INDICATOR _SET = 0x08 8 Defined By Param #3, #4
INDICATOR _SET = 0x09 9 Defined By Param #3, #4
INDICATOR _SET = 0x0A 10 Defined By Param #3, #4
Other INDICATOR_SET values are invalid for this siren.
Notification Command Class
If Siren receives a command from associated devices or controller to play any
music, siren will send an active notification to controller. If Siren stops play
music, it will send a no active notification to controller.
Siren Active Notification Report:
Command Class : COMMAND_CLASS_NOTIFICATION
Command: NOTIFICATION_REPORT
Notification Type: NOTIFICATION_TYPE_SIREN
Event: NOTIFICATION_EVENT_SIREN_ACTIVE
Siren No Active Notification Report:
Command Class : COMMAND_CLASS_NOTIFICATION
Command: NOTIFICATION_REPORT
Notification Type: NOTIFICATION_TYPE_SIREN
Event: NOTIFICATION_EVENT_SIREN_NO_EVENT
Battery Check Command
The users can also enquire the battery status of the siren by sending
BATTERY_GET command. Once the siren receivers the command, it will return
BATTERY_REPORT command. The siren will send BATTERY_LEVEL = 0xFF
command to the Z‐Wave Controller to inform that the siren is in dead battery
status, otherwise BATTERY_LEVEL value range is 0% to 100%.
09 11 12 15
22
17
Install the battery
Close the siren alarm
16
LED Color
Led Display Status
Description
Red
Blink 5 Times
(1s Interval)
Blink 5 Times
(500msInterval)
Blink 5 Times
(300msInterval)
Blink 1 Time
Turn on with rotation
Power on and Not Add in Z-Wave
Network
Press Button tripled, Adding siren in
a Z-WaveNetwork or Send Node Info.
Power on and Already Add in a Z-
Wave Network
Press the Button Long Time, Reset
the Plug torestore default settings
Alarm on
Power supply: CR123A x 2
External power supply: Mini USB 6V, 0.5A(voltage
should not be too large, may burn the equipment, if
less than 6V, the device will report low current)
Stand-by time: 1 year
Radio Frequency: 868.4MHz EU; 908.4MHz US
921.4 MHZ AU; 869.2 MHZ RU
Compatible with 300 series and 500 series
Easy installation on wall or any surface
10 sound can be select
Range:up to 80m outdoor; up to 40m indoor
Power Consumption: 2W
Max Current: 35mA (In Radio Transmitter Mode)
500mA (In Siren On and Max Volume Mode)
Radio Protocol: Z-Wave
Sound intensity: 100 dB
Operation temperature: 0~40
Storage temperature: 0~60
Dimension:(D x W x H): 68mm x 68mm x 33mm
Siren alarm is an intelligent device that can be controlled
remotely by the radio frequency. Siren alarm send messages via
Z-Wave network to the Z-Wave main controller. In the Z-Wave
network communications, Siren alarm can be connected to any
Z-Wave main controller, Different countries or areas, the radio
frequencyof the Z-Wave network is different.In the
communication between the Siren alarm and Z-Wave main
controller, the siren alarm can both send and receive messages.
When press the code button of siren alarm, it will send message
to the Z-Wave main controller, the Z-Wave main controller can
display the on/off status of the siren alarm; when the siren
alarm receives messages from theZ-Wave main controller, the
siren alarmwill be triggered. The siren alarm is battery powered,
small and easily install. When sirenalarm is working, LED light
will flash, and there will be alarm sound at the same time. The
sound is not lower than 100 decibels.
Siren alarm 1pc
Battery 2pcs
Screw 1pc
Screw stopper 1pc
Double-side adhesive 1pc
User manual 1pc
Screw
Screw stopper
Sticker
Mounting hole
Battery
The Code button
Siren
USB External
power supply
Cover
1. Cover Installation
Method 1:
1. Secure the screw into the wall
and side the siren over it making
sure the screw head goes into
the Mounting hole.
2. Pull the siren down slightly
and screw will lock in place.
Method 2:
Fix the siren alarm with sticker.
2. Battery Installation
Open the siren alarm
1. When install the siren alarm, please avoid the noisy places.
2. Please install somewhere easy to find.
3. Do not install in a ventilated position to affect the effect of
the siren alarm.
4. Do not install at a wet place to prevent the siren alarm from
damaging.
5. When the siren alarms, it would sound and the led would
flash red lights.
6. Association allows for direct communication between Z-
Wave network devices. Main controller does not take part in
such communication. Using this mechanism, siren alarm may
communicate with other devices even when the main
controller is damaged.
Battery life of the siren alarm is approximately 1years at factory
default settings. The current battery level is displayed in the Z-
Wave main controller. Red battery icon means the battery
needs replaced.
Note: Siren alarm is battery powered. Using batteries other than specified may
result in explosion. Dispose of properly, please observe environmental
protection rules.
External power usage hints
External power interface is Mini USB socket adapter with 6V,
0.5A specification. If the voltage is in the 4.5 – 6V range the
device will work but may report low power.
When the siren alarm triggered, it will make alarm sound
and LED light flashat the same time.
When the other sensor is triggered, the siren alarm can
associate with the sensors through the Z-Wave network.
Siren alarm can be controlled remotely via mobile phone
app.
Compatible with any Z-Wave controller.
Thank you for your support
Please read the user manual carefully before operating.
Please keep the user manual for future reference.
Siren Alarm
User Manual
Installation example
1.The Guarantee is provided by our company (hereinafter “Manufacture” )
2.The Manufacturer is responsible for equipment malfunction resulting from
physical defects (manufacturing or material) for 12 months from the date of its
purchasing.
3.During the Guarantee period, the Manufacturer shall repair or replace any
defects, free of charge.
4.In special cases, when the device cannot be replaced with the device of the
same type (e.g. the device is no longer available in the commercial offer), the
Manufacturer may replace it with a different device which has similar technical
parameters as the faulty one. Such activity shall be considered as fulfilling the
obligations of the Manufacturer. The Manufacturer shall not refund money paid
for the device.
5.The guarantee shall not cover:
a. mechanical damages (cracks, fractures, cuts, abrasions, physical
deformations caused by impact, falling or dropping the device or other object,
improper use or not observing the operating manual);
b. damages resulting from external causes, e.g.: flood, storm, fire, lightning,
natural disasters, earthquakes, war, civil disturbance, force majeure, unforeseen
accidents, theft, water damage, liquid leakage ,battery spill, weather conditions,
sunlight, sand, moisture, high or low temperature, air pollution
c. damages caused by malfunctioning software, attack of a computer virus, or
by failure to update the software as recommended by the Manufacturer.