Product : MM002-xx-US Doc : Datasheet Reference : datasheet_MM002-xx-US History : V0.
Table of contents Disclaimer .................................................................................................3 Document history .........................................................................................5 References .................................................................................................5 Purpose .................................................................................................... 5 Certification .........................................
Disclaimer 1. This document is provided for reference purposes only so that Nemeus customers may select the appropriate products for their use. Nemeus neither makes warranties or representation with respect to the accuracy or completeness of the information contained in this document, nor grants any license to any intellectual property rights or any other rights of Nemeus or any third party with respect to the information in this document. 2.
Document history Version Date Author Comments V0.1 19/11/2018 Gilles Ronco Initial Table 1 : Document versions References [1] Semtech – Datasheet SX1272 Purpose This document is dedicated to NEMEUS MM002-xx-US radio module.
Module features The MM002-xx-US is a long range / low power wireless module operating in US/ CANADA ISM band (915Mhz). With interferers’ robustness and low power consumption, it is the best solution for applications requiring long range, maximum battery lifetime and secure radio link. This module integrates a SX1272 LoRaTM transceiver from Semtech and a low power ARM Cortex M3 controller.
General description The MM002-xx-US module is a long range, high-performance, solution for wireless bi-directional communication using patented LoRa™ technology from Semtech company. It operates in the US/CANADA 915 MHz frequency band and includes all necessary components for an easy integration in existing systems.
Module pins diagram The following figure gives the top view of the MM002-xx-EU module. Pad size on MM002: 0.8x1mm Footprint recommendations: TOP VIEW Footprint for all pads: 0.9x1.
Design recommendations With 4 layers PCB design, it is recommended to keep the 1st layer under the module without any layout and have a full ground plane on the 2nd layer (at least under the right part of the module : under RF transceiver part). Module Ground Plane Power Signals (or ground plane) Figure 2 : 4 layer PCB design All ground pads must be connected to ground. In case of ground planes on different layers, these one must be connected together through via.
T(s) 0 Temp(°C 25 ) 15 37,5 195 217,5 270 300 25 100 240 240 120 100 Reflow profile (°C) 300 225 150 75 0 0 15 37.5 195 217.5 270 300 Embedded software By default, the module is provided with AT command software version allowing to control it from an external micro-controller through an UART interface.
Module pinning description Module pins functions can be configured by specific software. Description of possible configurations is provided at the end of this specification for reference. Whatever the pins configuration made by embedded software, some of them have unique functionality.
Default pinning configuration (modem controlled by AT command) With AT command modem software, only few pins are configured and used. Other ones have no specific functions and are not driven by embedded software. These extra pins must be kept Unconnected. Default modem software manages UART2 to communicate with application processor or similar. In this configuration following pins are configured.
Electrical characteristics Absolute maximum rating Symbol VCC Description Min Max Unit Module power supply 2.7 3.3 V -40 +85 °C - +10 dBm Temperature PwIN RF input power Operating range Symbol VCC Description Min Typ. Max Unit Module power supply 2.7 3.0 3.
Current consumption Three states must be considered for current consumption: • Modem module in IDLE mode with RTC like function • Modem module in TX mode • Modem module in RX mode Conditions: VCC =3V, T=25°C Symbol Description Conditions ICC_ IDLE Min Typ (LoRa) Max Unit - < 2uA - uA ICC_TX_20dB Modem in TX Tx power mode = +20dBm - 122 - mA ICC_RX Modem in RX mode - 13 - mA Available Pin configuration Based on STM32L15x uC family, major part of module pins can be configured by
Functions class Modem_JTAG Modem PWRUP Sensors pins 1/2 lun e PAD na me Functions Default function (mod em only mode ) Nam e pins MCU 12 JTMS-SWDAT JTMS SWDAT 11 JTCK-SWCLK JTCK SWCLK PA1 4 Reset/ Boot Mod e JTAG/ SW USAR T1 USAR T2 SPI1 I2C1 ADC WKU P GPIO PA1 3 GPIO #1 GPIO #2 JTAG/ SW 10 JTDI JTDI PA1 5 GPIO #3 9 JTDO JTDO PB3 GPIO #4 8 NJTRST NJTRST PB4 GPIO #5 2 NRST NRST NRS T NRESET 5 NC NC BOO T0 BOO T0 25 WKUP1/RTC_TAMP2/ TIM2_CH1_ETR/ TIM5_CH1/
23 Sensors pins TIM2_CH4/TIM5_CH4/ TIM9_CH2/ USART2_RX/ LCD_SEG2/ ADC_IN3/ COMP1_INP/ OPAMP1_VOUT 7 USART1 _TX PB 6 6 USART1 _RX PB 7 TIM4_CH3/TIM10_CH1/ I2C1_SCL/LCD_SEG16 I2C1_S CL PB 8 TIM4_CH4/TIM11_CH1/ I2C1_SDA/LCD_COM3 I2C1_S DA 4 3 22 USAR T#2 ADC #4 GPIO #9 GPIO #10 USAR T#1 GPIO #11 GPIO #12 I2C #1 SPI1_N SS PB 9 GPIO #13 PA 4 GPIO #14 20 SPI1_SC K PA 5 21 SPI_MISO PA 6 GPIO #16 19 SPI1_MOSI PA 7 GPIO #17 USB PA 11 GPIO #18 14 13 Ground PA 3 USART1_CT
Supply RF 27 17 VCC Analog and digital supply ANT RF antenna input/ output 17
FCC REGULATORY APPROVAL The MM002-LS-US module has received Federal Communications Commission (FCC) CFR47 Telecommunications, Part 15 Subpart C “Intentional Radiators” modular approval in accordance with Part 15.212 Modular Transmitter approval. Modular approval allows the end user to integrate the MM002-L-US module into a finished product without obtaining subsequent and separate FCC approvals for intentional radiation, provided no changes or modifications are made to the module circuitry.
The user's manual for the finished product should include the following statements: Any changes or modifications to this equipment not expressly approved by [Name_of_OEM/Integrator] may cause harmful interference and void the user’s authority to operate this equipment. RF EXPOSURE The FCC grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators.
CANADA (ISED) REGULATORY APPROVAL The MM002-LS-US module has been certified for use in Canada under Industry Canada (IC) Radio Standards Specification (RSS) RSS-247 and RSS-Gen. Modular approval permits the installation of a module in a host device without the need to recertify the device. This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 1.