Display for solar regulator MPPT SC300M mod.: DT001 www.ndsenergy.it ~ e-mail: commer@ndsenergy.
CONTENTS 1.Description 1.1 Main functions 2.INSIDE THE BOX 2.1 Device components 2.2 Accessories for installation 3.INSTRUCTIONS FOR INSTALLATION 3.1 Installing device DT001 4.GETTING STARTED 4.1 Using Touch Screen 4.2 Initial settings 5.OPERATION 5.1 Main screen 5.2 symbols explanation 5.3 Visualization of the state of charge(SoC) 6.MANAGEMENT OF THE BATTERIES 6.1 Charge of the Engine battery 7.Setting Menu (Setting Button) 7.1 Setting Button 8.ADDITIONAL FUNCTIONS 8.2 Turn off display 9.
1. DESCRIPTION DT001 is the diplay for the solar regulator SC300M for solar panels with MPPT technology. Thanks to the colored touch screen display, the device shows all the charging data of the service battery and of the engine battery, it shows also the status of the photovoltaic panels connected to the regulator. 1.
2. INSIDE THE BOX 10.1 Warranty coupon Make sure the box includes the following components: Display 'DT001' Communication cable 'DT001' Assembling screw kit Mod. .................................... Serial n................................................................................. Date of purchase .................................................. The items provided are designed for this device exclusively and are not compati ble with other devices. Surname ................................
2.1 Device components 10. WARRANTY The manufacturer shall guarantee the proper functioning of the DT001 and undertake to make free replacement of partswhich should be deteriorated due to defects in construction within 24 months from the date of purchase, as evidenced by the validation slip (to be filled in each part and returned to the manufacturer). The defects resulting from improper installation, use,tampering or negligence shall not be covered by warranty.
3. INSTRUCTIONS FOR INSTALLATION 7. Setting Menu (Setting Button) In order to install the device properly, Follow the instructions below 7.1 Setting button 3.1 Installing the device DT001: Tapping the Settings button it is possible to access the initial setup menu, ie to the series of screens that appear at the first installation and that are always consultable and modifiable. 1. Disassemble the display frame of the DT001 8. ADDITIONAL FUNCTIONS 8.
6. MANAGEMENT OF THE BATTERIES 6.1 Charge of the engine battery This feature is critical for storage periods, in fact, even after long stops avoids being with the engine empty battery that does not start anymore. The SC300M regulator can automatically charge the engine battery only when it is actually needed, and there are the following conditions: - Engine battery below 12.5V - The service battery must be fully charged - The photovoltaic panel/s must be able to supply energy.
5.3 Visualization of the State of Charge (SoC) 4. GETTING STARTED 4.1 USING THE TOUCH SCREEN The DT001 touch screen allows you to interact with the device by selecting the several functions easily. For the proper use of the touch screen, follow the instructions below: Do not exercise too much pressure with your fingers on the display surface and do not use sharp objects. By doing so, you may damage the device or cause it to malfunction.
5.2 Symbols explanation SYMBOL 4.2 INITIAL SETTINGS Engine battery not connected or not in charge Switching the device on When the communication cable is connected, the display turns on and the initial screen appears, with the "SUN CONTROL" writing which will keep displaying until the device has not received the first data from the SC300M. Engine battery in charge. Initial settings Once the data have been received, the display will show the connected batteries’ data setup screen.
Photovoltaic modules setting: 5. OPERATION Allows to set the power of the panels connected to the 2 inputs of the SC300M . 5.1 Main screen The proposed value is 100Wp per panel, but if you have only one panel, you can reset the value of power to Zero PF2 by clicking on this button under the corresponding white box. In the main screen of DT001 it is possible to monitor all information about the battery status, tension, current, SoC, date and time and status of the solar panels. .